In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations

被引:56
作者
Karl, Matthias
Graef, Friedrich
Taylor, Thomas D.
Heckmann, Siegfried M.
机构
[1] Univ Erlangen Nurnberg, Sch Dent Med, Inst Appl Math, D-91054 Erlangen, Germany
[2] Univ Connecticut, Dept Prosthodont, Storrs, CT 06269 USA
[3] Univ Erlangen Nurnberg, Dept Prosthodont, D-91054 Erlangen, Germany
关键词
D O I
10.1016/j.prosdent.2007.01.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. In implant prosthodontics, restorations can either be cement- or screw-retained. Aside from passivity of fit, esthetics, and retrievability, the occlusal opening of the screw-access hole (SAH) is a major difference between the 2 types of restorations. In veneered fixed partial dentures (FPDs), the SAH forms a discontinuity of the ceramic layer and may be an origin for chipping fractures. Purpose. The objective of this study was to investigate whether more chipping fractures Occur during dynamic loading on the occlusal surface of screw-retained ceramic-veneered implant FPDs than in cement-retained restorations. Material and methods. Ten cement-retained and 10 screw-retained ceramic veneered 5-unit FPDs were manufactured for a 3-implant situation. A masticatory, simulator was used for loading the occlusal surface of the FPDs to the implant positions for 20,000 cycles with a force of 100 N applied for 1 second followed by 1 second of no loading. For analysis, 3 clinicians evaluated the FPDS using a light microscope and a dental probe. The numbers of chipping fractures found were analyzed by means of a generalized linear model with Poisson response (alpha=.05). Results. The investigators found significantly more chipping fractures in the group of screw-retained FPDs, the rate ratio of screw-retained FPDs versus cement-retained FPDs being greater than 1 with a P value of .0023. Conclusion. The SAH of screw-retained implant FPDs forms a weak point of the ceramic layer.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 20 条
[1]   Fatigue of restorative materials [J].
Baran, G ;
Boberick, K ;
McCool, J .
CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 2001, 12 (04) :350-360
[2]   Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function [J].
Brägger, U ;
Aeschlimann, S ;
Bürgin, W ;
Hämmerle, CHF ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :26-34
[3]  
Chee W, 1999, INT J ORAL MAX IMPL, V14, P137
[4]   LONG-TERM CLINICAL-STUDY OF PORCELAIN-FUSED-TO-GOLD RESTORATIONS [J].
COORNAERT, J ;
ADRIAENS, P ;
DEBOEVER, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (03) :338-342
[5]  
Denehy G, 1998, Dent Clin North Am, V42, P719
[6]   Detection of microscopic cracks in dental ceramic materials by fluorescent penetrant method [J].
Fischer, H ;
Karaca, F ;
Marx, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (01) :153-158
[7]   Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry [J].
Hebel, KS ;
Gajjar, RC .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (01) :28-35
[8]   Cement fixation and screw retention:: parameters of passive fit -: An in vitro study of three-unit implant-supported fixed partial dentures [J].
Heckmann, SM ;
Karl, M ;
Wichmann, MG ;
Winter, W ;
Graef, F ;
Taylor, TD .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :466-473
[9]  
Johansson LÅ, 2003, INT J PROSTHODONT, V16, P172
[10]   Static implant loading caused by as-cast metal and ceramic-veneered superstructures [J].
Karl, M ;
Rosch, S ;
Graef, F ;
Taylor, TD ;
Heckmann, SM .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (04) :324-330