Determination of iron in blood serum using flow injection with luminol chemiluminescence detection

被引:12
作者
Waseem, A [1 ]
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow injection analysis; chemiluminescence; iron; blood serum;
D O I
10.1002/bio.787
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid flow injection method is reported for the determination of iron in blood serum after acid digestion with HNO3 and HClO4, based on luminol CL detection in the absence of added oxidant. The detection limit (3 s) was 1.0 nmol/L with a sample throughput of 120/h. The calibration graph was linear over the range 0.001-1.0 mumol/L (r(2) = 0.9974), with relative standard deviations (RSD) (n = 4) in the range 3.2-5%. The effect of interfering cations (Ca(II), Mg(II), Cu(II), Cd(II), Pb(II), Mn(II), Zn(II), Ni(II), Co(II) and Fe(III)) and anions (Cl-, SO42-, HCO3-, NO3-, NO2-) were studied using a luminol CL system for Fe(II) determination. The method was applied to normal blood serum and the results (1.32 +/- 0.08-1.74 +/- 0.05 mg/L) were compared with those from a spectrophotometric reference method (1.34 +/- 0.06-1.80 +/- 0.10 mg/L), which agree fairly well with the overall reference range in blood. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [1] Determination of silicate in freshwaters using flow injection with luminol chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 137 - 142
  • [2] Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    ACTA CHIMICA SLOVENICA, 2011, 58 (03) : 569 - 575
  • [3] Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2006, 21 (03) : 174 - 178
  • [4] Determination of carbaryl by flow injection with luminol chemiluminescence inhibition detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    Siddiqui, Masood Ahmed
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (12) : 825 - 832
  • [5] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [6] Determination of arsenic(V) in freshwaters by flow injection with luminol chemiluminescence detection
    Attiq-Ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (09) : 603 - 612
  • [7] Investigation of iron(III) reduction and trace metal interferences in the determination of dissolved iron in seawater using flow injection with luminol chemiluminescence detection
    Ussher, Simon J.
    Milne, Angela
    Landing, William M.
    Attiq-ur-Rehman, Kakar
    Seguret, Marie J. M.
    Holland, Toby
    Achterberg, Eric P.
    Nabi, Abdul
    Worsfold, Paul J.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 259 - 265
  • [8] Flow injection chemiluminescence determination of isoniazid using luminol and silver nanoparticles
    Haghighi, Behzad
    Bozorgzadeh, Somayyeh
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 192 - 197
  • [9] Determination of nanomolar concentrations of phosphate in freshwaters using flow injection with luminol chemiluminescence detection
    Yaqoob, M
    Nabi, A
    Worsfold, PJ
    ANALYTICA CHIMICA ACTA, 2004, 510 (02) : 213 - 218
  • [10] Determination of subnanomolar concentrations of vanadium in environmental water samples using flow injection with luminol chemiluminescence detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    LUMINESCENCE, 2011, 26 (06) : 403 - 409