PET/CT imaging for treatment verification after proton therapy: A study with plastic phantoms and metallic implants

被引:123
作者
Parodi, Katia
Paganetti, Harald
Cascio, Ethan
Flanz, Jacob B.
Bonab, Ali A.
Alpert, Nathaniel M.
Lohmann, Kevin
Bortfeld, Thomas
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Siemens Med Solut USA, Mol Imaging, Knoxville, TN 37932 USA
关键词
proton therapy; positron emission tomography; Monte Carlo;
D O I
10.1118/1.2401042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of off-line positron emission tomography/computed tomography (PET/CT) for routine three dimensional in-vivo treatment verification of proton radiation therapy is currently under investigation at Massachusetts General Hospital in Boston. In preparation for clinical trials, phantom experiments were carried out to investigate the sensitivity and accuracy of the method depending on irradiation and imaging parameters. Furthermore, they addressed the feasibility of PET/CT as a robust verification tool in the presence of metallic implants. These produce x-ray CT artifacts and fluence perturbations which may compromise the accuracy of treatment planning algorithms. Spread-out Bragg peak proton fields were delivered to different phantoms consisting of polymethylmethacrylate (PMMA), PMMA stacked with lung and bone equivalent materials, and PMMA with titanium rods to mimic implants in patients. PET data were acquired in list mode starting within 20 min after irradiation at a commercial luthetium-oxyorthosilicate (LSO)-based PET/CT scanner. The amount and spatial distribution of the measured activity could be well reproduced by calculations based on the GEANT4 and FLUKA Monte Carlo codes. This phantom study supports the potential of millimeter accuracy for range monitoring and lateral field position verification even after low therapeutic dose exposures of 2 Gy, despite the delay between irradiation and imaging. It also indicates the value of PET for treatment verification in the presence of metallic implants, demonstrating a higher sensitivity to fluence perturbations in comparison to a commercial analytical treatment planning system. Finally, it addresses the suitability of LSO-based PET detectors for hadron therapy monitoring. This unconventional application of PET involves countrates which are orders of maonitude lower than in diagnostic tracer imaging, i.e., the signal of interest is comparable to the noise originating from the intrinsic radioactivity of the detector itself. In addition to PET alone, PET/CT imaging provides accurate information on the position of the imaged object and may assess possible anatomical changes during fractionated radiotherapy in clinical applications. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:419 / 435
页数:17
相关论文
共 44 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] ALBERTINI F, 2006, PART THER COOP GROUP, P61
  • [3] SPALLATION DE LOXYGENE PAR DES PROTONS DE 20 A 150 MEV
    ALBOUY, MG
    COHEN, JP
    GUSAKOW, M
    POFFE, N
    SERGOLLE, H
    VALENTIN, L
    [J]. PHYSICS LETTERS, 1962, 2 (07): : 306 - 307
  • [4] [Anonymous], 2001, IAEATECDOC1211
  • [5] Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research
    Antonuk, LE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) : R31 - R65
  • [6] BERGER MJ, 1993, 5226 NISTIR PHYS LAB
  • [7] TREATMENT PLANNING FOR HEAVY-ION RADIOTHERAPY
    CHEN, GTY
    SINGH, RP
    CASTRO, JR
    LYMAN, JT
    QUIVEY, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (10): : 1809 - 1819
  • [8] First experimental results of time-of-flight reconstruction on an LSO PET scanner
    Conti, M
    Bendriem, B
    Casey, M
    Chen, M
    Kehren, F
    Michel, C
    Panin, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) : 4507 - 4526
  • [9] Positron emission tomography for quality assurance of cancer therapy with light ion beams
    Enghardt, W.
    Debus, J.
    Haberer, T.
    Hasch, B. G.
    Hinz, R.
    Jaekel, O.
    Kraemer, M.
    Lauckner, K.
    Pawelke, J.
    Poenisch, F.
    [J]. NUCLEAR PHYSICS A, 1999, 654 (01) : 1047C - 1050C
  • [10] Dose quantification from in-beam positron emission tomography
    Enghardt, W
    Parodi, K
    Crespo, P
    Fiedler, F
    Pawelke, J
    Pönisch, F
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S96 - S98