Predictors and outcomes of stroke after transcatheter aortic valve replacement

被引:8
作者
Hatfield, Sarah A. [1 ]
Nores, Marcos A. [2 ]
James, Taylor M. [1 ]
Rothenberg, Mark [2 ]
Kapila, Arvind [2 ]
Cubeddu, Roberto J. [2 ]
Stamou, Sotiris C. [2 ]
机构
[1] Univ Miami, Miller Sch Med, Undergrad Med Educ, Miami, FL 33136 USA
[2] JFK Med Ctr, Dept Cardiothorac Surg, 180 JFK Dr,Suite 320, Atlantis, FL 33462 USA
关键词
aortic stenosis; stroke; survival; transcatheter aortic valve replacement; valve replacement; CEREBRAL EMBOLIZATION; NEUROLOGIC EVENTS; IMPLANTATION; RISK; STENOSIS; BRAIN;
D O I
10.1111/jocs.14300
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Stroke is a devastating complication of transcatheter aortic valve replacement (TAVR). Many studies have investigated risk factors for postoperative stroke, but reliable predictors are not yet well-established. The objective of this study was to further characterize the predictors and outcomes of stroke after TAVR. Methods This is a retrospective cohort study of 1022 patients who underwent TAVR at a single institution between 2012 and 2018. Multivariable logistic regression analysis was used to identify independent predictors of postoperative stroke and Kaplan-Meier method to compare 1-year survival in patients with and without postoperative stroke. Results Postoperatively, 36 patients experienced a stroke (3.5%) with most developing multiple (63.9%, N = 23), and often bilateral infarcts (50.0%, N = 18). Stroke patients more commonly had peripheral arterial disease (P = .032) and carotid stenosis (P = .013) and were less likely to receive predeployment balloon aortic valvuloplasty (P = .005). Alternative access approach (odds ratio [OR], 2.322; 95% confidence interval [CI]: 1.067-5.054) and history of transient ischemic attack (OR, 2.373; 95% CI: 1.026-5.489) were identified as independent predictors of postoperative stroke. Stroke patients more frequently developed postoperative complications, including prolonged ventilation (P < .001), major vascular complications (P < .001), and new-onset dialysis (P < .001). Operative mortality was greater in stroke patients (19.4% vs 3.7%; P < .001), and 1-year Kaplan-Meier estimates revealed worsened survival (log-rank P = .002). Conclusions Alternative access approach and a history of transient ischemic attack emerged as independent predictors of postoperative stroke. Patients with stroke suffered more complications and had worse survival, underscoring the importance of characterizing the stroke risk in these patients.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 23 条
[1]   Influence of Transcatheter Aortic Valve Replacement Strategy and Valve Design on Stroke After Transcatheter Aortic Valve Replacement [J].
Athappan, Ganesh ;
Gajulapalli, R. Dilip ;
Sengodan, Prasanna ;
Bhardwaj, Anju ;
Ellis, Stephen G. ;
Svensson, Lars ;
Tuzcu, Emin Murat ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (20) :2101-2110
[2]   Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta-Analysis [J].
Bagur, Rodrigo ;
Kwok, Chun Shing ;
Nombela-Franco, Luis ;
Ludman, Peter F. ;
de Belder, Mark A. ;
Sponga, Sandro ;
Gunning, Mark ;
Nolan, James ;
Diamantouros, Pantelis ;
Teefy, Patrick J. ;
Kiaii, Bob ;
Chu, Michael W. A. ;
Mamas, Mamas A. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (06)
[3]   Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis [J].
Barbanti, Marco ;
Buccheri, Sergio ;
Rodes-Cabau, Josep ;
Gulino, Simona ;
Genereux, Philippe ;
Pilato, Gerlando ;
Dvir, Danny ;
Picci, Andrea ;
Costa, Giuliano ;
Tamburino, Corrado ;
Leon, Martin B. ;
Webb, John G. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 245 :83-89
[4]   Direct Transcatheter Heart Valve Implantation Versus Implantation With Balloon Predilatation Insights From the Brazilian Transcatheter Aortic Valve Replacement Registry [J].
Bernardi, Fernando L. M. ;
Ribeiro, Henrique B. ;
Carvalho, Luiz A. ;
Sarmento-Leite, Rogerio ;
Mangione, Jose A. ;
Lemos, Pedro A. ;
Abizaid, Alexandre ;
Grube, Eberhard ;
Rodes-Cabau, Josep ;
de Brito, Fabio S., Jr. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (08)
[5]   Increased Risk of Cerebral Embolization After Implantation of a Balloon-Expandable Aortic Valve Without Prior Balloon Valvuloplasty [J].
Bijuklic, Klaudija ;
Haselbach, Timo ;
Witt, Julian ;
Krause, Korff ;
Hansen, Lorenz ;
Gehrckens, Ralf ;
Riess, Friedrich-Christian ;
Schofer, Joachim .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (12) :1608-1613
[6]   Population-Wide Trends in Aortic Stenosis Incidence and Outcomes [J].
Bonow, Robert O. ;
Greenland, Philip .
CIRCULATION, 2015, 131 (11) :969-971
[7]   Transcatheter aortic valve replacement and stroke: a comprehensive review [J].
Davlouros, Periklis A. ;
Mplani, Virginia C. ;
Koniari, Ioanna ;
Tsigkas, Grigorios ;
Hahalis, George .
JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (01) :95-104
[8]   Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients [J].
Eggebrecht, Holger ;
Schmermund, Axel ;
Voigtlaender, Thomas ;
Kahlert, Philipp ;
Erbel, Raimund ;
Mehta, Rajendra H. .
EUROINTERVENTION, 2012, 8 (01) :129-138
[9]   The risk and extent of neurologic events are equivalent for high-risk patients treated with transcatheter or surgical aortic valve replacement [J].
Gleason, Thomas G. ;
Schindler, John T. ;
Adams, David H. ;
Reardon, Michael J. ;
Kleiman, Neal S. ;
Caplan, Louis R. ;
Conte, John V. ;
Deeb, G. Michael ;
Hughes, G. Chad, Jr. ;
Chenoweth, Sharla ;
Popma, Jeffrey J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (01) :85-95
[10]   Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study [J].
Kahlert, Philipp ;
Al-Rashid, Fadi ;
Doettger, Philipp ;
Mori, Kathrine ;
Plicht, Bjoern ;
Wendt, Daniel ;
Bergmann, Lars ;
Kottenberg, Eva ;
Schlamann, Marc ;
Mummel, Petra ;
Holle, Dagny ;
Thielmann, Matthias ;
Jakob, Heinz G. ;
Konorza, Thomas ;
Heusch, Gerd ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2012, 126 (10) :1245-+