Comparing the inter-observer reliability of the Tada formula among neurosurgeons while estimating the intracerebral haematoma volume

被引:2
|
作者
Gong, Kai [1 ]
Shi, Tao [1 ]
Zhao, Lizheng [2 ]
Xu, Zhong [3 ]
Wang, Zhanxiang [4 ]
机构
[1] Xiamen Univ, Dept Neurosurg, Affiliated Hosp 1, Xiamen, Fujian, Peoples R China
[2] Xiamen Humanity Rehabil Hosp, Dept Rehabil, Xiamen, Fujian, Peoples R China
[3] Xiamen Univ, Dept Gastroenterol, Affiliated Hosp 1, Xiamen, Fujian, Peoples R China
[4] Xiamen Univ, Affiliated Hosp 1, 55 Zhenhai Rd, Xiamen 361003, Fujian, Peoples R China
关键词
Intracerebral haemorrhage; Computed tomography; Tada formula; Inter-observer reliability; HEMORRHAGE VOLUME; CONSERVATIVE TREATMENT; SCORE; ACCURACY; WARFARIN; SURGERY; SYSTEM; MISTIE; SHAPE;
D O I
10.1016/j.clineuro.2021.106668
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare the inter-observer reliability among neurosurgeons while estimating the intracerebral haematoma (ICH) volume by the Tada formula and assess its influence on predicting the severity and prognosis of various ICHs. Methods: We obtained clinical data from 262 consecutive patients with spontaneous ICH. The haematoma volume was independently calculated and compared by 3D Slicer and eight neurosurgeons. The inter-observer reliability was obtained by calculating the intraclass correlation coefficients (ICC) and Cohen's kappa score (kappa), within different shape and volume ICH subgroups. We conducted the receiver operating characteristic analysis to assess the predictive value of the ICH volume evaluated for clinical features, including the Glasgow Coma Scale at the onset of the disease, ICH-related surgical treatments, the length of stay in the intensive care unit, the length of hospitalisation, the modified Rankin Scale score at discharge, and in-hospital deaths. Results: The median haematoma volume was 17.4 ml (range, 7.3-34.7 ml). The estimated volumes were significantly different among neurosurgeons (p < 0.001). Six out of eight neurosurgeons demonstrated obvious deviations from the 3D Slicer software (p 0.001). Round (ICC: 0.947) and tapered (ICC: 0.954) haematomas were more consistently evaluated between the neurosurgeons. We observed a substantial strength of agreement between neurosurgeons with kappa 0.693 and ICC: 0.938 in the entire volume range, and slight to fair strength of agreement with kappa > 0.175 and ICC: 0.689 between 20 ml and 40 ml volume interval. All estimated volumes had a positive predictive value for clinical features, with the area under the curve > 0.5 (p < 0.05). However, the 3D Slicer software performed relatively better than most neurosurgeons. Conclusions: There exists a significant inter-observer variability among neurosurgeons when utilizing the Tada formula, thus demonstrating significant implications for ICH-related clinical practices and researches.
引用
收藏
页数:7
相关论文
共 5 条
  • [1] Improvements of the Tada formula in estimating the intracerebral hemorrhage volume based on computed tomography
    Sha, Zhuang
    Zhang, Xinjie
    Li, Zhanying
    Feng, Jiancheng
    Quan, Wei
    Dong, Shiying
    Liu, Mingqi
    Jiang, Weiwei
    Yuan, Jiangyuan
    Huang, Jinhao
    Gao, Chuang
    Tian, Ye
    An, Shuo
    Li, Chunming
    Wang, Yuanquan
    Jiang, Rongcai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4268 - +
  • [2] Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability
    Lundqvist, Eva
    Segelsjo, Monica
    Andersson, Anna
    Magnusson, Anders
    Biglarnia, Ali-Reza
    ACTA RADIOLOGICA, 2012, 53 (09) : 966 - 972
  • [3] Diagnostic accuracy and inter-observer reliability of the O-RADS scoring system among staff radiologists in a North American academic clinical setting
    Yeli Pi
    Mitchell P. Wilson
    Prayash Katlariwala
    Medica Sam
    Thomas Ackerman
    Lee Paskar
    Vimal Patel
    Gavin Low
    Abdominal Radiology, 2021, 46 : 4967 - 4973
  • [4] Diagnostic accuracy and inter-observer reliability of the O-RADS scoring system among staff radiologists in a North American academic clinical setting
    Pi, Yeli
    Wilson, Mitchell P.
    Katlariwala, Prayash
    Sam, Medica
    Ackerman, Thomas
    Paskar, Lee
    Patel, Vimal
    Low, Gavin
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 4967 - 4973
  • [5] Pre- and postoperative radiotherapy for extremity soft tissue sarcoma: Evaluation of inter-observer target volume contouring variability among French sarcoma group radiation oncologists
    Sargos, P.
    Charleux, T.
    Haas, R. L.
    Michot, A.
    Llacer, C.
    Moureau-Zabotto, L.
    Vogin, G.
    Le Pechoux, C.
    Verry, C.
    Ducassou, A.
    Delannes, M.
    Mervoyer, A.
    Wiazzane, N.
    Thariat, J.
    Sunyach, M. P.
    Benchalal, M.
    Laredo, J. D.
    Kind, M.
    Gillon, P.
    Kantor, G.
    CANCER RADIOTHERAPIE, 2018, 22 (02): : 131 - 139