Atrial mapping during pulmonary vein pacing to detect conduction gaps in a second pulmonary vein isolation procedure

被引:9
作者
Teresa Barrio-Lopez, Maria [1 ,2 ]
Castellanos, Eduardo [1 ]
Ortiz, Mercedes [1 ]
Arceluz, Martin [1 ]
Lazaro, Carla [1 ]
Salas, Jefferson [1 ]
Madero, Sergio [1 ]
Almendral, Jesus [1 ]
机构
[1] Univ CEU San Pablo, Grp HM Hosp, Hosp Monteprincipe, Electrophysiol Lab & Arrhythmia Unit, Madrid, Spain
[2] Hosp Madrid Monteprincipe, Unidad Electrofisiol, Avda Monteprincipe 25, Madrid 28660, Spain
关键词
Atrial fibrillation; Pulmonary vein isolation; Mapping; Conduction gaps; Redo; ABLATION LINE; RADIOFREQUENCY ABLATION; CATHETER ABLATION; END-POINT; FIBRILLATION; TRIAL; IDENTIFICATION;
D O I
10.1007/s10840-018-0371-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Finding the conduction gaps in redo PV isolation procedures is challenging, and several maneuvers have been described. In the present study, we analyze the pace and map (P&M) maneuver [atrial mapping during pulmonary vein (PV) pacing] to locate the gaps in redo PV isolation procedures. Methods Consecutive patients undergoing a second PV isolation procedure at a single institution over a 4-year period were included. For the last 2 years, all the patients (n = 38) studied underwent PV isolation based on the P&M maneuver and were compared to the previous patients (n = 45). The atrial side of the ablation line was mapped with the ablation catheter during PV pacing, and the earliest site was considered a gap site. Results Shorter radiofrequency time was required to obtain PV isolation in the P&M group (485 +/- 374 vs. 864 +/- 544 s; p < 0.001), which remained significant after adjusting for the number of reconnected PVs (p = 0.01). We did not find significant differences in the procedure duration (106 +/- 46 vs. 112 +/- 53 min; p = 0.57) and arrhythmia recurrence during 1-year follow-up (26.6 vs. 28.9%; p = 0.82) after adjusting for several confounding factors (HR 1.32; 95% CI 0.5-3.4; p = 0.57). Conclusions P&M is a simple maneuver to identify the gaps in ablation lines around the PV. It remains efficacious in redo procedures despite the difficulties in localizing the ablation lines performed in the first procedure. The P&M maneuver reduced the radiofrequency time required to isolate the PV without compromising the efficacy.
引用
收藏
页码:195 / 205
页数:11
相关论文
共 20 条
[1]   Identification of conduction gaps in the ablation line during left atrium circumferential ablation:: Facilitation of pulmonary vein disconnection after endpoint modification according to electrogram characteristics [J].
Arena, Angel ;
Atea, Leonardo ;
Datino, Tomas ;
Gonzalez-Torrecilla, Esteban ;
Atienza, Felipe ;
Almendral, Jesus ;
Sanchez, Ana ;
Sanchez, Pedro L. ;
Fernandez-Aviles, Francisco .
HEART RHYTHM, 2008, 5 (07) :994-1002
[2]   Comparison of Radiofrequency Catheter Ablation of Drivers and Circumferential Pulmonary Vein Isolation in Atrial Fibrillation A Noninferiority Randomized Multicenter RADAR-AF Trial [J].
Atienza, Felipe ;
Almendral, Jesus ;
Miguel Ormaetxe, Jose ;
Moya, Angel ;
Daniel Martinez-Alday, Jesus ;
Hernandez-Madrid, Antonio ;
Castellanos, Eduardo ;
Arribas, Fernando ;
Angel Arias, Miguel ;
Tercedor, Luis ;
Peinado, Rafael ;
Fe Arcocha, Maria ;
Ortiz, Mercedes ;
Martinez-Alzamora, Nieves ;
Arenal, Angel ;
Fernandez-Aviles, Francisco ;
Jalife, Jose .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (23) :2455-2467
[3]   Prevalence and Predictors of Complications of Radiofrequency Catheter Ablation for Atrial Fibrillation [J].
Baman, Timir S. ;
Jongnarangsin, Krit ;
Chugh, Aman ;
Suwanagool, Arisara ;
Guiot, Aurelie ;
Madenci, Arin ;
Walsh, Spencer ;
Ilg, Karl J. ;
Gupta, Sanjaya K. ;
Latchamsetty, Rakesh ;
Bagwe, Suveer ;
Myles, James D. ;
Crawford, Thomas ;
Good, Eric ;
Bogun, Frank ;
Pelosi, Frank ;
Morady, Fred ;
Oral, Hakan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (06) :626-631
[4]   Relationship between left atrium catheter contact force and pacing threshold [J].
Barrio-Lopez, Teresa ;
Ortiz, Mercedes ;
Castellanos, Eduardo ;
Lazaro, Carla ;
Salas, Jefferson ;
Madero, Sergio ;
Almendral, Jesus .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (02) :147-155
[5]   CMR-Guided Approach to Localize and Ablate Gaps in Repeat AF Ablation Procedure [J].
Bisbal, Felipe ;
Guiu, Esther ;
Cabanas-Grandio, Pilar ;
Berruezo, Antonio ;
Prat-Gonzalez, Susana ;
Vidal, Barbara ;
Garrido, Cesar ;
Andreu, David ;
Fernandez-Armenta, Juan ;
Maria Tolosana, Jose ;
Arbelo, Elena ;
de Caralt, Teresa M. ;
Perea, Rosario J. ;
Brugada, Josep ;
Mont, Lluis .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (07) :653-663
[6]   2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design [J].
Calkins, Hugh ;
Kuck, Karl Heinz ;
Cappato, Riccardo ;
Brugada, Josep ;
Camm, A. John ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
DiMarco, John ;
Edgerton, James ;
Ellenbogen, Kenneth ;
Ezekowitz, Michael D. ;
Haines, David E. ;
Haissaguerre, Michel ;
Hindricks, Gerhard ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jalife, Jose ;
Jais, Pierre ;
Kalman, Jonathan ;
Keane, David ;
Kim, Young-Hoon ;
Kirchhof, Paulus ;
Klein, George ;
Kottkamp, Hans ;
Kumagai, Koichiro ;
Lindsay, Bruce D. ;
Mansour, Moussa ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koonlawee ;
Nakagawa, Hiroshi ;
Natale, Andrea ;
Nattel, Stanley ;
Packer, Douglas L. ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Reddy, Vivek ;
Ruskin, Jeremy N. ;
Shemin, Richard J. ;
Tsao, Hsuan-Ming ;
Wilber, David .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 33 (02) :171-257
[7]   Treatment of Atrial Fibrillation With Antiarrhythmic Drugs or Radiofrequency Ablation Two Systematic Literature Reviews and Meta-Analyses [J].
Calkins, Hugh ;
Reynolds, Matthew R. ;
Spector, Peter ;
Sondhi, Manu ;
Xu, Yingxin ;
Martin, Amber ;
Williams, Catherine J. ;
Sledge, Isabella .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04) :349-U49
[8]   Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan ;
Ambrogi, Federico ;
Biganzoli, Elia .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) :32-38
[9]   Optimization of catheter/tissue contact during pulmonary vein isolation: the impact of atrial rhythm [J].
De Ponti, Roberto ;
Marazzi, Raffaella ;
Doni, Lorenzo A. ;
Marazzato, Jacopo ;
Baratto, Claudia ;
Salerno-Uriarte, Jorge A. .
EUROPACE, 2018, 20 (02) :288-294
[10]   Circumferential pulmonary vein isolation and linear left atrial ablation as a single-catheter technique to achieve bidirectional conduction block: The pace-and-ablate approach [J].
Eitel, Charlotte ;
Hindricks, Gerhard ;
Sommer, Philipp ;
Gaspar, Thomas ;
Kircher, Simon ;
Wetzel, Ulrike ;
Dagres, Nicos ;
Esato, Masahiro ;
Bollmann, Andreas ;
Husser, Daniela ;
Hilbert, Sebastian ;
Zaker-Shahrak, Ruzbeh ;
Arya, Arash ;
Piorkowski, Christopher .
HEART RHYTHM, 2010, 7 (02) :157-164