Development and validation of a correction equation for Corvis tonometry

被引:127
作者
Joda, Akram Abdelazim [1 ,2 ]
Shervin, Mir Mohi Sefat [3 ]
Kook, Daniel [4 ]
Elsheikh, Ahmed [1 ,5 ,6 ]
机构
[1] Univ Liverpool, Sch Engn, Liverpool L69 3BX, Merseyside, England
[2] King Faisal Univ, Dept Mech Engn, Coll Engn, Al Hasa, Saudi Arabia
[3] Smile Eyes Clin, Munich, Germany
[4] Univ Munich, Dept Ophthalmol, Munich, Germany
[5] Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr Ophthalmol, London, England
[6] UCL Inst Ophthalmol, London, England
基金
英国工程与自然科学研究理事会; 美国国家卫生研究院;
关键词
intraocular pressure; ocular biomechanics; Tonometry; Corvis ST; cornea; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE MEASUREMENT; GOLDMANN APPLANATION TONOMETRY; BIOMECHANICAL PROPERTIES; AXIAL LENGTH; HUMAN SCLERA; HUMAN EYE; TONO-PEN; AGE; CURVATURE;
D O I
10.1080/10255842.2015.1077515
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Primary objective: This study uses numerical analysis and validation against clinical data to develop a method to correct intraocular pressure (IOP) measurements obtained using the Corvis Tonometer for the effects of central corneal thickness (CCT), and age. Materials and Methods: Finite element analysis was conducted to simulate the effect of tonometric air pressure on the intact eye globe. The analyses considered eyes with wide variations in IOP (10-30mmHg), CCT (445-645 microns), R (7.2-8.4mm), shape factor, P (0.6-1) and age (30-90years). In each case, corneal deformation was predicted and used to estimate the IOP measurement by Corvis (CVS-IOP). Analysis of the results led to an algorithm relating estimates of true IOP as a function of CVS-IOP, CCT and age. All other parameters had negligible effect on CVS-IOP and have therefore been omitted from the algorithm. Predictions of corrected CVS-IOP, as obtained by applying the algorithm to a clinical data-set involving 634 eyes, were assessed for their association with the cornea stiffness parameters; CCT and age. Results: Analysis of CVS-IOP measurements within the 634-large clinical data-set showed strong correlation with CCT (3.06mmHg/100microns, r(2)=0.204) and weaker correlation with age (0.24mmHg/decade, r(2)=0.009). Applying the algorithm to IOP measurements resulted in IOP estimations that became less correlated with both CCT (0.04mmHg/100microns, r(2)=0.005) and age (0.09mmHg/decade, r(2)=0.002). Conclusions: The IOP correction process developed in this study was successful in reducing reliance of IOP measurements on both corneal thickness and age in a healthy European population.
引用
收藏
页码:943 / 953
页数:11
相关论文
共 33 条
[1]  
Ambrosio Renato Jr, 2011, Int Ophthalmol Clin, V51, P11, DOI 10.1097/IIO.0b013e31820f1d2d
[2]  
[Anonymous], ISO8612
[3]   The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology [J].
Browning, AC ;
Bhan, A ;
Rotchford, AP ;
Shah, S ;
Dua, HS .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (11) :1395-1399
[4]   Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry [J].
Davey, P. G. ;
Elsheikh, A. ;
Garway-Heath, D. F. .
EYE, 2013, 27 (05) :621-629
[5]   The asphericity, curvature and tilt of the human cornea measured using a videokeratoscope [J].
Douthwaite, WA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (02) :141-150
[6]   The EyeSys videokeratoscopic assessment of apical radius and p-value in the normal human cornea [J].
Douthwaite, WA ;
Hough, T ;
Edwards, K ;
Notay, H .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1999, 19 (06) :467-474
[7]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[8]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[9]   Stress free configuration of the human eye [J].
Elsheikh, Ahmed ;
Whitford, Charles ;
Hamarashid, Rosti ;
Kassem, Wael ;
Joda, Akram ;
Buechler, Philippe .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (02) :211-216
[10]   Multiparameter Correction Equation for Goldmann Applanation Tonometry [J].
Elsheikh, Ahmed ;
Alhasso, Daad ;
Gunvant, Pinakin ;
Garway-Heath, David .
OPTOMETRY AND VISION SCIENCE, 2011, 88 (01) :E102-E112