Randomized clinical trial comparing radioisotope occult lesion localization and wire-guided excision for biopsy of occult breast lesions

被引:112
|
作者
Rampaul, RS [1 ]
Bagnall, M [1 ]
Burrell, H [1 ]
Pinder, SE [1 ]
Evans, AJ [1 ]
Macmillan, RD [1 ]
机构
[1] City Hosp, Nottingham Breast Inst, Nottingham NG1 5PB, England
关键词
D O I
10.1002/bjs.4801
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Accurate localization of impalpable breast lesions that require biopsy is important. This randomized trial compared radioisotope occult lesion localization (ROLL) with the standard hooked-wire technique. Methods: Ninety-five patients were randomized to receive either ROLL or wire localization of an occult breast lesion. Correct placement of isotope was confirmed by mammography and a hand-held gamma probe was used to guide the surgical excision. Radiological, surgical and pathological data were compared for accuracy, duration and ease of technique, and histopathological. diagnosis. Procedure-related pain was also assessed. Results: Of the 95 patients entered, 48 were randomized to ROLL and 47 to mire localization. Two ROLL procedures failed. Marking was accurate in 46 of 48 ROLL procedures and 44 of 47 of wire localizations (P = 0.242). Difficulty in localization (Likert score 2.6 for ROLL versus 4.4 for wire localization; P < 0.001) and the degree of surgical difficulty (2.6 versus 4.0; P < 0.001) were significantly less for ROLL. ROLL was associated with less pain (score 2.7 versus 3.6; P = 0.012). There were no significant differences in mean duration of operation, specimen weight, need for intraoperative re-excision or second therapeutic operation. Conclusion: ROLL and wire-guided localization were similarly effective for breast biopsy, but ROLL was easier for both radiologist and surgeon, and less painful for the patient.
引用
收藏
页码:1575 / 1577
页数:3
相关论文
共 50 条
  • [41] Cosmetic results after wire-guided biopsy of benign breast lesions
    Saarela, AO
    Kiviniemi, HO
    Rissanen, TJ
    Haukipuro, K
    Kaarela, O
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 187 (06) : 610 - 615
  • [42] Randomized controlled trial comparing magnetic marker localization (MaMaLoc) with wire-guided localization in the treatment of early-stage breast cancer
    Struik, Gerson M.
    Schermers, Bram
    Mares, Ingeborg
    Lont, Harold E.
    Bradshaw, Jennifer W.
    ten Haken, Bernard
    Ruers, Theo J. M.
    Mourik, Jurgen E. M.
    Birnie, Erwin
    Klem, Taco M. A. L.
    BREAST JOURNAL, 2021, 27 (08): : 638 - 650
  • [43] Radioguided Occult Lesion Localization (ROLL) of the Nonpalpable Suspicious Breast Lesions
    Sager, S.
    Halac, M.
    Sayman, H.
    Kabasakal, L.
    Kanmaz, B.
    Sonmezoglu, K.
    Onsel, C.
    Uslu, I.
    Aydogan, F.
    Yilmaz, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S136 - S136
  • [44] NEEDLE LOCALIZATION BIOPSY OF OCCULT LESIONS OF THE BREAST - EXPERIENCE IN 199 CASES
    YANKASKAS, BC
    KNELSON, MH
    ABERNETHY, ML
    CUTTINO, JT
    CLARK, RL
    INVESTIGATIVE RADIOLOGY, 1988, 23 (10) : 729 - 733
  • [45] Impact of radioguided occult lesion localization on the correct excision of malignant breast lesions: effect of histology and tumor size
    John Patrick Pilkington Woll
    Montserrat Cortés Romera
    Ana Maria García Vicente
    Beatriz González García
    Margarita Delgado Portela
    Jose Manuel Cordero García
    Ricardo Pardo García
    Ceferino Molino Trinidad
    Angel Maria Soriano Castrejón
    Annals of Nuclear Medicine, 2011, 25 : 197 - 203
  • [46] Impact of radioguided occult lesion localization on the correct excision of malignant breast lesions: effect of histology and tumor size
    Pilkington Woll, John Patrick
    Cortes Romera, Montserrat
    Garcia Vicente, Ana Maria
    Gonzalez Garcia, Beatriz
    Delgado Portela, Margarita
    Cordero Garcia, Jose Manuel
    Pardo Garcia, Ricardo
    Molino Trinidad, Ceferino
    Soriano Castrejon, Angel Maria
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (03) : 197 - 203
  • [47] Magnetic resonance imaging-guided core needle biopsy and needle localized excision of occult breast lesions
    Smith, LF
    Henry-Tillman, R
    Mancino, AT
    Johnson, A
    Jones, MP
    Westbrook, KC
    Harms, S
    Klimberg, VS
    AMERICAN JOURNAL OF SURGERY, 2001, 182 (04): : 414 - 418
  • [48] Radio-guided Occult Lesion Localisation (ROLL) Versus Wire-guided Localisation (WGL) in Breast Conserving Surgery for Non-palpable Breast Cancer (ROLL Study): a Randomised Clinical Multicenter Trial
    Postma, E.
    Verkooijen, H. M.
    van Esser, S. E.
    Hobbelink, M. G.
    van der Schelling, G. P.
    Koelemij, R.
    Witkamp, A. J.
    Mali, W.
    van den Bosch, M. A. A. J.
    van Hillegersberg, R.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S105 - S105
  • [49] Comparing radioguided occult lesion localization (ROLL) vs wire guide (WGL) for impalpable breast cancers.
    Ramesh, HSJ
    Audisio, RA
    Nadeem, R
    Chagla, LS
    Thind, R
    Harris, O
    Desmond, S
    Titterrell, C
    JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (16) : 69S - 69S
  • [50] Identification of a localization wire tip in an occult breast lesion using a handheld magnetometer
    Szynglarewicz, Bartlomiej
    Dolega-Kozierowski, Bartosz
    Szulc, Rafal
    Kasprzak, Piotr
    Matkowski, Rafal
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 30 (03): : 273 - 278