One-year clinical evaluation of two composite materials used for anterior class V restorations

被引:8
|
作者
Sakrana, AA
Tanoue, N
Kawasaki, K
Matsumura, H
机构
[1] Nagasaki Univ, Hosp Dent, Dept Gen Dent, Nagasaki 8528588, Japan
[2] Mansoura Univ, Fac Dent, Dept Crown & Bridge Prosthodont, Mansoura, Egypt
[3] Nihon Univ, Sch Dent, Dept Prosthodont, Tokyo 101, Japan
关键词
class V restoration; clinical evaluation; composite; United States Public Health Service criteria;
D O I
10.1111/j.1365-2842.2004.01333.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of the current study was to evaluate the clinical performance of two composite materials used for filling anterior cavity preparations. A total of 100 class V cavities of anterior tooth were restored with two different composite materials (Palfique Estelite and Palfique Toughwell, 50 cavities each, respectively) in combination with the same bonding agent (Mac Bond II). Colour match, cavosurface marginal discolouration, recurrent caries, wear, marginal integrity and surface texture were evaluated clinically for all restorations on the basis of the United States Public Health Service (USPHS) criteria immediately after insertion (baseline), after 6 months and after 1 year. In the comparison of baseline to 1-year evaluation, the Palfique Toughwell material showed significant changes in all factors except recurrent caries. The Palfique Estelite material, however, showed neither significant cavosurface marginal discolouration nor recurrent caries. No significant difference (P > 0b05) was observed between the two materials in clinical performance after 1 year, with the exception of caries rate, which was found to be significantly lower in the Palfique Estelite material. It was concluded that both composites were clinically reliable materials when used for anterior class V restorations.
引用
收藏
页码:985 / 990
页数:6
相关论文
共 42 条
  • [21] Two-year clinical evaluation of composite resins in non-carious cervical lesions
    Wei Qin
    Zhi Song
    Yun-Yao Ye
    Zheng-Mei Lin
    Clinical Oral Investigations, 2013, 17 : 799 - 804
  • [22] Clinical Evaluation of a Two-step Etch&Rinse and a Two-step Self-etch Adhesive System in Class II Restorations: Two-year Results
    Ermis, R. B.
    Kam, O.
    Celik, E. U.
    Temel, U. B.
    OPERATIVE DENTISTRY, 2009, 34 (06) : 656 - 663
  • [23] One-year clinical evaluation of a flowable resin liner associated with a microhybrid resin in noncarious cervical lesions
    Alessandro D. Loguercio
    Camila Zago
    Kiandra Leal
    Neila Rosane Ribeiro
    Alessandra Reis
    Clinical Oral Investigations, 2005, 9 : 18 - 20
  • [24] One-year clinical evaluation of a flowable resin liner associated with a microhybrid resin in noncarious cervical lesions
    Loguercio, AD
    Zago, C
    Leal, K
    Ribeiro, NR
    Reis, A
    CLINICAL ORAL INVESTIGATIONS, 2005, 9 (01) : 18 - 20
  • [25] One-year clinical evaluation of a two-step self-etch adhesive with and without additional enamel etching technique in cervical lesions
    Ozel, E.
    Say, E. C.
    Yurdaguven, H.
    Soyman, M.
    AUSTRALIAN DENTAL JOURNAL, 2010, 55 (02) : 156 - 161
  • [26] Comparison between Different Bulk-Fill and Incremental Composite Materials Used for Class II Restorations in Primary and Permanent Teeth: In Vitro Assessments
    Ibrahim, Maria Salem
    Alkhalefah, Ahmed Saleh
    Alsaghirat, Abdullah Ali
    Alburayh, Read Ahmed
    Alabdullah, Nezar Ahmed
    MATERIALS, 2023, 16 (20)
  • [27] Longevity of direct diastema closure and recontouring restorations with resin composites in maxillary anterior teeth: A 4-year clinical evaluation
    Korkut, Bora
    Turkmen, Cafer
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (04) : 590 - 604
  • [28] A 3-year clinical evaluation of endocrown restorations with two different materials using the computer-aided design/ computer-aided manufacture system
    Keskin, Simge Canatan
    Sakar, Asli
    Bolay, Sukran
    JOURNAL OF DENTISTRY, 2024, 151
  • [29] A Two-year Clinical Comparison of Three Different Restorative Materials in Class II Cavities
    Balkaya, H.
    Arslan, S.
    OPERATIVE DENTISTRY, 2020, 45 (01) : E32 - E42
  • [30] Two-year clinical evaluation of ormocer and nanofill composite with and without a flowable liner
    Efes, BG
    Dörter, C
    Gömec, Y
    Koray, F
    JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (02) : 119 - 126