Non-invasive assessment of liver fibrosis using acoustic structure quantification: comparison with transient elastography in chronic viral hepatitis

被引:6
作者
Nam, Tae-Hoon [1 ]
Park, Beom Jin [1 ]
Sung, Deuk Jae [1 ]
Kim, Min Ju [1 ]
Han, Na Yeon [1 ]
Sim, Ki Choon [1 ]
Lee, Jean H. [2 ]
Cho, Sung Bum [1 ]
机构
[1] Korea Univ, Coll Med, Anam Hosp, Dept Radiol, 126-1 5 Ka, Seoul 136705, South Korea
[2] Univ Washington, Med Ctr, Dept Radiol, Seattle, WA 98195 USA
关键词
Liver fibrosis; Acoustic structure quantification (ASQ); Ultrasound; Transient elastography (TE); PLATELET RATIO INDEX; ASPARTATE-AMINOTRANSFERASE; DIAGNOSTIC-ACCURACY; ULTRASOUND; BIOPSY; FIB-4; PREDICTION; CIRRHOSIS; ECHO; FIBROSCAN(R);
D O I
10.1007/s00261-015-0597-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the diagnostic efficacy of acoustic structure quantification (ASQ) parameters [mode, average, and focal distribution (FD) ratio] in the staging of hepatic fibrosis in patients with chronic viral hepatitis and to compare it with transient elastography (TE) by using liver biopsy as reference standard. Methods: We studied 62 patients with chronic viral hepatitis. Each patient underwent ASQ evaluation and liver biopsy; 54 of these patients received TE. Thirty-six participants without any liver disease were enrolled as normal group, who also underwent ASQ evaluation and TE. All three parameters of ASQ were compared with the histologic fibrosis grade according to the METAVIR scoring (F0-F4). Statistical analysis was performed to investigate the correlations and the diagnostic values of ASQ parameters and compare them to TE. Results: All three ASQ parameters and TE were significantly correlated with liver fibrosis stage. Of the ASQ parameters, the mode parameter showed the best correlation (P < 0.001). On the area under the receiver operating characteristic curve (AUROC), the mode parameter of ASQ analysis showed both significant correlation and good accuracy for diagnosis of F >= 1, F >= 2, and F >= 3. These values were significantly better than those of the average and FD ratio parameters in F >= 1 and F >= 2 (P < 0.05). There was no statistically significant difference in AUROC between the mode parameter and TE in diagnosis of F >= 1, F >= 2, or F >= 3. Conclusions: The mode parameter is the most reliable ASQ parameter, comparable to TE, as a non-invasive method for the detection and grading of liver fibrosis in patients with chronic viral hepatitis.
引用
收藏
页码:239 / 247
页数:9
相关论文
共 48 条
[11]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[12]   The role of liver biopsy in chronic hepatitis C [J].
Dienstag, JL .
HEPATOLOGY, 2002, 36 (05) :S152-S160
[13]   Clinical evidence for the regression of liver fibrosis [J].
Ellis, Elizabeth L. ;
Mann, Derek A. .
JOURNAL OF HEPATOLOGY, 2012, 56 (05) :1171-1180
[14]   WFUMB GUIDELINES AND RECOMMENDATIONS FOR CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 3: LIVER [J].
Ferraioli, Giovanna ;
Filice, Carlo ;
Castera, Laurent ;
Choi, Byung Ihn ;
Sporea, Ioan ;
Wilson, Stephanie R. ;
Cosgrove, David ;
Dietrich, Christoph F. ;
Amy, Dominique ;
Bamber, Jeffrey C. ;
Barr, Richard ;
Chou, Yi-Hong ;
Ding, Hong ;
Farrokh, Andre ;
Friedrich-Rust, Mireen ;
Hall, Timothy J. ;
Nakashima, Kazutaka ;
Nightingale, Kathryn R. ;
Palmeri, Mark L. ;
Schafer, Fritz ;
Shiina, Tsuyoshi ;
Suzuki, Shinichi ;
Kudo, Masatoshi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) :1161-1179
[15]   Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Dal Bello, Barbara ;
Zicchetti, Mabel ;
Filice, Gaetano ;
Filice, Carlo .
HEPATOLOGY, 2012, 56 (06) :2125-2133
[16]   Etiology-related determinants of liver stiffness values in chronic viral hepatitis B or C [J].
Fraquelli, Mirella ;
Rigamonti, Cristina ;
Casazza, Giovanni ;
Donato, Maria Francesca ;
Ronchi, Guido ;
Conte, Dario ;
Rumi, Mariagrazia ;
Lampertico, Pietro ;
Colombo, Massimo .
JOURNAL OF HEPATOLOGY, 2011, 54 (04) :621-628
[17]   Performance of transient elastography for the staging of liver fibrosis: A meta-analysis [J].
Friedrich-Rust, Mireen ;
Ong, Mei-Fang ;
Martens, Swantje ;
Sarrazin, Christoph ;
Bojunga, Joerg ;
Zeuzem, Stefan ;
Herrmann, Eva .
GASTROENTEROLOGY, 2008, 134 (04) :960-974
[18]   Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[19]   Diagnosis, Management, and Treatment of Hepatitis C: An Update [J].
Ghany, Marc G. ;
Strader, Doris B. ;
Thomas, David L. ;
Seeff, Leonard B. .
HEPATOLOGY, 2009, 49 (04) :1335-1374
[20]   Retrospective study of FibroScan®, APRI, FIB-4 and FORNS indexes compared with liver biopsy in the evaluation of liver fibrosis in patients with chronic hepatitis C monoinfection and HIV coinfection [J].
Gonzalez Guilabert, Maria Isabel ;
Hinojosa Mena-Bernal, Carmen ;
del Pozo Gonzalez, Jorge ;
del Pozo Perez, Miguel Angel .
GASTROENTEROLOGIA Y HEPATOLOGIA, 2010, 33 (06) :425-432