A shipboard method for catalytic kinetic spectrophotometric determination of trace Cu(II) concentrations in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell

被引:8
作者
Wang, Ting [1 ,2 ]
Huang, Yongming [1 ]
Zhu, Yong [3 ]
Xu, Jin [1 ]
Li, Dewang [3 ]
Wang, Bin [3 ]
Guo, Weidong [1 ,2 ]
Yuan, Dongxing [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen, Peoples R China
[2] Xiamen Univ, Coll Ocean & Earth Sci, Xiamen, Peoples R China
[3] Minist Nat Resources, Key Lab Marine Ecosyst Dynam, Inst Oceanog 2, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Cu(II); Catalytic kinetic method; Spectrophotometry; Reverse flow injection analysis; Liquid waveguide capillary cell; Estuarine and coastal waters; SEA-WATER; COPPER; CU; PRECONCENTRATION; EXTRACTION; TOXICITY; ENVIRONMENT; ESTUARINE; AMMONIUM; ATLANTIC;
D O I
10.1016/j.microc.2022.107441
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By using reverse flow injection analysis (rFIA) and a 1.0 m liquid waveguide capillary cell (LWCC), an automatic and sensitive catalytic kinetic spectrophotometric method for on-line monitoring of Cu(II) concentrations in estuarine and coastal waters was established. Cu(II) detection was based on its catalytic effect on glutathione (GSH) oxidation by potassium ferricyanide under acidic conditions. The change in absorbance of potassium ferricyanide at 420 nm was used to monitor the reaction spectrophotometrically. Experimental parameters were optimized using a univariate experimental design approach and it was ensured that the method was free of interference from co-occurring ions such as Fe(II), Fe(III), Mn, Zn, Cd, Al, Cr, Ni and Co. The proposed method was shown to have high sensitivity with a detection limit of 0.15 nmol L-1 in a pure water matrix and 0.23 nmol L-1 in a seawater matrix. Linearity was achieved within the range of 0.45-15 nmol L-1 in a pure water matrix and 0.69-10 nmol L(-1 )in a seawater matrix using a 200 cm reaction coil, while the upper limits can be extended to 40 and 25 nmol L-1, respectively, by using a shorter (100 cm) reaction coil. A high level of Cu(II) recovery was maintained, ranging between 95.2% and 101%. The relative standard deviations (RSDs) of blanks and samples spiked with 5 nmol L-1 Cu(II) standard were 1.52% (n = 13) and 1.10% (n = 13), respectively. The method was confirmed to be free of carry-over effect and a sample throughput of 26 h-1 was achieved. The method was successfully applied to underway and on-board determination of Cu(II) concentrations from a surface transect in the Jiulong Estuary and a vertical profile in the Yangtze Estuary, China, respectively.
引用
收藏
页数:7
相关论文
共 49 条
[1]   Determination of iron in seawater [J].
Achterberg, EP ;
Holland, TW ;
Bowie, AR ;
Fauzi, R ;
Mantoura, C ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 2001, 442 (01) :1-14
[2]   EFFECTS OF INORGANIC COMPLEXING ON TOXICITY OF COPPER TO DAPHNIA-MAGNA [J].
ANDREW, RW ;
BIESINGER, KE ;
GLASS, GE .
WATER RESEARCH, 1977, 11 (03) :309-315
[3]   The effects of Cu and Fe availability on the growth and Cu : C ratios of marine diatoms [J].
Annett, Amber L. ;
Lapi, Suzanne ;
Ruth, Thomas J. ;
Maldonado, Maria T. .
LIMNOLOGY AND OCEANOGRAPHY, 2008, 53 (06) :2451-2461
[4]   THE CHEMICAL MASS BALANCE OF THE AMAZON PLUME .2. COPPER, NICKEL, AND CADMIUM [J].
BOYLE, EA ;
HUESTED, SS ;
GRANT, B .
DEEP-SEA RESEARCH PART A-OCEANOGRAPHIC RESEARCH PAPERS, 1982, 29 (11) :1355-1364
[5]   In-situ measurements of Cu in an estuarine environment using a portable spectrophotometric analysis system [J].
Callahan, MR ;
Kaltenbacher, EA ;
Byrne, RH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (02) :587-593
[6]   In-field determination of nanomolar nitrite in seawater using a sequential injection technique combined with solid phase enrichment and colorimetric detection [J].
Chen, Guohe ;
Yuan, Dongxing ;
Huang, Yongming ;
Zhang, Min ;
Bergman, Maria .
ANALYTICA CHIMICA ACTA, 2008, 620 (1-2) :82-88
[7]   DETERMINATION OF COPPER IN SEA-WATER USING A FLOW-INJECTION METHOD WITH CHEMILUMINESCENCE DETECTION [J].
COALE, KH ;
JOHNSON, KS ;
STOUT, PM ;
SAKAMOTO, CM .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :345-351
[8]   Land inputs, behaviour and contamination levels of copper in a Ria Estuary (NW Spain) [J].
Cobelo-García, A ;
Prego, R .
MARINE ENVIRONMENTAL RESEARCH, 2003, 56 (03) :403-422
[9]   A critical examination of the components of the Schlieren effect in flow analysis [J].
Dias, ACB ;
Borges, EP ;
Zagatto, EAG ;
Worsfold, PJ .
TALANTA, 2006, 68 (04) :1076-1082
[10]   Microplate-reader method for the rapid analysis of copper in natural waters with chemiluminescence detection [J].
Durand, Axel ;
Chase, Zanna ;
Remenyi, Tomas ;
Queroue, Fabien .
FRONTIERS IN MICROBIOLOGY, 2013, 3