Determination of iron in blood serum using flow injection with luminol chemiluminescence detection

被引:12
作者
Waseem, A [1 ]
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; iron; blood serum;
D O I
10.1002/bio.787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 mumol/L (r(2) = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO42-, HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [21] Determination of oxytetracycline by flow injection with chemiluminescence detection
    Guo, LQ
    Xie, ZH
    Bian, XT
    Lin, XC
    Zhang, WL
    Liu, XH
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 129 - 134
  • [22] Determination of methyltestosterone using flow injection with chemiluminescence detection
    Xie, ZH
    Ouyang, XQ
    Guo, LQ
    Lin, XC
    Chen, GN
    LUMINESCENCE, 2005, 20 (03) : 231 - 235
  • [23] Determination of Iproniazid by Flow Injection Analysis with Chemiluminescence Detection Based on the Oxidation of Luminol by Trichloroisocyanuric Acid and Sodium Dichloroisocyanurate
    Safavi, A.
    Absalan, G.
    Bamdad, F.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2009, 17 (01) : 17 - 21
  • [24] Sensitive determination of captopril by flow injection analysis with chemiluminescence detection based on the enhancement of the luminol reaction
    Economou, A
    Themelis, DG
    Theodoridis, G
    Tzanavaras, PD
    ANALYTICA CHIMICA ACTA, 2002, 463 (02) : 249 - 255
  • [25] Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system
    Liu, HY
    Zhang, L
    Zhou, JM
    Hao, YH
    He, PG
    Fang, YZ
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 125 - 129
  • [26] Determination of sulphite using an immobilized enzyme with flow injection chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Waseem, A
    Masoom-Yasinzai, M
    LUMINESCENCE, 2004, 19 (01) : 26 - 30
  • [27] Determination of Cr(III) in urine, blood serum and hair using flow injection chemiluminescence analysis
    R. Escobar
    M. S. García-Domínguez
    A. Guiraúm
    F. F. de la Rosa
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 509 - 511
  • [28] Flow injection determination of humic acid with chemiluminescence detection
    Tian, YH
    Song, QJ
    Hua, ZZ
    ANALYTICAL LETTERS, 2005, 38 (14) : 2439 - 2447
  • [29] Determination of dipyridamole by flow injection analysis with chemiluminescence detection
    Yang, ML
    Li, LQ
    Feng, ML
    Lü, JR
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 161 - 163
  • [30] Flow-injection determination of total iron in freshwater samples with neutralisation chemiluminescence
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (14) : 1071 - 1080