Colloidal gold supported onto glassy carbon substrates as an amperometric sensor for carbohydrates in flow injection and liquid chromatography

被引:39
作者
Casella, IG [1 ]
Destradis, A [1 ]
Desimoni, E [1 ]
机构
[1] UNIV MILAN,DIPARTIMENTO FISIOL PIANTE COLTIVATE & CHIM AGR,I-20133 MILAN,ITALY
关键词
gold-modified glassy carbon electrode; alkaline media; carbohydrate; biochemical sensor; glucose; clinical sample;
D O I
10.1039/an9962100249
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Gold microparticles dispersed on glassy carbon structures mere characterized by SEM, Some aspects of the electrooxidation mechanism of carbohydrates in alkaline medium were investigated by cyclic voltammetry. The chemically modified electrode described was tested in flow injection and anion-exchange LC with pulsed amperometric detection. The electrode response was stable: over 8 h a 1.53% signal loss was observed for all of the investigated carbohydrates. Typical relative standard deviations ranged between 0.9 and 3.5%. The detector response was linearly dependent on the concentrations of polyhydroxyl compounds and monosaccharides over three orders of magnitude, Linear plots of 1/I-p and 1/c indicated a Langmuir-type adsorption of analyte on the catalytic sites, All investigated carbohydrates were detected at the picomole level. The determination of glucose in human biological fluids was achieved by LC in an alkaline medium.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 37 条
[1]   ELEMENTARY STEPS OF ELECTROCHEMICAL OXIDATION OF SINGLE-CRYSTAL PLANES OF AU .2. A CHEMICAL AND STRUCTURAL BASIS OF OXIDATION OF THE (111) PLANE [J].
ANGERSTEINKOZLOWSKA, H ;
CONWAY, BE ;
HAMELIN, A ;
STOICOVICIU, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 228 (1-2) :429-453
[2]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[3]   ELECTROCHEMICAL OXIDATION OF FORMALDEHYDE ON GOLD AND SILVER [J].
BELTOWSKABRZEZINSKA, M .
ELECTROCHIMICA ACTA, 1985, 30 (09) :1193-1198
[4]   PULSED AMPEROMETRIC DETECTION OF GLUCOSE IN BIOLOGICAL-FLUIDS AT A SURFACE-MODIFIED GOLD ELECTRODE [J].
BINDRA, DS ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2566-2570
[5]   AN INSITU WEIGHING STUDY OF THE MECHANISM FOR THE FORMATION OF THE ADSORBED OXYGEN MONOLAYER AT A GOLD ELECTRODE [J].
BRUCKENSTEIN, S ;
SHAY, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :131-136
[6]   STUDY OF A NICKEL-CATALYZED GLASSY-CARBON ELECTRODE FOR DETECTION OF CARBOHYDRATES IN LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CASELLA, IG ;
DEIMONI, F ;
CATALDI, TRI .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :117-125
[7]   ELECTROCATALYTIC OXIDATION AND LIQUID-CHROMATOGRAPHIC DETECTION OF ALIPHATIC-ALCOHOLS AT A NICKEL-BASED GLASSY-CARBON MODIFIED ELECTRODE [J].
CASELLA, IG ;
CATALDI, TRI ;
SALVI, AM ;
DESIMONI, E .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3143-3150
[8]   SULFITE OXIDATION AT A PLATINUM GLASSY-CARBON ELECTRODE - DETERMINATION OF SULFITE BY ION-EXCLUSION CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
CASELLA, IG ;
MARCHESE, R .
ANALYTICA CHIMICA ACTA, 1995, 311 (02) :199-210
[9]   COBALT-BASED GLASSY-CARBON CHEMICALLY MODIFIED ELECTRODE FOR CONSTANT-POTENTIAL AMPEROMETRIC DETECTION OF CARBOHYDRATES IN FLOW-INJECTION ANALYSIS AND LIQUID-CHROMATOGRAPHY [J].
CATALDI, TRI ;
CASELLA, IG ;
DESIMONI, E ;
ROTUNNO, T .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :161-171
[10]   KINETICS AND MECHANISM OF OXIDATION OF AMINES AND ALCOHOLS AT OXIDE-COVERED NICKEL, SILVER, COPPER, AND COBALT ELECTRODES [J].
FLEISCHM.M ;
PLETCHER, D ;
KORINEK, K .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1972, (10) :1396-&