Transferring the south solar energy to the north facade through embedded water pipes

被引:40
作者
Ibrahim, Mohamad [1 ]
Wurtz, Etienne [2 ]
Biwole, Pascal Henry [1 ,3 ]
Achard, Patrick [1 ]
机构
[1] PSL Res Univ, Ctr Proc Energies Renouvelables & Syst Energet, MINES ParisTech, PERSEE, F-06904 Sophia Antipolis, France
[2] CEA, INES, LEB Bldg Energy Lab, F-73377 Le Bourget Du Lac, France
[3] Univ Nice Sophia Antipolis, Dept Math & Interact, F-06189 Nice, France
关键词
Active embedded-pipe envelope; South solar energy transfer to the north facade; Co-simulation; BCVTB; Numerical model; Silica aerogel insulation; BUILDING SYSTEMS; PERFORMANCE; SIMULATION; STORAGE; DESIGN; MODELS;
D O I
10.1016/j.energy.2014.10.078
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the cold sunny winter days, when the south wall is well insulated, a significant amount of solar energy falling on this facade is not transferred to the inside. In this study, a novel closed wall-loop system is proposed to capture this wasted energy available during non-cloudy winter days and transfer it to the cooler north facade through water pipes embedded in an exterior aerogel-based insulating coating. The coating's projection technique through spraying or plastering allows the easy implementation of this system. We present the proposed system with all the mathematical equations and numerical model. This model is then validated against experimental data found in the literature. To test its performance on a full-scale house, this MATLAB numerical model is coupled to the whole building energy simulation program EnergyPlus through co-simulation. Results show that the reductions in the annual heating load for the house adopting this system relative to the one without it are between 28 and 43% for new houses and 15-20% for old houses for Mediterranean climate. For other climates, the reductions vary between 6% and 26%. The heat losses through the north facade are reduced by about 60-88% in the Mediterranean climate and about 20-50% in the other climates. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:834 / 845
页数:12
相关论文
共 50 条
[1]   Simulated and experimental performance of a heat pipe assisted solar wall [J].
Albanese, Michael V. ;
Robinson, Brian S. ;
Brehob, Ellen G. ;
Sharp, M. Keith .
SOLAR ENERGY, 2012, 86 (05) :1552-1562
[2]  
[Anonymous], 2001, International Weather for Energy Calculations (IWEC Weather Files)
[3]  
[Anonymous], 2011, ENERGYPLUS V 7 0 0
[4]  
[Anonymous], LBNL4420E
[5]  
[Anonymous], 2012, BCVTB V 1 1 0
[6]  
[Anonymous], 2011, MATLAB V R2011A
[7]   Mixed convection from heated room surfaces [J].
Awbi, HB ;
Hatton, A .
ENERGY AND BUILDINGS, 2000, 32 (02) :153-166
[8]   Toward a positive-net-energy residential building in Serbian conditions [J].
Bojic, Milorad ;
Nikolic, Novak ;
Nikolic, Danijela ;
Skerlic, Jasmina ;
Miletic, Ivan .
APPLIED ENERGY, 2011, 88 (07) :2407-2419
[9]   Energy demands and potential savings in European office buildings: Case studies based on EnergyPlus simulations [J].
Boyano, A. ;
Hernandez, P. ;
Wolf, O. .
ENERGY AND BUILDINGS, 2013, 65 :19-28
[10]  
Cengel Y.A., 2005, Heat transfer: a practical approach