Clasp fabrication using one-process molding by repeated laser sintering and high-speed milling

被引:37
作者
Nakata, Toyoki [1 ]
Shimpo, Hidemasa [1 ]
Ohkubo, Chikahiro [1 ]
机构
[1] Tsurumi Univ, Sch Dent Med, Dept Removable Prosthodont, Yokohama, Kanagawa, Japan
关键词
CAD/CAM; Clasp; Retentive force; Additive manufacturing; Hybrid process; COMPUTER-AIDED-DESIGN; CO-CR; COBALT-CHROMIUM; MECHANICAL-PROPERTIES; RETENTIVE FORCE; DEFLECTION FATIGUE; CAST CLASPS; TITANIUM; DENTISTRY; STRENGTH;
D O I
10.1016/j.jpor.2016.10.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A single machine platform that integrates repeated laser sintering and high-speed milling for one-process molding has been developed. Methods: The Akers clasp was designed using the CAD system (DWOS Partial Frameworks, Dental Wings) and fabricated using repeated laser sintering and a high-speed milling machine (LUMEX Advance-25, Matsuura) with 50-mm Co-Cr particles (CAM clasp). As controls, cast clasps of the same forms were also prepared using conventional casting methods with a Co-Cr alloy and CP titanium Grade 3. After the surface roughness was measured, the gap distance between the clasps and the tooth die was assessed using the silicone film method. The initial retentive force and changes in retention up to 10,000 cycles were also measured. The data were analyzed using two-way ANOVA and Tukey's multiple comparison test (alpha=0.05). Results: CAM clasps exhibited significantly smoother surfaces than those of cast Co-Cr and CP Ti clasps (p<0.05). However, the gap distances of the CAM clasps were significantly greater than those of the cast clasps (p<0.05). The retentive forces of both CAM and cast Co-Cr clasps were significantly higher than those of CP Ti clasps. (p<0.05). The retention of CAM clasps demonstrated a constant or slight decrease from 1000 up to 10,000 cycles. Conclusions: The CAM clasp made by repeated laser sintering and high-speed milling can be used effectively as an RPD component. (C) 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:276 / 282
页数:7
相关论文
共 34 条
[11]   CAD-CAM IN DENTISTRY [J].
DURET, F ;
BLOUIN, JL ;
DURET, B .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1988, 117 (06) :715-720
[12]   The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks [J].
Eggbeer, D ;
Bibb, R ;
Williams, R .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H3) :195-202
[13]   The Accuracy of Fit of Crowns Made From Wax Patterns Produced Conventionally (Hand Formed) and Via CAD/CAM Technology [J].
Fathi, Hawa M. ;
Al-Masoody, Azal H. ;
El-Ghezawi, Narjes ;
Johnson, Anthony .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2016, 24 (01) :P10-P17
[14]   Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology [J].
Huang, Zhuoli ;
Zhang, Lu ;
Zhu, Jingwei ;
Zhang, Xiuyin .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) :623-627
[15]   Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting [J].
Kajima, Yuka ;
Takaichi, Atsushi ;
Nakamoto, Takayuki ;
Kimura, Takahiro ;
Yogo, Yoshiaki ;
Ashida, Maki ;
Doi, Hisashi ;
Nomura, Naoyuki ;
Takahashi, Hidekazu ;
Hanawa, Takao ;
Wakabayashi, Noriyuki .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 59 :446-458
[16]   An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system [J].
Kim, Ki-Baek ;
Kim, Woong-Chul ;
Kim, Hae-Young ;
Kim, Ji-Hwan .
DENTAL MATERIALS, 2013, 29 (07) :E91-E96
[17]   Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems [J].
Kohorst, Philipp ;
Brinkmann, Henrike ;
Li, Jiang ;
Borchers, Lothar ;
Stiesch, Meike .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2009, 117 (03) :319-325
[18]   Deflection fatigue of Ti-6Al-7Nb, Co-Cr, and gold alloy cast clasps [J].
Mahmoud, A ;
Wakabayashi, N ;
Takahashi, H ;
Ohyama, T .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02) :183-188
[19]   From Powders to Dense Metal Parts: Characterization of a Commercial AlSiMg Alloy Processed through Direct Metal Laser Sintering [J].
Manfredi, Diego ;
Calignano, Flaviana ;
Krishnan, Manickavasagam ;
Canali, Riccardo ;
Ambrosio, Elisa Paola ;
Atzeni, Eleonora .
MATERIALS, 2013, 6 (03) :856-869
[20]   Effects of thermal treatments on microstructure and mechanical properties of a Co-Cr-Mo-W biomedical alloy produced, by laser sintering [J].
Mengucci, P. ;
Barucca, G. ;
Gatto, A. ;
Bassoli, E. ;
Denti, L. ;
Fiori, F. ;
Girardin, E. ;
Bastianoni, P. ;
Rutkowski, B. ;
Czyrska-Filemonowicz, A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 60 :106-117