Stress shielding and bone resorption in shoulder arthroplasty

被引:578
作者
Nagels, J [1 ]
Stokdijk, M [1 ]
Rozing, PM [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, Orthopaed Lab, NL-2300 RC Leiden, Netherlands
关键词
D O I
10.1067/mse.2003.22
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The radiographs of 64 patients with 70 humeral head replacements were reviewed for signs of stress shielding. Of these, 49 were implanted for rheumatoid arthritis and 21 for osteoarthritis. The radiographic follow-up averaged 5.3 years. Measurements of cortex thickness were performed in 4 regions along the stem of the implant, and the differences between the postoperative radiograph and the radiograph at follow-up were calculated. The size of the stem in relation to the diameter of the humerus was calculated with the use of validated measures, resulting in the relative stem size. In 6 patients (9%) a significant reduction in cortical thickness was observed in the proximal-lateral region of the humeral stem, 5 in rheumatoid patients and I in an osteoarthritic patient. In the stress shielding group, the relative stem size was found to be significantly higher than that in the non-stress shielding group (0.58 vs 0.48). Osteoporosis, especially present in rheumatoid arthritis, could well be a risk factor. It was concluded that stress shielding is a long-term complication of shoulder arthroplasty and that the relative stem size is an important factor in its genesis.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 17 条
  • [1] [Anonymous], 1986, LAW BONE REMODELLING
  • [2] The pathology of total joint arthroplasty - II. Mechanisms of implant failure
    Bauer, TW
    Schils, J
    [J]. SKELETAL RADIOLOGY, 1999, 28 (09) : 483 - 497
  • [3] Dujovne A R, 1993, J Arthroplasty, V8, P7, DOI 10.1016/S0883-5403(06)80102-6
  • [4] POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS
    ENGH, CA
    BOBYN, JD
    GLASSMAN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 45 - 55
  • [5] ENGH CA, 1988, CLIN ORTHOP RELAT R, P7
  • [6] HARRIS WH, 1992, CLIN ORTHOP RELAT R, P120
  • [7] HUISKES R, 1990, CLIN ORTHOP RELAT R, P27
  • [8] Huiskes R, 1980, Acta Orthop Scand Suppl, V185, P1
  • [9] HUISKES R, 1992, CLIN ORTHOP RELAT R, P124
  • [10] Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling
    Kerner, J
    Huiskes, R
    van Lenthe, GH
    Weinans, H
    van Rietbergen, B
    Engh, CA
    Amis, AA
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (07) : 695 - 703