Whole-body diffusion-weighted MRI for staging lymphoma at 3.0T: comparative study with MR imaging at 1.5T

被引:19
|
作者
Azzedine, Benaissa [1 ]
Kahina, Moussa-Bouharati [2 ]
Dimitri, Papathanassiou [2 ]
Christophe, Portefaix [1 ]
Alain, Delmer [3 ]
Claude, Marcus [1 ]
机构
[1] CHU Reims, Hop Robert Debre, Serv Radiol, Pole Imagerie, Reims, France
[2] CHU Reims, Inst Jean Godinot, Serv Med Nucl, Reims, France
[3] CHU Reims, Hop Robert Debre, Serv Hematol, Reims, France
关键词
3.0T; 1.5T DW WB MRI; Lymphomas; Ann Arbor staging; Artifacts; MALIGNANT-LYMPHOMA; PET/CT; FEASIBILITY; HODGKIN;
D O I
10.1016/j.clinimag.2014.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare 3T and 1.5T Whole Body Diffusion Weighted MRI (WB-DW-MRI) in patients at initial diagnosis of lymphoma. Methods: Twenty-three patients were included. We performed a 3.0T and 1.5T WB-DW-MRI with 18 F-Fluoride Positron Emission Tomography Computed Tomography (PET-CT) as the reference standard. Image quality, lymph node, organ involvement, and Ann Arbor staging were evaluated. Results: Major artifacts were found in 2/23 patients at 3.0T. Concordance was excellent between 1.5T and 3T for nodal (Intraclass Correlation Coefficient (CCI)=0.995), organ involvement (CCI=0.990), and Ann Arbor stages (k=0.967). Conclusion: A 3T WB-DW-MRI yields accurate assessment and staging of lymphoma comparable to 1.5T. Published by Elsevier Inc.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 50 条
  • [1] Whole-Body MRI, Including Diffusion-Weighted Imaging, for Staging Lymphoma: Comparison With CT in a Prospective Multicenter Study
    Kwee, Thomas C.
    Vermoolen, Malou A.
    Akkerman, Erik A.
    Kersten, Marie Jose
    Fijnheer, Rob
    Ludwig, Inge
    Beek, Frederik J. A.
    van Leeuwen, Maarten S.
    Bierings, Marc B.
    Bruin, Marrie C. A.
    Zsiros, Jozsef
    van Ufford, Henriette M. E. Quarles
    de Klerk, John M. H.
    Adam, Judit
    Stoker, Jaap
    Uiterwaal, Cuno S.
    Nievelstein, Rutger A. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) : 26 - 36
  • [2] Whole-body diffusion-weighted imaging for staging malignant lymphoma in children
    Kwee, Thomas C.
    Takahara, Taro
    Vermoolen, Malou A.
    Bierings, Marc B.
    Mali, Willem P.
    Nievelstein, Rutger A. J.
    PEDIATRIC RADIOLOGY, 2010, 40 (10) : 1592 - 1602
  • [3] Whole-body diffusion-weighted imaging for staging malignant lymphoma in children
    Thomas C. Kwee
    Taro Takahara
    Malou A. Vermoolen
    Marc B. Bierings
    Willem P. Mali
    Rutger A. J. Nievelstein
    Pediatric Radiology, 2010, 40 : 1592 - 1602
  • [4] Whole-Body Diffusion-Weighted Imaging: The Added Value to Whole-Body MRI at Initial Diagnosis of Lymphoma
    Gu, Jing
    Chan, Tao
    Zhang, Jingbo
    Leung, Anskar Y. H.
    Kwong, Yok-Lam
    Khong, Pek-Lan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : W384 - W391
  • [5] Diagnostic accuracy of whole-body diffusion-weighted magnetic resonance imaging with 3.0T in detection of primary and metastatic neoplasms
    Akay, Sinan
    Kocaoglu, Murat
    Emer, Ozdes
    Battal, Bilal
    Arslan, Nuri
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 274 - 282
  • [6] Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging
    Muertz, P.
    Kaschner, M.
    Lakghomi, A.
    Gieseke, J.
    Willinek, W. A.
    Schild, H. H.
    Thomas, D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (04) : 696 - 702
  • [7] Whole-Body MRI, Including Diffusion-Weighted Imaging, for the Initial Staging of Malignant Lymphoma Comparison to Computed Tomography
    Kwee, Thomas C.
    van Ufford, Henriette M. E. Quarles
    Beek, Frederik J.
    Takahara, Taro
    Uiterwaal, Cuno S.
    Bierings, Marc B.
    Ludwig, Inge
    Fijnheer, Rob
    Nievelstein, Rutger A. J.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (10) : 683 - 690
  • [8] Whole-body MRI with diffusion-weighted imaging: a valuable alternative to contrast-enhanced CT for initial staging of aggressive lymphoma
    Balbo-Mussetto, A.
    Cirillo, S.
    Bruna, R.
    Gueli, A.
    Saviolo, C.
    Petracchini, M.
    Fornari, A.
    Lario, C. V.
    Gottardi, D.
    De Crescenzo, A.
    Tarella, C.
    CLINICAL RADIOLOGY, 2016, 71 (03) : 271 - 279
  • [9] Improved geometric accuracy of whole body diffusion-weighted imaging at 1.5T and 3T using reverse polarity gradients
    Sjoholm, T.
    Kullberg, J.
    Strand, R.
    Engstrom, M.
    Ahlstrom, H.
    Malmberg, F.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T
    Muertz, Petra
    Kaschner, Marius
    Traeber, Frank
    Kukuk, Guido M.
    Buedenbender, Sarah M.
    Skowasch, Dirk
    Gieseke, Juergen
    Schild, Hans H.
    Willinek, Winfried A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3614 - 3623