Determination of iron in blood serum using flow injection with luminol chemiluminescence detection

被引:12
|
作者
Waseem, A [1 ]
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; iron; blood serum;
D O I
10.1002/bio.787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 mumol/L (r(2) = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO42-, HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [21] Sensitive Determination of Hemoglobin in Human Blood and Serum by Flow Injection Coupled with Chemiluminescence Detection
    Cao Jun-tao
    Wang Hui
    Chen Yong-hong
    Liu Yan-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (01) : 241 - 245
  • [22] Simultaneous flow-injection determination of iron(II) and total iron by micelle enhanced luminol chemiluminescence
    Saitoh, K
    Hasebe, T
    Teshima, N
    Kurihara, M
    Kawashima, T
    ANALYTICA CHIMICA ACTA, 1998, 376 (02) : 247 - 254
  • [23] Flow Injection Chemiluminescence Determination of Paraquat using Luminol and Ag(III) Complex
    Liu, Fei
    Shi, Hongmei
    Xu, Xiangdong
    Kang, Weijun
    Li, Zhanhua
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (02) : 795 - 798
  • [24] A flow injection chemiluminescence method for the determination of lincomycin in serum using a diperiodato-cuprate (III)-luminol system
    Hu, Yufei
    Li, Gongke
    Zhang, Zhujun
    LUMINESCENCE, 2011, 26 (05) : 313 - 318
  • [25] Effect of model ligands on iron redox speciation in natural waters using flow injection with luminol chemiluminescence detection
    Ussher, SJ
    Yaqoob, M
    Achterberg, EP
    Nabi, A
    Worsfold, PJ
    ANALYTICAL CHEMISTRY, 2005, 77 (07) : 1971 - 1978
  • [26] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [27] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection (vol 519, pg 137, 2004)
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    ANALYTICA CHIMICA ACTA, 2005, 531 (01) : 161 - 161
  • [28] Determination of cobalt and iron in estuarine and coastal waters using flow injection with chemiluminescence detection
    Cannizzaro, V
    Bowie, AR
    Sax, A
    Achterberg, EP
    Worsfold, PJ
    ANALYST, 2000, 125 (01) : 51 - 57
  • [29] Flow Injection Chemiluminescence Determination of Retinol and -Tocopherol in Blood Serum and Pharmaceuticals
    Asgher, Mohammad
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 12 - 24
  • [30] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    Analytical Sciences, 2003, 19 : 625 - 626