Quality control in PET/CT systems: experiences and requirements

被引:3
作者
Geworski, Lilli [1 ]
Karwarth, Cornelia [2 ]
Fitz, Eduard
Plotkin, Michail [2 ]
Knoop, Bernd
机构
[1] Hannover Med Sch, Med Phys Zentrum Radiol OE 8253, D-30625 Hannover, Germany
[2] Charite Univ Med Berlin, Klin Nukl Med, Berlin, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2010年 / 20卷 / 01期
关键词
PET/CT; routine control; acceptance test; off-set; SCANNER;
D O I
10.1016/j.zemedi.2009.10.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Today, in most cases PET examinations are performed using PET/CT hybrid systems. While acceptance testing and routine control of the basic modalities PET and CT, respectively, are described by appropriate regulations, corresponding instructions with regard to the interface connecting both are still missing. This interface includes the adjustment of gantries and patient bed to each other as well as the energy scaling of attenuation coefficients from CT energy to 511 keV. Measurements checking the mechanical adjustment (determination of off-set parameters) are performed following manufacturer's recommendation, with a typical frequency twice a year. On a Biograph 16 (Siemens, Inc.), these measurements were systematically extended to a weekly frequency over an observation period of 10 months, supplemented by measurements with additional load to the patient bed (up to 135 kg), and different vertical bed positions. The results show, that for the construction tested additional off-set measurements for routine control extending well beyond manufacturer's recommendation are not necessary. The energy scaling of attenuation coefficients is depending on methodological aspects and software implementation, and therefore is not part of routine control. On the contrary, the development of appropriate methods for acceptance testing to assess and to determine the mechanical adjustment in all its degrees of freedom as well as the accuracy of attenuation corrected emission data is urgently needed.
引用
收藏
页码:46 / 50
页数:5
相关论文
共 11 条
[1]  
[Anonymous], 6122326 DIN EN
[2]  
Beyer T, 2000, J NUCL MED, V41, P1369
[3]  
*BGBI IS, 1987, 114 BGBI IS
[4]  
*BGBI IS, 2002, 1714 BGBI IS
[5]  
*DIN, 2004, 68554 DIN
[6]  
*DIN EN, 2000, 616751 DIN EN
[7]  
*DIN EN, 6122335 DIN EN
[8]  
GEWORSKI L, 1999, NUKLEARMEDIZINER, V22, P23
[9]  
Geworski L, 2003, EMPFEHLUNGEN QUALITA, P217
[10]   Attenuation correction for a combined 3D PET/CT scanner [J].
Kinahan, PE ;
Townsend, DW ;
Beyer, T ;
Sashin, D .
MEDICAL PHYSICS, 1998, 25 (10) :2046-2053