Reproducibility of Dynamic Contrast-Enhanced MRI in Renal Cell Carcinoma A Prospective Analysis on Intra- and Interobserver and Scan-Rescan Performance of Pharmacokinetic Parameters

被引:9
作者
Wang, Haiyi [1 ]
Su, Zihua [2 ,4 ]
Ye, Huiyi [1 ]
Xu, Xiao [3 ]
Sun, Zhipeng [2 ,4 ]
Li, Lu [1 ]
Duan, Feixue [5 ]
Song, Yuanyuan [6 ]
Lambrou, Tryphon [7 ]
Ma, Lin [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] GE Healthcare, Adv Applicat, Beijing, Peoples R China
[3] GE Healthcare, Adv Applicat, Shanghai, Peoples R China
[4] Zhangjiakou First Hosp, Dept Radiol, Zhangjiakou City, Hebei Province, Peoples R China
[5] Jiayuguan Jiugang Hosp, Med Imaging Ctr, Jiayuguan City, Gansu, Peoples R China
[6] Gen Hosp Pingdingshan Coal Grp, Dept Radiol, Pingdingshan City, Henan Province, Peoples R China
[7] Lincoln Univ, Lincoln Sch Comp Sci, Lincon, England
关键词
ARTERIAL INPUT FUNCTION; DCE-MRI; ACCURACY; CANCER; REGION; REGISTRATION; VARIABILITY; SORAFENIB; TUMORS; TISSUE;
D O I
10.1097/MD.0000000000001529
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to investigate the intra- and interobserver as well as scan-rescan reproducibility of quantitative parameters of renal cell carcinomas (RCCs) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).A total of 21 patients with clear cell RCCs (17 men, 4 woman; age 37-69 years, mean age 54.6 years, mean size, 5.02.2cm) were prospectively recruited from September 2012 to November 2012. Patients underwent paired DCE-MRI studies on a 3.0 T MR system with an interval of 48 to 72 hours. The extended-Tofts model and population-based arterial input function were used to calculate kinetic parameters. Three observers defined the 2-dimensional whole-tumor region of interest at the slice with the maximum diameter of the RCC. Intraobserver and scan-rescan differences were assessed using paired t tests, whereas interobserver differences using two-way analysis of variance. Intra- and interobserver reproducibility and scan-rescan reproducibility were evaluated using within-subject coefficient of variation (wCoV) and intraclass correlation coefficient (ICC).There were no significant intra-, interobserver, or scan-rescan differences in parameters (all P>0.05). All ICCs for intra- and interobserver agreements were >0.75 (P<0.05), whereas the scan-rescan agreement was moderate to good; V-e (0.764, 95% confidence interval [CI]: 0.378-0.925) and K-ep (0.906, 95% CI: 0.710-0.972) had higher ICC than K-trans (0.686; 95% CI: 0.212-0.898) and V-p (0.657; 95% CI: 0.164-0.888). In intra- and interobserver variability analyses, all parameters except V-p had low wCoV values. K-trans and V-e had slightly lower intraobserver wCoV (1.2% and 0.9%) compared with K-ep (3.7%), whereas all 3 of these parameters had similar interobserver wCoV values (2.5%, 3.1%, and 2.9%, respectively). Regarding scan-rescan variability, K-trans and K-ep showed slightly higher variation (15.6% and 15.4%) than V-e (10.1%). V-p had the largest wCoV in all variability analyses (all >30%).DCE-MRI demonstrated good intra- and interobserver reproducibility and moderate to good scan-rescan performance in the assessment of RCC using K-trans, K-ep, and V-e as parameters under noncontinuous scanning mode. V-p showed poor reproducibility, and thus may not be suitable for this scanning protocol.
引用
收藏
页数:8
相关论文
共 46 条
[1]   Pancreatic Cancer: Utility of Dynamic Contrast-enhanced MR Imaging in Assessment of Antiangiogenic Therapy [J].
Akisik, M. Fatih ;
Sandrasegaran, Kumaresan ;
Bu, Guixue ;
Lin, Chen ;
Hutchins, Gary D. ;
Chiorean, Elena G. .
RADIOLOGY, 2010, 256 (02) :441-449
[2]   Tumoral and Nontumoral Pancreas: Correlation between Quantitative Dynamic Contrast-enhanced MR Imaging and Histopathologic Parameters [J].
Bali, Maria A. ;
Metens, Thierry ;
Denolin, Vincent ;
Delhaye, Myriam ;
Demetter, Pieter ;
Closset, Jean ;
Matos, Celso .
RADIOLOGY, 2011, 261 (02) :456-466
[3]   Inter- and intraobserver variability in the evaluation of dynamic breast cancer MRI [J].
Beresford, Mark J. ;
Padhani, Anwar R. ;
Taylor, N. Jane ;
Ah-See, Mei-Lin ;
Stirling, J. James ;
Makris, Andreas ;
d'Arcy, James A. ;
Collins, David J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :1316-1325
[4]  
Braunagel M, 2015, INVEST RADIOL, V50, P57, DOI 10.1097/RLI.0000000000000096
[6]   High Temporal Resolution 3D Gadolinium-Enhanced Dynamic MR Imaging of Renal Tumors with Pharmacokinetic Modeling: Preliminary Observations [J].
Chandarana, Hersh ;
Amarosa, Alana ;
Huang, William C. ;
Kang, Stella K. ;
Taneja, Samir ;
Melamed, Jonathan ;
Kim, Sungheon .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (04) :802-808
[7]   The importance of AIF ROI selection in DCE-MRI renography: Reproducibility and variability of renal perfusion and filtration [J].
Cutajar, M. ;
Mendichovszky, I. A. ;
Tofts, P. S. ;
Gordon, I. .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :E155-E161
[8]   Inter- and intra-rater reproducibility of quantitative dynamic contrast enhanced MRI using TWIST perfusion data in a uterine fibroid model [J].
Davenport, Matthew S. ;
Heye, Tobias ;
Dale, Brian M. ;
Horvath, Jeffrey J. ;
Breault, Steven R. ;
Feuerlein, Sebastian ;
Bashir, Mustafa R. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) :329-335
[9]   Dynamic Contrast-Enhanced MRI of the Breast: Quantitative Method for Kinetic Curve Type Assessment [J].
El Khouli, Riham H. ;
Macura, Katarzyna J. ;
Jacobs, Michael A. ;
Khalil, Tarek H. ;
Kamel, Ihab R. ;
Dwyer, Andrew ;
Bluemke, David A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :W295-W300
[10]   Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging [J].
Engelbrecht, MR ;
Huisman, HJ ;
Laheij, RJF ;
Jager, GJ ;
van Leenders, GJLH ;
Hulsbergen-Van De Kaa, CA ;
de la Rosette, JJMCH ;
Blickman, JG ;
Barentsz, JO .
RADIOLOGY, 2003, 229 (01) :248-254