An Integrated Amperometric Biosensor for the Determination of Lactose in Milk and Dairy Products

被引:62
|
作者
Conzuelo, F. [1 ]
Gamella, M. [1 ]
Campuzano, S. [1 ]
Ruiz, M. A. [1 ]
Reviejo, A. J. [1 ]
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
Self-assembled monolayers; enzyme electrodes; lactose; milk; BETA-GALACTOSIDASE; GLUCOSE-OXIDASE; FLOW-ANALYSIS; TETRATHIAFULVALENE; ELECTRODES; LACTULOSE;
D O I
10.1021/jf101173e
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
An integrated amperometric biosensor for the determination of lactose is reported. The bioelectrode design is based on the use of a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)modified gold electrode on which the enzymes beta-galactosidase (beta-Gal), glucose oxidase (GOD), peroxidase (HAP) and the mediator tetrathiafulvalene (TTF) are coimmobilized by a dialysis membrane. beta-Gal catalyzes the hydrolysis of lactose, and the produced glucose is catalytically oxidized to gluconic acid and H2O2, which is reduced in the presence of HAP. This enzyme reaction is mediated by TTF, and the reduction of TTF+ at 0.00 V (vs Ag/AgCl) gives rise to an amperometric signal proportional to the lactose concentration. The biosensor exhibits a good repeatability of the measurement carried out with the same biosensor, a good reproducibility of the responses obtained with different biosensors and a useful lifetime of 28 days. A linear calibration plot was obtained for lactose over the 1.5 x 10(-6) to 1.2 x 10(-4) M concentration range, with a limit of detection of 4.6 x 10(-7) M. The effect of potential interferents (sucrose, lactulose, fructose, arabinose, maltose, galactose, glucose and uric and ascorbic acids) on the biosensor response was evaluated. Furthermore, the bioelectrode exhibits a suitable performance in flow-injection systems in connection with amperometric detection. The developed biosensor was applied to the determination of lactose in milk and other foodstuffs (chocolate, butter, margarine, yogurt, cheese and mayonnaise), and the results obtained were validated by comparison with those provided by using a commercial enzyme test kit.
引用
收藏
页码:7141 / 7148
页数:8
相关论文
共 50 条
  • [31] MYCOTOXINS IN MILK AND IN DAIRY PRODUCTS
    Ushkalov, V
    Danchuk, V
    Midyk, S.
    Voloshchuk, N.
    Danchuk, O.
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-UKRAINE, 2020, 14 (03): : 137 - 149
  • [32] Detection of glucose, galactose, and lactose in milk with a microdialysis-coupled flow injection amperometric sensor
    Rajendran, V
    Irudayaraj, J
    JOURNAL OF DAIRY SCIENCE, 2002, 85 (06) : 1357 - 1361
  • [33] Development of a new two-enzyme biosensor based on poly(pyrrole-co-3,4-ethylenedioxythiophene) for lactose determination in milk
    Gursoy, Oguz
    Sen Gursoy, Songul
    Cogal, Sadik
    Cogal, Gamze Celik
    POLYMER ENGINEERING AND SCIENCE, 2018, 58 (06) : 839 - 848
  • [34] Advances in Low-Lactose/Lactose-Free Dairy Products and Their Production
    Li, Aili
    Zheng, Jie
    Han, Xueting
    Yang, Sijia
    Cheng, Shihui
    Zhao, Jingwen
    Zhou, Wenjia
    Lu, Yan
    FOODS, 2023, 12 (13)
  • [35] Development of three-enzyme lactose amperometric biosensor modified by nanosized poly (meta-phenylenediamine) film
    Pyeshkova, V. M.
    Dudchenko, O. Y.
    Soldatkin, O. O.
    Alekseev, S. A.
    Seker, T.
    Kurc, B. Akata
    Dzyadevych, S. V.
    APPLIED NANOSCIENCE, 2022, 12 (04) : 1267 - 1274
  • [36] Novel products and new technologies for use of a familiar carbohydrate, milk lactose
    Yang, ST
    Silva, EM
    JOURNAL OF DAIRY SCIENCE, 1995, 78 (11) : 2541 - 2562
  • [37] Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination
    Simelevicius, Dainius
    Baronas, Romas
    Kulys, Juozas
    SENSORS, 2012, 12 (04): : 4897 - 4917
  • [38] A nylon membrane based amperometric biosensor for polyphenol determination
    Narang, Jagriti
    Chauhan, Nidhi
    Singh, Anamika
    Pundir, C. S.
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2011, 72 (3-4) : 276 - 281
  • [39] Amperometric biosensor coupled to capillary electrophoresis for glucose determination
    Chen, G
    Wang, YT
    Yang, PY
    MICROCHIMICA ACTA, 2005, 150 (3-4) : 239 - 245
  • [40] Determination of Penicillins in Milk by a Dual-Optrode Biosensor
    Kagan, Margarita
    Printsmann, Gunnar
    Kivirand, Kairi
    Rinken, Toonika
    ANALYTICAL LETTERS, 2017, 50 (05) : 819 - 828