Kinetics of fluoride ion release from dental restorative glass ionomer cements: the influence of ultrasound, radiant heat and glass composition

被引:24
作者
Thanjal, N. K. [1 ]
Billington, R. W. [1 ]
Shahid, S. [1 ]
Luo, J. [1 ]
Hill, R. G. [1 ]
Pearson, G. J. [1 ]
机构
[1] Queen Mary Univ London, Barts & London Sch Med & Dent, Dept Dent Phys Sci, London E1 4NS, England
关键词
Compendex;
D O I
10.1007/s10856-009-3901-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To compare the effect of ultrasonic setting with self curing on fluoride release from conventional and experimental dental glass ionomer cements. To compare hand mixed and capsule mixing and the effect of replacing some of the reactive glass with zirconia. In a novel material which advocated using radiant heat to cure it, to compare the effect of this with ultrasound. To evaluate the effect of ultrasound on a glass ionomer with fluoride in the water but not in the glass. 10 samples of each cement were ultrasonically set for 55 s; 10 controls self cured for 6 min. Each was placed in 10 ml of deionised water which was changed at 1, 3, 7, 14, 21, 28 days. The solution fluoride content was measured using a selective ion electrode. All ultrasound samples released more fluoride than the controls. Release patterns were similar; after a few days, cumulative fluoride was linear with respect to t(1/2). Slope and intercept of linear regression plots increased with ultrasound. With radiant heat the cement released less fluoride than controls. The effect of ultrasound on cement with F in water increased only slope not intercept. Zirconia addition enhances fluoride release although the cement fluorine content is reduced. Comparison of capsule and hand mixing showed no consistent effect on fluoride release. Ultrasound enhances fluoride release from GICs. As heat has an opposite effect the heat from ultrasound is not its only action. The lesser effect on cement with fluoride only in the water indicates that of ultrasound enhances fluoride release from glass.
引用
收藏
页码:589 / 595
页数:7
相关论文
共 20 条
  • [1] ALGERA TJ, 2005, EUR J ORTHODONT, V26, P1
  • [2] BRUNE D, 1982, SCAND J DENT RES, V90, P409
  • [3] FLUORIDE RELEASE FROM GLASS-IONOMER CEMENTS IN DEIONIZED WATER AND ARTIFICIAL SALIVA
    ELMALLAKH, BF
    SARKAR, NK
    [J]. DENTAL MATERIALS, 1990, 6 (02) : 118 - 122
  • [4] HARLE J, 2002, EFFECT ULTRASOUND FI
  • [5] FLUORIDE RELEASE FROM GLASS POLYALKENOATE (IONOMER) CEMENTS
    HILL, RG
    DEBARRA, E
    GRIFFIN, S
    HENN, G
    DEVLIN, J
    HATTON, PV
    BROOK, I
    JOHAL, K
    CRAIG, G
    [J]. ADVANCES IN ENGINEERING MATERIALS, 1995, 99-1 : 315 - 321
  • [6] Jones CS, 1997, J DENT RES, V76, P1073
  • [7] Mechanical properties of glass ionomer cements affected by curing methods
    Kleverlaan, CJ
    van Duinen, RNB
    Feilzer, AJ
    [J]. DENTAL MATERIALS, 2004, 20 (01) : 45 - 50
  • [8] Kinetics of fluoride release from glass components of glass ionomers
    Luo, Jin
    Billington, Richard W.
    Pearson, Gavin J.
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (07) : 495 - 501
  • [9] A COMPARISON OF FLUORIDE RELEASE FROM 3 GLASS IONOMER CEMENTS AND A POLYCARBOXYLATE CEMENT
    MERYON, SD
    SMITH, AJ
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1984, 17 (01) : 16 - 24
  • [10] The influence of ultrasonic setting on fluoride release from glass polyalkenoate cements
    Rushe, N.
    Towler, M. R.
    [J]. JOURNAL OF MATERIALS SCIENCE, 2006, 41 (17) : 5775 - 5777