Numerical investigation of the energy saving potential of a semi-transparent photovoltaic double-skin facade in a cool-summer Mediterranean climate

被引:200
|
作者
Peng, Jinqing [1 ,2 ]
Curcija, Dragan C. [3 ]
Lu, Lin [2 ]
Selkowitz, Stephen E. [3 ]
Yang, Hongxing [2 ]
Zhang, Weilong [2 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, RERG, Hong Kong, Hong Kong, Peoples R China
[3] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Bldg Technol & Urban Syst Div, 1 Cyclotron Rd, Berkeley, CA 94720 USA
关键词
Building-integrated photovoltaic (BIPV); Energy saving potential; Building energy use; Double-skin facade; Semi-transparent thin-film photovoltaic (STPV); THERMAL PERFORMANCE; OFFICE BUILDINGS; SOLAR-CELLS; PV; WINDOW; BIPV; ELEMENTS; MODULES; INDOOR; INTEGRATION;
D O I
10.1016/j.apenergy.2015.12.074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the annual overall energy performance and energy-saving potential of a ventilated photovoltaic double-skin facade (PV-DSF) in a cool-summer Mediterranean climate zone. A numerical simulation model based on EnergyPlus was utilized to simulate the PV-DSF overall energy performance, simultaneously taking into account thermal power and daylight. Based on numerical model, sensitivity analyses about air gap width and ventilation modes have been lead in Berkeley (California) with the aim to optimize unit's structure design and operational strategy of PV-DSF. Via simulation, the overall energy performance including thermal, power and daylighting of the optimized PV-DSF was evaluated using the typical meteorological year (TMY) weather data. It was found that per unit area of the proposed PV-DSF was able to generate about 65 kW h electricity yearly. If high efficiency cadmium telluride (CdTe) semi-transparent PV modules are adopted, the annual energy output could be even doubled. The PV-DSF studied, also featured good thermal and daylighting performances. The PV-DSF can effectively block solar radiation while still providing considerable daylighting illuminance. Due simply to excellent overall energy performance, a PV-DSF at Berkeley can reduce net electricity use by about 50% compared with other commonly used glazing systems. Efficiency improvements of semi-transparent PV modules would further increase the energy saving potential of a PV-DSF and thus making this technology more promising. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 8 条
  • [1] Developing a method and simulation model for evaluating the overall energy performance of a ventilated semi-transparent photovoltaic double-skin facade
    Peng, Jinqing
    Curcija, Dragan C.
    Lu, Lin
    Selkowitz, Stephen E.
    Yang, Hongxing
    Mitchell, Robin
    PROGRESS IN PHOTOVOLTAICS, 2016, 24 (06): : 781 - 799
  • [2] Energy saving potential of semi-transparent photovoltaic elements for building integration
    Olivieri, L.
    Caamano-Martin, E.
    Moralejo-Vazquez, F. J.
    Martin-Chivelet, N.
    Olivieri, F.
    Neila-Gonzalez, F. J.
    ENERGY, 2014, 76 : 572 - 583
  • [3] Thermal performance evaluation and energy saving potential of semi-transparent CdTe in Facade BIPV
    Alrashidi, Hameed
    Issa, Walid
    Sellami, Nazmi
    Sundaram, Senthilarasu
    Mallick, Tapas
    SOLAR ENERGY, 2022, 232 : 84 - 91
  • [4] Analytical model of semi-transparent photovoltaic double-skin facade system (STPV-DSF) for natural and forced ventilation modes
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    INTERNATIONAL JOURNAL OF VENTILATION, 2023, 22 (02) : 138 - 167
  • [5] Assessment of the inner skin composition impact on the double-skin facade energy performance in the Mediterranean climate
    Khalifa, Ines
    Gharbi-Ernez, Leila
    Znouda, Essia
    Bouden, Chiheb
    8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 : 205 - 214
  • [6] Energy Saving Potential of Double-Skin Facade Buildings with Active Adaptive Operation in Winter
    Wang, Fang
    Zhang, Xiaosong
    Liu, Xiaoqin
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 214 - 221
  • [7] Heating energy savings potential from retrofitting old apartments with an advanced double-skin facade system in cold climate
    Yoon, Yeo Beom
    Seo, Byeongmo
    Koh, Brian Baewon
    Cho, Soolyeon
    FRONTIERS IN ENERGY, 2020, 14 (02) : 224 - 240
  • [8] Examining a numerical model validity for performance evaluation of a prototype solar oriented Double skin Facade: Estimating the technical potential for energy saving
    Radmard, Hamed
    Ghadamian, Hossein
    Esmailie, Fateme
    Ahmadi, Behzad
    Adl, Mehrdad
    SOLAR ENERGY, 2020, 211 : 799 - 809