Experimental investigation on punching resistance of R-UHPFRC-RC composite slabs

被引:32
作者
Bastien-Masse, Malena [1 ]
Bruehwiler, Eugen [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lausanne, Switzerland
关键词
Composite slab; Punching shear; Ultra-high performance fiber reinforced cement-based composite (UHPFRC); Strengthening; Near interface crack; Deformation capacity; FIBER-REINFORCED CONCRETE; SHEAR-STRENGTH; FAILURE;
D O I
10.1617/s11527-015-0596-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An effective method to strengthen existing reinforced concrete (RC) structures is to add a thin layer of ultra-high performance fiber reinforced cement-based composite (UHPFRC), with or without steel rebars, over the concrete slab to create a composite element. It was demonstrated by previous test series that this method increases rigidity, bending and shear strength of one-way RC members. This paper presents the results of punching tests on six composite slabs without transverse reinforcement. The parameters of the tests included the thickness of the UHPFRC layer and the amount of reinforcement in it. All slabs failed in punching mode with a drop in resistance after the maximum resistance was measured. For a layer of 50 mm of UHPFRC, the normalised resistance was at least 1.69 times greater than the normalised resistance of the RC reference slab. The layer of UHPFRC increased the rigidity of the slab and provided added shear resistance to the cracked RC section by out of plane bending. By doing so, it allowed more deformation to take place in the RC section before punching failure. This results in rotations and deflections at maximum resistance similar to what was observed for the reference RC slab.
引用
收藏
页码:1573 / 1590
页数:18
相关论文
共 26 条
  • [1] Punching slab strengthened with an additional concrete layer - Test and recalculations
    Amsler, Michael
    Thoma, Karel
    Heinzmann, Daniel
    [J]. BETON- UND STAHLBETONBAU, 2014, 109 (06) : 395 - 403
  • [2] Bastien-Masse M, 2014, PUNCHING TEST R UHPF
  • [3] Broms CE, 2000, ACI STRUCT J, V97, P94
  • [4] Rehabilitation and Strengthening of Concrete Structures Using Ultra-High Performance Fibre Reinforced Concrete
    Bruehwiler, Eugen
    Denarie, Emmanuel
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2013, 23 (04) : 450 - 457
  • [5] Chen CC, 2005, ACI STRUCT J, V102, P535
  • [6] Influence of prestressing on the punching strength of post-tensioned slabs
    Clement, Thibault
    Ramos, Antonio Pinho
    Ruiz, Miguel Fernandez
    Muttoni, Aurelio
    [J]. ENGINEERING STRUCTURES, 2014, 72 : 56 - 69
  • [7] Denarie E., 2011, International Journal for Restoration of Buildings and Monuments, Aedificatio Publishers Freiburg Germany, V12, No, P397, DOI DOI 10.1515/RBM-2011-6480
  • [8] Punching shear strength of interior slab-column connections strengthened with carbon fiber reinforced polymer sheets
    Esfahani, M. R.
    Kianoush, M. R.
    Moradi, A. R.
    [J]. ENGINEERING STRUCTURES, 2009, 31 (07) : 1535 - 1542
  • [9] Guandalini S, 2009, ACI STRUCT J, V106, P87
  • [10] Guidotti R., 2010, THESIS