Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result

被引:7
作者
Giorgetti, Assuero [1 ]
Kusch, Annette [1 ]
Casagranda, Mirta [1 ]
Tagliavia, Irene D'Aragona [1 ]
Marzullo, Paolo [1 ]
机构
[1] Monasterio Fdn, Natl Res Council Tuscany Reg, I-56124 Pisa, Italy
关键词
Myocardial perfusion imaging: SPECT; partial volume effect; Tetrofosmin; gated SPECT; EMISSION COMPUTED-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; GATED SPECT; TECHNETIUM-TETROFOSMIN; VENTRICULAR-FUNCTION; RAT-HEART; EXERCISE; STRESS; PROTOCOL; TL-201;
D O I
10.1007/s12350-009-9172-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We previously demonstrated that early (15', T1) post-stress myocardial imaging with Tetrofosmin could be more accurate than standard acquisitions (45', T2) in identifying coronary artery disease. To clarify this phenomenon, 120 subjects (age 61 +/- A 10 years) with both T1 and T2 scans were divided into Group 1 (53/120 pts) with more ischemia at T1 vs T2 imaging (T1-T2SDS a parts per thousand yen 3); Group 2 (67/120 pts) with similar results (T1-T2SDS a parts per thousand currency sign 2). Myocardial areas were categorized as control nonischemic, ischemic, and scarred on the basis of perfusion/contraction properties and coronary anatomy. In each area, regional myocardial count statistic and semiquantitative wall motion/thickening values were obtained. Analysis of T1 and T2 post-stress myocardial counts demonstrated a significant Tetrofosmin wash-out rate that was higher in Group 1 control nonischemic regions (15 +/- A 8% vs 13.6 +/- A 9.6%, P < .02), significantly lower in Group 1 ischemic regions (7 +/- A 10% vs 12.2 +/- A 9.5%, P < .0001), and comparable between scarred areas of the two groups (P = NS). Delta post-stress wall thickening (T1-T2) was lower in Group 1 ischemic regions (-4.5 +/- A 9.15% vs -1.90 +/- A 7.0%, P < .001) and comparable in both control nonischemic and scarred areas of the two groups (P = NS). The clinical result of Tetrofosmin gated-SPECT can be influenced by the post-stress acquisition time because of ischemic-induced regional wall thickening abnormalities and the existence of a differential radiotracer myocardial wash-out.
引用
收藏
页码:276 / 285
页数:10
相关论文
共 27 条
  • [1] Tetrofosmin imaging in the detection of myocardial viability in patients with previous myocardial infarction: Comparison with sestamibi and Tl-201 scintigraphy
    Acampa, W
    Cuocolo, A
    Petretta, M
    Bruno, A
    Castellani, M
    Finzi, A
    Gerundini, P
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (01) : 33 - 40
  • [2] Prolonged impairment of regional contractile function after resolution of exercise-induced angina - Evidence of myocardial stunning in patients with coronary artery disease
    Ambrosio, G
    Betocchi, S
    Pace, L
    Losi, MA
    PerroneFilardi, P
    Soricelli, A
    Piscione, F
    Taube, J
    Squame, F
    Salvatore, M
    Weiss, JL
    Chiariello, M
    [J]. CIRCULATION, 1996, 94 (10) : 2455 - 2464
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Molecular and cellular mechanisms of myocardial stunning
    Bolli, R
    Marbán, E
    [J]. PHYSIOLOGICAL REVIEWS, 1999, 79 (02) : 609 - 634
  • [5] Myocardial stunning induced and detected by adenosine stress perfusion imaging
    Dakik, HA
    Alam, S
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) : 711 - 712
  • [6] Corridor4DM: The Michigan method for quantitative nuclear cardiology
    Ficaro, Edward P.
    Lee, Benjamin C.
    Kritzman, James N.
    Corbett, James R.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 455 - 465
  • [7] Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography
    Germano, G
    Erel, J
    Lewin, H
    Kavanagh, PB
    Berman, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (05) : 1360 - 1367
  • [8] GERMANO G, 1999, CLIN GATED CARDIAC S
  • [9] Baseline/post-nitrate Tc-99m tetrofosmin mismatch for the assessment of myocardial viability in patients with severe left ventricular dysfunction: Comparison with baseline Tc-99m tetrofosmin scintigraphy/FDG PET imaging
    Giorgetti, A
    Marzullo, P
    Sambuceti, G
    Di Quirico, S
    Kusch, A
    Landi, P
    Salvadori, PA
    Pisani, P
    L'abbate, A
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (02) : 142 - 151
  • [10] Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: A multicenter study of the Myoview Imaging Optimization group
    Giorgetti, Assuero
    Rossi, Massimiliano
    Stanislao, Mario
    Valle, Guido
    Bertolaccini, Pietro
    Maneschi, Alberto
    Giubbini, Raffaele
    De Rimini, Maria Luisa
    Mazzanti, Marco
    Cappagli, Mario
    Milan, Elisa
    Volterrani, Duccio
    Marzullo, Paolo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (10) : 1670 - 1675