Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model

被引:48
作者
Collinge, Cory
Merk, Bradley
Lautenschlager, Eugene P.
机构
[1] Harris Methodist Ft Worth Hosp, Ft Worth, TX USA
[2] Northwestern Univ, Dept Orthoped Surg, Chicago, IL 60611 USA
关键词
bone cement; tricalcium phosphate cement; screw augmentation; fracture fixation; osteoporotic fixation; screw pullout; resorbable cement; locked plating;
D O I
10.1097/BOT.0b013e318033093e
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The purpose of this study was to examine the effects of resorbable bone cement on screw and plate-screw fracture fixation in a porous osteoporotic bone model. Methods: Experiment 1: Screw pullout strength was assessed for 4 sets of 4.5-mm cortical screws inserted into a synthetic osteoporotic cancellous bone model, including screws inserted without cement augmentation (control), screws augmented with tricalciurn phosphate (TCP) bone cement (Norian SRS; Synthes USA, Paoli, PA), and screws augmented with polyrnethylmethacrylate. Experiment 2: The effects of cement augmentation on plate-screw fixation strength were examined by performing cantilever bending tests on 4 sets of 8 plate-screw constructions, including nonaugmented and TCP-augmented standard and locked screw-plate constructions in a similar bone model. Results: Experiment 1: Cement augmentation with both TCP and polymethylmethacrylate increased screw pullout strength from a porous osteoporotic cancellous bone model by about 4-fold (P < 0.05), and there was no significant difference between the 2 cements (P > 0.1). Experiment 2: Fixation strength was 1.5 times higher for locked plates compared with standard plates when neither was augmented with cement (P = 0.07). Cement augmentation with TCP improved fixation strength by 3.6 times for a standard plate-screw construction (P < 0.05) and 3.3 times for a locked plate-screw construction (P < 0.05). The most stable construction was the TCP-augmented locked plate, in which a 5-fold increase was observed compared with that of standard plates without TCP (P < 0.05). Conclusions: This study indicates augmenting screws with TCP cement during osteosynthesis improves fixation strength in an osteoporotic cancellous bone model. Clinical Relevance: In fracture situations in which osteoporotic bone makes screw and screw-plate fixation tenuous, screw augmentation with TCP cement should be considered as adjunct treatment.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 43 条
[21]  
Jazrawi LM, 2000, CLIN ORTHOP RELAT R, P235
[22]  
JOHNSON AE, IN PRESS J MAT SCI M
[23]  
KLEEMAN BC, 1992, CLIN ORTHOP RELAT R, P260
[24]   Norian SRS versus external fixation in redisplaced distal radial fractures - A randomized study in 40 patients [J].
Kopylov, P ;
Runnqvist, K ;
Jonsson, K ;
Aspenberg, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (01) :1-5
[25]  
LEESON MC, 1993, CLIN ORTHOP RELAT R, P239
[26]   Use of an injectable calcium phosphate bone cement in the treatment of tibial plateau fractures: A prospective study of twenty-six cases with twenty-month mean follow-up [J].
Lobenhoffer, P ;
Gerich, T ;
Witte, F ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (03) :143-149
[27]   Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement [J].
Mann, KA ;
Ayers, DC ;
Werner, FW ;
Nicoletta, RJ ;
Fortino, MD .
JOURNAL OF BIOMECHANICS, 1997, 30 (04) :339-346
[28]   Mixed-mode failure response of the cement-bone interface [J].
Mann, KA ;
Mocarski, R ;
Damron, LA ;
Allen, MJ ;
Ayers, DC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (06) :1153-1161
[29]   The reinforcement of cancellous bone screws with calcium phosphate cement [J].
Mermelstein, LE ;
Chow, LC ;
Friedman, C ;
Crisco, JJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (01) :15-20
[30]   Hip screw augmentation with an in situ setting calcium phosphate cement: An in vitro biomechanical analysis [J].
Moore, DC ;
Frankenburg, EP ;
Goulet, JA ;
Goldstein, SA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) :577-583