CARBON MONOXIDE AND NITRIC OXIDE CONCENTRATIONS IN FLUE GAS DURING COMBUSTION OF AGRICULTURAL BIOMASS IN THE RESIDENTAL BOILER

被引:4
作者
Palaszynska, Katarzyna [1 ]
Juszczak, Marek [1 ]
Ostrowski, Ryszard [1 ]
机构
[1] Poznan Univ Tech, Inst Environm Engn, Div Heating Air Conditioning & Air Protect, Poznan, Poland
来源
DREWNO | 2021年 / 64卷 / 207期
关键词
agricultural biomass; combustion; emission; boiler; rotary furnace; POLLUTANT CONCENTRATIONS; CHEMICAL-COMPOSITION; PELLET BOILER; EMISSIONS; TECHNOLOGIES; NITROGEN; SYSTEMS;
D O I
10.12841/wood.1644-3985.356.01
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Concentrations of carbon monoxide and nitric oxide (in mg/m(3) and presented for 10% O-2) in the flue gas from firing hay and palm kernel shell pellets, as well as a mixture of coffee husk pellets and wood pellets at the weight ratios of 70:30 and 30:70 in a rotary furnace with a 20 kW nominal heat output amounted to: 695.102; 3492.271; 2921.165; 18344.244; 5297.315, respectively, for the boiler operating with minimum heat output, and 568.192; 2400.341; 4065.275; 20696.380 and 2272.123, respectively, for the boiler operating at a heat output close to maximum. The value of carbon monoxide concentration was proportional to the amount of slag generated during the combustion process and the value of nitric oxide concentration was proportional to the nitrogen content in the fuel. Variation of parameters in time: temperature in the combustion chamber, carbon monoxide and nitric oxide concentrations, oxygen concentration and air excess ratio while firing wood and agricultural biomass pellets were indicated. Correlation between nitric oxide and carbon monoxide concentrations as well as carbon monoxide and nitric oxide concentration versus oxygen concentration and temperature in the combustion chamber were presented. Agricultural biomass pellets should be mixed with wood pellets to improve combustion process and reduce carbon monoxide and nitric oxide concentrations. Pollutant concentration measurements were performed in real-life conditions resembling the ones experienced by boiler end-users.
引用
收藏
页码:125 / 144
页数:20
相关论文
共 43 条
[1]  
[Anonymous], 2006, MODELLING COMBUSTION
[2]   Characterization and modeling of pyrolysis of the two-phase olive mill solid waste [J].
Blazquez Garcia, Gabriel ;
Calero de Hoces, Monica ;
Martinez Garcia, Carmen ;
Cotes Palomino, Maria Teresa ;
Ronda Galvez, Alicia ;
Angeles Martin-Lara, Maria .
FUEL PROCESSING TECHNOLOGY, 2014, 126 :104-111
[3]   Stove Performance and Emission Characteristics in Residential Wood Log and Pellet Combustion, Part 1: Pellet Stoves [J].
Boman, Christoffer ;
Pettersson, Esbjorn ;
Westerholm, Roger ;
Bostrom, Dan ;
Nordin, Anders .
ENERGY & FUELS, 2011, 25 (01) :307-314
[4]   An experimental approach to the chemical properties and the ash melting behavior in agricultural biomass [J].
Cioabla, Adrian Eugen ;
Pop, Nicolina ;
Calinoiu, Delia Gabriela ;
Trif-Tordai, Gavrila .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 121 (01) :421-427
[5]   Extensive Operating Experiments on the Conversion of Fuel-Bound Nitrogen into Nitrogen Oxides in the Combustion of Wood Fuel [J].
Dzurenda, Ladislav ;
Hroncova, Emilia ;
Ladomersky, Juraj .
FORESTS, 2017, 8 (01)
[6]  
Dzurenda L, 2015, POL J ENVIRON STUD, V24, P505
[7]  
Francisco Josephinum, 2010, PELLETS COMPACT ETA
[8]  
Garcia-Cuevas M.T., 2011, 19 EUR BIOM C EXH BE 19 EUR BIOM C EXH BE
[9]   Effect of Excess Air Ratio and Temperature on NOx Emission from Grate Combustion of Biomass in the Staged Air Combustion Scenario [J].
Houshfar, Ehsan ;
Skreiberg, Oyvind ;
Lovas, Terese ;
Todorovic, Dusan ;
Sorum, Lars .
ENERGY & FUELS, 2011, 25 (10) :4643-4654
[10]   Emission characteristics of modern and old-type residential boilers fired with wood logs and wood pellets [J].
Johansson, LS ;
Leckner, B ;
Gustavsson, L ;
Cooper, D ;
Tullin, C ;
Potter, A .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (25) :4183-4195