Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model

被引:48
作者
Collinge, Cory
Merk, Bradley
Lautenschlager, Eugene P.
机构
[1] Harris Methodist Ft Worth Hosp, Ft Worth, TX USA
[2] Northwestern Univ, Dept Orthoped Surg, Chicago, IL 60611 USA
关键词
bone cement; tricalcium phosphate cement; screw augmentation; fracture fixation; osteoporotic fixation; screw pullout; resorbable cement; locked plating;
D O I
10.1097/BOT.0b013e318033093e
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The purpose of this study was to examine the effects of resorbable bone cement on screw and plate-screw fracture fixation in a porous osteoporotic bone model. Methods: Experiment 1: Screw pullout strength was assessed for 4 sets of 4.5-mm cortical screws inserted into a synthetic osteoporotic cancellous bone model, including screws inserted without cement augmentation (control), screws augmented with tricalciurn phosphate (TCP) bone cement (Norian SRS; Synthes USA, Paoli, PA), and screws augmented with polyrnethylmethacrylate. Experiment 2: The effects of cement augmentation on plate-screw fixation strength were examined by performing cantilever bending tests on 4 sets of 8 plate-screw constructions, including nonaugmented and TCP-augmented standard and locked screw-plate constructions in a similar bone model. Results: Experiment 1: Cement augmentation with both TCP and polymethylmethacrylate increased screw pullout strength from a porous osteoporotic cancellous bone model by about 4-fold (P < 0.05), and there was no significant difference between the 2 cements (P > 0.1). Experiment 2: Fixation strength was 1.5 times higher for locked plates compared with standard plates when neither was augmented with cement (P = 0.07). Cement augmentation with TCP improved fixation strength by 3.6 times for a standard plate-screw construction (P < 0.05) and 3.3 times for a locked plate-screw construction (P < 0.05). The most stable construction was the TCP-augmented locked plate, in which a 5-fold increase was observed compared with that of standard plates without TCP (P < 0.05). Conclusions: This study indicates augmenting screws with TCP cement during osteosynthesis improves fixation strength in an osteoporotic cancellous bone model. Clinical Relevance: In fracture situations in which osteoporotic bone makes screw and screw-plate fixation tenuous, screw augmentation with TCP cement should be considered as adjunct treatment.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 43 条
[31]   PULL-OUT STRENGTH OF SCREWS FROM POLYMETHYLMETHACRYLATE CEMENT [J].
MOTZKIN, NE ;
CHAO, EYS ;
AN, KN ;
WIKENHEISER, MA ;
LEWALLEN, DG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02) :320-323
[32]   Porous calcium polyphosphate scaffolds for bone substitute applications - in vitro characterization [J].
Pilliar, RM ;
Filiaggi, MJ ;
Wells, JD ;
Grynpas, MD ;
Kandel, RA .
BIOMATERIALS, 2001, 22 (09) :963-972
[33]   Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method [J].
Renner, SM ;
Lim, TH ;
Kim, WJ ;
Katolik, L ;
An, HS ;
Andersson, GBJ .
SPINE, 2004, 29 (11) :E212-E216
[34]  
Rohmiller Michael T, 2002, Spine J, V2, P255, DOI 10.1016/S1529-9430(02)00207-3
[35]   Augmentation of femoral neck fracture fixation with an injectable calcium-phosphate bone mineral cement [J].
Stankewich, CJ ;
Swiontkowski, MF ;
Tencer, AF ;
Yetkinler, DN ;
Poser, RD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (05) :786-793
[36]   MULTIAXIAL STRENGTH CHARACTERISTICS OF TRABECULAR BONE [J].
STONE, JL ;
BEAUPRE, GS ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1983, 16 (09) :743-+
[37]  
Struhl S, 1990, J Orthop Trauma, V4, P151, DOI 10.1097/00005131-199004020-00008
[38]   Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: A comparative analysis [J].
Tan, JS ;
Kwon, BK ;
Dvorak, MF ;
Fisher, CG ;
Oxland, TR .
SPINE, 2004, 29 (16) :1723-1730
[39]  
Taniwaki Yoshimichi, 2003, J Orthop Sci, V8, P408, DOI 10.1007/s10776-003-0639-6
[40]   Comparative fixation of tibial plateau fractures using α-BSM™, a calcium phosphate cement, versus cancellous bone graft [J].
Trenholm, A ;
Landry, S ;
McLaughlin, K ;
Deluzio, KJ ;
Leighton, J ;
Trask, K ;
Leighton, RK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) :698-702