Comparison of visual results and optical quality of two presbyopia-correcting intraocular lenses: TECNIS symfony versus TECNIS synergy

被引:18
作者
Shin, Da Eun [1 ]
Lee, Hun [2 ]
Kim, Tae-Im [3 ]
Koh, Kyungmin [1 ]
机构
[1] Konyang Univ, Kims Eye Hosp, Dept Opthalmol, Coll Med, 136 Youngshinro, Seoul 07301, South Korea
[2] Univ Ulsan, Asan Med Ctr, Dept Ophthalmol, Coll Med, Seoul, South Korea
[3] Yonsei Univ, Severance Eye Hosp, Dept Opthalmol, Coll Med, Seoul, South Korea
关键词
Defocus curve; extended depth of focus; extended range of vision; presbyopia; presbyopia-correcting intraocular lens; DEPTH-OF-FOCUS; EXTENDED DEPTH; PATIENT SATISFACTION; CLINICAL-OUTCOMES; IMPLANTATION; RANGE; PERFORMANCE; IOL;
D O I
10.1177/11206721221093024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis (R) Symfony (R), Johnson & Johnson Vision, Santa Ana, CA, USA) and a new presbyopia-correcting IOL that combines EDOF and multifocal profiles (ZFR00; Tecnis (R) Synergy (R), Johnson & Johnson Vision, Santa Ana, CA, USA) with the same material. Methods: The medical records of patients undergoing cataract surgery with ZXR00 or ZFR00 implantation between March 2021 and July 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA), corrected distance VA, defocus curves, refractive errors (RE), optical quality parameters, and patient-reported visual performance parameters were the main outcome measures. Results: Among the twenty-three enrolled patients, twelve patients (21 eyes) received ZXR00 and nine patients (17 eyes) received ZFR00. The mean age of the patients was 59.6 +/- 10.6 (range: 49 to 70) and 65.2 +/- 8.2 (range: 45 to 82) years in ZXR00 and ZFR00 groups, respectively, without significant difference. There was not a significant difference between the two groups in terms of baseline parameters and postoperative RE. The ZFR00 group showed markedly superior intermediate and near VA (p < 0.001 for all) at 3 months postoperatively. In terms of optical quality, ZXR00 was significantly better than ZFR00 (p < 0.001). Conclusions: Both IOLs had comparable distance VA. ZFR00 IOL was superior for intermediate and near visual acuity, but ZXR00 IOL was better for optical quality. Research with more participants is needed to support this finding.
引用
收藏
页码:3461 / 3469
页数:9
相关论文
共 38 条
  • [1] Preclinical metrics to predict through-focus visual acuity for pseudophakic patients
    Alarcon, Aixa
    Canovas, Carmen
    Rosen, Robert
    Weeber, Henk
    Tsai, Linda
    Hileman, Kendra
    Piers, Patricia
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05): : 1877 - 1888
  • [2] Breyer DRH, 2017, ASIA-PAC J OPHTHALMO, V6, P339, DOI 10.22608/APO.2017186
  • [3] Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study
    Chen, Tianyu
    Yu, Fang
    Lin, Huayou
    Zhao, Yinying
    Chang, Pingjun
    Lin, Lei
    Chen, Qi
    Zheng, Qian
    Zhao, Yun-e
    Lu, Fan
    Li, Jin
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (11) : 1530 - 1535
  • [4] Chung Jin Kwon, 2019, Korean J Ophthalmol, V33, P451, DOI 10.3341/kjo.2019.0064
  • [5] Dissatisfaction after implantation of multifocal intraocular lenses
    de Vries, Niels E.
    Webers, Carroll A. B.
    Touwslager, Wouter R. H.
    Bauer, Noel J. C.
    de Brabander, John
    Berendschot, Tos T.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 859 - 865
  • [6] Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses
    Ferreira, Tiago B.
    Ribeiro, Filomena J.
    Silva, Diana
    Matos, Ana Claudia
    Gaspar, Sylvia
    Almeida, Soraia
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (03) : 280 - 287
  • [7] Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens
    Gabric, Nikica
    Gabric, Ivan
    Gabric, Kresimir
    Biscevic, Alma
    Pinero, David P.
    Bohac, Maja
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (04) : 256 - +
  • [8] Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients
    Garcin, Thibaud
    Grivet, Damien
    Thuret, Gilles
    Gain, Philippe
    [J]. PLOS ONE, 2020, 15 (10):
  • [9] Ha Ahnul, 2018, Korean J Ophthalmol, V32, P241, DOI 10.3341/kjo.2017.0063
  • [10] Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system
    Hu, Ai-Lian
    Qiao, Li-Ya
    Zhang, Ye
    Cai, Xiao-Gu
    Li, Lei
    Wan, Xiu Hua
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (05) : 1043 - 1050