Single center experience with ultrasound guided axillary vein port placement

被引:5
作者
Tivnan, Patrick [1 ]
Nannery, Micaela [2 ]
Epelboym, Yan [1 ]
Vilvendhan, Rajendran [1 ]
机构
[1] Boston Med Ctr, Dept Radiol, 840 Harrison Ave 4th Floor, Boston, MA 02118 USA
[2] Boston Univ, Sch Med, Boston, MA 02118 USA
关键词
Oncology access; interventional radiology; PORT-A-Cath; subclavian vein; implantable port; VENOUS ACCESS PORTS; SUBCLAVIAN VEIN; RETROSPECTIVE ANALYSIS; SYSTEMS; INSERTION; SURGEON;
D O I
10.1177/11297298211008094
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To retrospectively review a single institution experience of ultrasound guided axillary vein port placement. Methods: In this retrospective study, a patient list was generated after searching our internal database from 1/1/2012 to 10/1/2018. Patients who had undergone axillary vein port placement were included. Chart review was performed to confirm approach, laterality and to gather demographic data, clinical indications, technical outcomes, and complications. Descriptive statistics were used to analyze this cohort. Chi-square statistics were used to compare outcomes by laterality. Results: Three hundred seven patients (51% female) with an average age of 58 years were included. The port was placed via the right axillary vein in 85% (261/307), predominantly for the indication of chemotherapy access (296/307). Technical success was achieved in all 307 cases. Peri procedural complications occurred in 1% (4/307) of cases and included port malpositioning requiring replacement and a case of port pocket hematoma. Post procedural complications including deep vein thrombosis and port malfunction occurred in 17% (52/307) of cases and port removal as a result of complication occurred in 9% (29/307) of cases. Conclusions: Ultrasound guided placement of an axillary port is a safe procedure to perform and demonstrates good clinical outcomes.
引用
收藏
页码:706 / 709
页数:4
相关论文
共 50 条
  • [31] Clinical outcomes of totally implantable venous access port placement via the axillary vein in patients with head and neck malignancy
    Hong, Sun
    Seo, Tae-Seok
    Song, Myung Gyu
    Seol, Hae-Young
    Suh, Sang Il
    Ryoo, In-Seon
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (02) : 134 - 139
  • [32] Real-time ultrasound-guided axillary vein cannulation in children: a randomised controlled trial
    Kim, E. -H.
    Lee, J. -H.
    Song, I. -K.
    Kim, H. -S.
    Jang, Y. -E.
    Choi, S. -N.
    Kim, J. -T.
    ANAESTHESIA, 2017, 72 (12) : 1516 - 1522
  • [33] Ultrasound-Guided Subclavian Vein Cannulation in Low Birth Weight Neonates
    Lausten-Thomsen, Ulrik
    Merchaoui, Zied
    Dubois, Cecile
    Trolli, Sergio Eleni Dit
    Le Sache, Nolwenn
    Mokhtari, Mostafa
    Tissieres, Pierre
    PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (02) : 172 - 175
  • [34] Highlights on Ultrasound-Guided Subclavian Vein Access
    Noriaki Sakamoto
    Yasuaki Arai
    Yoshito Takeuchi
    Masahide Takahashi
    Masakatsu Tsurusaki
    Kazuro Sugimura
    CardioVascular and Interventional Radiology, 2011, 34 : 215 - 216
  • [35] Ultrasound-guided subclavian vein catheterization: Beyond just the jugular vein
    Bodenham, Andrew R.
    CRITICAL CARE MEDICINE, 2011, 39 (07) : 1819 - 1820
  • [36] Highlights on Ultrasound-Guided Subclavian Vein Access
    Sakamoto, Noriaki
    Arai, Yasuaki
    Takeuchi, Yoshito
    Takahashi, Masahide
    Tsurusaki, Masakatsu
    Sugimura, Kazuro
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (01) : 215 - 216
  • [37] Central venous port implantations via the cephalic vein applying an intravasal electrographic control of the catheter tip position: a single-center experience of 316 cases
    Marcus Schenck
    Tim Schneider
    Herbert Rübben
    Andreas Eisenhardt
    World Journal of Urology, 2012, 30 : 399 - 404
  • [38] How should urologists perform implantation of subcutaneous central venous port systems? A single center experience of 347 cases.
    Schenck, M.
    Michels-Oswald, W.
    Tschirdewahn, S.
    Ruebben, H.
    vom Dorp, F.
    Rose, A.
    Panic, A.
    Niedworok, C.
    Rossi, R.
    UROLOGE, 2012, 51 (02): : 226 - +
  • [39] Influence of arm position on catheter placement during real-time ultrasound-guided right infraclavicular proximal axillary venous catheterization
    Ahn, J. H.
    Kim, I. S.
    Shin, K. M.
    Kang, S. S.
    Hong, S. J.
    Park, J. H.
    Kim, H. J.
    Lee, S. H.
    Kim, D. Y.
    Jung, J. H.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (03) : 363 - 369
  • [40] Ultrasound-Guided Venous Catheter Placement in Prone Position
    Yu, Kuan-Pen
    Wang, Tzu-Chun
    Kung, Yu-Chung
    Cheng, Kuang-Hua
    JOURNAL OF INTENSIVE CARE MEDICINE, 2025, 40 (01) : 94 - 108