Characterization of human metal ESD reference discharge event and correlation of generator parameters to failure levels - Part I: Reference event

被引:45
作者
Chundru, R [1 ]
Pommerenke, D
Wang, K
Van Doren, T
Centola, FP
Huang, JS
机构
[1] Univ Missouri, Electromagnet Compatibil Lab, Rolla, MO 65409 USA
[2] Beijing Electrostat Discharge ESD, Inst Res, Beijing 100026, Peoples R China
关键词
discharge current; electrostatic discharge (ESD); field sensor; susceptibility; transient fields;
D O I
10.1109/TEMC.2004.837700
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrostatic discharge (ESD) generators are used for testing the robustness of electronics toward ESD. Most generators are built in accordance with the IEC 61000-4-2 specifications. Using only a few parameters, this standard specifies the peak current, the rise time and the falling edge. Lacking a transient field specification, test results vary depending on which generator is used, even if the currents are quite similar. Such a specification is needed to improve the test repeatability. As for the current, the specification should be based on a reference human metal ESD event. While keeping the presently set peak current and rise time values, such a reference ESD (5 kV, 850-mum arc length) is identified and specifications for current derivative, fields, and induced voltages are derived. The reference event parameters are compared to typical ESD generators.
引用
收藏
页码:498 / 504
页数:7
相关论文
共 23 条
[21]  
SROKA J, 2001, P 14 INT ZUR S EL CO, P189
[22]  
TRAA WG, 2001, P INT S EL COMP ZUR
[23]   Numerical modeling of electrostatic discharge generators [J].
Wang, K ;
Pommerenke, D ;
Chundru, R ;
Van Doren, T ;
Drewniak, JL ;
Shashindranath, A .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2003, 45 (02) :258-271