Clasp fabrication using one-process molding by repeated laser sintering and high-speed milling

被引:37
作者
Nakata, Toyoki [1 ]
Shimpo, Hidemasa [1 ]
Ohkubo, Chikahiro [1 ]
机构
[1] Tsurumi Univ, Sch Dent Med, Dept Removable Prosthodont, Yokohama, Kanagawa, Japan
关键词
CAD/CAM; Clasp; Retentive force; Additive manufacturing; Hybrid process; COMPUTER-AIDED-DESIGN; CO-CR; COBALT-CHROMIUM; MECHANICAL-PROPERTIES; RETENTIVE FORCE; DEFLECTION FATIGUE; CAST CLASPS; TITANIUM; DENTISTRY; STRENGTH;
D O I
10.1016/j.jpor.2016.10.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: A single machine platform that integrates repeated laser sintering and high-speed milling for one-process molding has been developed. Methods: The Akers clasp was designed using the CAD system (DWOS Partial Frameworks, Dental Wings) and fabricated using repeated laser sintering and a high-speed milling machine (LUMEX Advance-25, Matsuura) with 50-mm Co-Cr particles (CAM clasp). As controls, cast clasps of the same forms were also prepared using conventional casting methods with a Co-Cr alloy and CP titanium Grade 3. After the surface roughness was measured, the gap distance between the clasps and the tooth die was assessed using the silicone film method. The initial retentive force and changes in retention up to 10,000 cycles were also measured. The data were analyzed using two-way ANOVA and Tukey's multiple comparison test (alpha=0.05). Results: CAM clasps exhibited significantly smoother surfaces than those of cast Co-Cr and CP Ti clasps (p<0.05). However, the gap distances of the CAM clasps were significantly greater than those of the cast clasps (p<0.05). The retentive forces of both CAM and cast Co-Cr clasps were significantly higher than those of CP Ti clasps. (p<0.05). The retention of CAM clasps demonstrated a constant or slight decrease from 1000 up to 10,000 cycles. Conclusions: The CAM clasp made by repeated laser sintering and high-speed milling can be used effectively as an RPD component. (C) 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:276 / 282
页数:7
相关论文
共 34 条
[1]  
[Anonymous], J SMART PROCESS
[2]   The place of direct metal laser sintering (DMLS) in dentistry and the importance of annealing [J].
Ayyildiz, Simel .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 :343-343
[3]   Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness [J].
Ayyildiz, Simel ;
Soylu, Elif Hilal ;
Ide, Semra ;
Kilic, Selim ;
Sipahi, Cumhur ;
Piskin, Bulent ;
Gokce, Hasan Suat .
JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (04) :471-478
[4]   Structural characterization of biomedical Co-Cr-Mo components produced by direct metal laser sintering [J].
Barucca, G. ;
Santecchia, E. ;
Majni, G. ;
Girardin, E. ;
Bassoli, E. ;
Denti, L. ;
Gatto, A. ;
Iuliano, L. ;
Moskalewicz, T. ;
Mengucci, P. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 48 :263-269
[5]  
Begum Z, 2014, INT J COMPUT DENT, V17, P297
[6]  
Besimo C, 1997, INT J PROSTHODONT, V10, P541
[7]   Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques [J].
Bibb, R. J. ;
Eggbeer, D. ;
Williams, R. J. ;
Woodward, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H7) :793-797
[8]   NONCAST TITANIUM RESTORATIONS IN FIXED PROSTHODONTICS [J].
BOENING, KW ;
WALTER, MH ;
REPPEL, PD .
JOURNAL OF ORAL REHABILITATION, 1992, 19 (03) :281-287
[9]   A systematic review of CAD/CAM fit restoration evaluations [J].
Boitelle, P. ;
Mawussi, B. ;
Tapie, L. ;
Fromentin, O. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (11) :853-874
[10]   Comparison of titanium and cobalt-chromium removable partial denture clasps [J].
Bridgeman, JT ;
Marker, VA ;
Hummel, SK ;
Benson, BW ;
Pace, LL .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (02) :187-193