Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging

被引:6
作者
Wang, Yuanguo [1 ]
Wang, Yadan [1 ]
Liu, Mingzhou [1 ]
Lan, Zhengfeng [2 ]
Zheng, Chichao [2 ]
Peng, Hu [2 ,3 ]
机构
[1] Hefei Univ Technol, Sch Mech Engn, Hefei 230009, Peoples R China
[2] Hefei Univ Technol, Dept Biomed Engn, Hefei 230009, Peoples R China
[3] Hefei Univ Technol, Anhui Prov Key Lab Measuring Theory & Precis Inst, Hefei 230009, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Minimum variance beamforming; Adaptive beamformer; Covariance matrix; Coherence; Standard deviation; LAG SPATIAL COHERENCE; ALGORITHM; GPU;
D O I
10.1186/s12938-022-01007-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The minimum variance (MV) beamformer can significantly improve the image resolution in ultrasound imaging, but it has limited performance in noise reduction. We recently proposed the covariance matrix-based statistical beamforming (CMSB) for medical ultrasound imaging to reduce sidelobes and incoherent clutter. Methods: In this paper, we aim to improve the imaging performance of the MV beamformer by introducing a new pixel-based adaptive weighting approach based on CMSB, which is named as covariance matrix-based adaptive weighting (CMSAW). The proposed CMSAW estimates the mean-to-standard-deviation ratio (MSR) of a modified covariance matrix reconstructed by adaptive spatial smoothing, rotary averaging, and diagonal reducing. Moreover, adaptive diagonal reducing based on the aperture coherence is introduced in CMSAW to enhance the performance in speckle preservation. Results: The proposed CMSAW-weighted MV (CMSAW-MV) was validated through simulation, phantom experiments, and in vivo studies. The phantom experimental results show that CMSAW-MV obtains resolution improvement of 21.3% and simultaneously achieves average improvements of 96.4% and 71.8% in average contrast and generalized contrast-to-noise ratio (gCNR) for anechoic cyst, respectively, compared with MV. in vivo studies indicate that CMSAW-MV improves the noise reduction performance of MV beamformer. Conclusion: Simulation, experimental, and in vivo results all show that CMSAW-MV can improve resolution and suppress sidelobes and incoherent clutter and noise. These results demonstrate the effectiveness of CMSAW in improving the imaging performance of MV beamformer. Moreover, the proposed CMSAW with a computational complexity of O(N-2) has the potential to be implemented in real time using the graphics processing unit.
引用
收藏
页数:24
相关论文
共 42 条
[1]   Implementing Capon Beamforming on a GPU for Real-Time Cardiac Ultrasound Imaging [J].
Asen, Jon Petter ;
Buskenes, Jo Inge ;
Nilsen, Carl-Inge Colombo ;
Austeng, Andreas ;
Holm, Sverre .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (01) :76-85
[2]   Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (04) :858-867
[3]   Eigenspace-Based Minimum Variance Beamforming Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2381-2390
[4]   Minimum Variance Beamforming Combined with Adaptive Coherence Weighting Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (09) :1923-1931
[5]   Resolution and Brightness Characteristics of Short-Lag Spatial Coherence (SLSC) Images [J].
Bell, Muyinatu A. Lediju ;
Dahl, Jeremy J. ;
Trahey, Gregg E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (07) :1265-1276
[6]   SHORT-LAG SPATIAL COHERENCE IMAGING OF CARDIAC ULTRASOUND DATA: INITIAL CLINICAL RESULTS [J].
Bell, Muyinatu A. Lediju ;
Goswami, Robi ;
Kisslo, Joseph A. ;
Dahl, Jeremy J. ;
Trahey, Gregg E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (10) :1861-1874
[7]   Recovery of the Complete Data Set From Focused Transmit Beams [J].
Bottenus, Nick .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (01) :30-38
[8]   Synthetic Aperture Focusing for Short-Lag Spatial Coherence Imaging [J].
Bottenus, Nick ;
Byram, Brett C. ;
Dahl, Jeremy J. ;
Trahey, Gregg E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) :1816-1826
[9]   HIGH RESOLUTION MINIMUM VARIANCE BEAMFORMER WITH LOW COMPLEXITY IN MEDICAL ULTRASOUND IMAGING [J].
Deylami, Ali Mohades ;
Asl, Babak Mohammadzadeh .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (10) :2805-2818
[10]   ITERATIVE MINIMUM VARIANCE BEAMFORMER WITH LOW COMPLEXITY FOR MEDICAL ULTRASOUND IMAGING [J].
Deylami, Ali Mohades ;
Asl, Babak Mohammadzadeh .