Effect of operating conditions on the physical and chemical CO2 absorption through the PVDF hollow fiber membrane contactor

被引:141
作者
Mansourizadeh, A. [1 ]
Ismail, A. F. [1 ]
Matsuura, T. [2 ]
机构
[1] Univ Teknol Malaysia, Adv Membrane Technol Res Ctr AMTEC, Skudai 81310, Johor, Malaysia
[2] Univ Ottawa, Dept Chem & Biol Engn, Ind Membrane Res Inst, Ottawa, ON K1N 6N5, Canada
关键词
Porous PVDF hollow fiber membrane; CO2; absorption; Operating parameters; MASS-TRANSFER; CARBON-DIOXIDE; REMOVAL; SEPARATION; CAPTURE; LIQUIDS;
D O I
10.1016/j.memsci.2010.02.054
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Porous polyvinylidene fluoride (PVDF) hollow fiber membranes were fabricated via a wet phase-inversion process and used in the gas-liquid membrane contactor for physical and chemical CO2 absorption. Effect of different operating parameters such as absorbent temperature. CO2 pressure, absorbent flow rate and long-term operation on the CO2 flux of the membrane were investigated. The characterization results showed that the prepared membrane possess small pore size with high surface porosity and wetting resistance, which are favorable for gas absorption application. Results of CO2 absorption experiments revealed that in case of physical absorption with distilled water, CO2 solubility was the key parameter which significantly affected the membrane CO2 flux. A significant increase in the CO2 flux was observed by increasing CO2 pressure and decreasing the absorbent temperature. However, in case of chemical absorption with NaOH (1 M), the reaction rate was dominant, where the CO2 flux was significantly increased by increasing the absorbent temperature. It was also found that when the liquid contacted the outer skin layer of the hollow fiber membrane, the operation was stable at the same gas and liquid pressure without bubble formation in the liquid phase. In addition, the results of long-term study demonstrated that the membrane performance was maintained constant for long-term operation. The initial flux reduction was found to be about 30% within the 23 h of physical absorption, and 20% of gradual reduction within 80 h of chemical absorption. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 39 条
[1]  
[Anonymous], 2004, MEMBRANE TECHNOLOGY
[2]   Effect of membrane structure on mass-transfer in the membrane gas-liquid contacting process using microporous PVDF hollow fibers [J].
Atchariyawut, Supakorn ;
Feng, Chunsheng ;
Wang, Rong ;
Jiraratananon, Ratana ;
Liang, D. T. .
JOURNAL OF MEMBRANE SCIENCE, 2006, 285 (1-2) :272-281
[3]  
Danckwerts P.V., 1970, GAS LIQUID REACTIONS
[4]   CO2 absorption at elevated pressures using a hollow fiber membrane contactor [J].
Dindore, VY ;
Brilman, DWF ;
Feron, PHM ;
Versteeg, GF .
JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) :99-109
[5]   Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors [J].
Dindore, VY ;
Brilman, DWF ;
Geuzebroek, FH ;
Versteeg, GF .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) :133-145
[6]  
ESATO K, 1975, J THORAC CARDIOV SUR, V69, P690
[7]   CO2 separation with polyolefin membrane contactors and dedicated absorption liquids:: performances and prospects [J].
Feron, PHM ;
Jansen, AE .
SEPARATION AND PURIFICATION TECHNOLOGY, 2002, 27 (03) :231-242
[8]   THE KELVIN EQUATION AND THE CAPILLARY CONDENSATION OF WATER [J].
FISHER, LR ;
GAMBLE, RA ;
MIDDLEHURST, J .
NATURE, 1981, 290 (5807) :575-576
[9]   Hollow fiber membrane contactors [J].
Gabelman, A ;
Hwang, ST .
JOURNAL OF MEMBRANE SCIENCE, 1999, 159 (1-2) :61-106
[10]   Capturing greenhouse gases [J].
Herzog, H ;
Eliasson, B ;
Kaarstad, O .
SCIENTIFIC AMERICAN, 2000, 282 (02) :72-79