Magnetic particle detection by frequency mixing for immunoassay applications

被引:149
作者
Krause, Hans-Joachim
Wolters, Norbert
Zhang, Yi
Offenhaeusser, Andreas
Miethe, Peter
Meyer, Martin H. F.
Hartmann, Markus
Keusgen, Michael
机构
[1] Forschungszentrum Julich, Inst Bio & Nano Syst, IBN Bioelect 2, D-52425 Julich, Germany
[2] Forschungszentrum Julich, CNI Ctr Nanoelect Syst Informat Technol, D-52425 Julich, Germany
[3] Senova Gessell Biowissensch & Tech MbH, D-07745 Jena, Germany
[4] Univ Marburg, Inst Pharmaceut Chem, D-35032 Marburg, Germany
关键词
magnetic detection; frequency mixing; superparamagnetism; nonlinearity; induction coil; immunoassay;
D O I
10.1016/j.jmmm.2006.10.1164
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For magnetic immunoassay applications, a novel magnetic reader for quantification of magnetic particle concentrations has been developed. Upon magnetic excitation at two distinct frequencies incident on the sample, the response signal generated at a sum frequency is detected. The low-frequency field component periodically drives the magnetic particles into saturation, which is probed by the high-frequency field. The appearance of frequency mixing lines is highly specific to the nonlinearity of the superparamagnetic particles' magnetization. The optimization of field coils, differential pickup coil, preamplifier, demodulators and filters are discussed. The output signal is linear for four orders of magnitude in iron concentration. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:436 / 444
页数:9
相关论文
共 25 条
[1]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[2]   LINEAR AND NONLINEAR SUSCEPTIBILITIES OF FERROMAGNETIC FINE PARTICLES IN CU97CO3 ALLOY [J].
BITOH, T ;
OHBA, K ;
TAKAMATSU, M ;
SHIRANE, T ;
CHIKAZAWA, S .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1995, 64 (04) :1311-1319
[3]  
DEHMEL G, 1989, SENSORS, V5
[4]   Planar Hall effect sensor for magnetic micro- and nanobead detection [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2004, 84 (23) :4729-4731
[5]   Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) [J].
Ferreira, HA ;
Graham, DL ;
Freitas, PP ;
Cabral, JMS .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) :7281-7286
[6]   Tomographic imaging using the nonlinear response of magnetic particles [J].
Gleich, B ;
Weizenecker, R .
NATURE, 2005, 435 (7046) :1214-1217
[7]  
Hafeli U., 1997, Scientific and Clinical Applications of Magnetic Carriers, DOI DOI 10.1007/s10439-009-9660-y
[8]   Nonlinear dynamic susceptibilities of interacting and noninteracting magnetic nanoparticles [J].
Jönsson, P ;
Jonsson, T ;
García-Palacios, JL ;
Svedlindh, P .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2000, 222 (1-2) :219-226
[9]   Investigation of Brownian and Neel relaxation in magnetic fluids [J].
Kötitz, R ;
Weitschies, W ;
Trahms, L ;
Semmler, W .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 201 :102-104
[10]   TIME-DOMAIN STUDY OF BROWNIAN AND NEEL RELAXATION IN FERROFLUIDS [J].
KOTITZ, R ;
FANNIN, PC ;
TRAHMS, L .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1995, 149 (1-2) :42-46