Application of the insulator coordination gap models and effect of line design to backflashover studies

被引:21
作者
Ab Kadir, M. Z. A. [1 ]
Cotton, I. [2 ]
机构
[1] Univ Putra Malaysia, Dept Elect & Elect Engn, Serdang 43400, Malaysia
[2] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
关键词
Backflashover; Insulation coordination; Coordination gap; Leader progression model; Basic lightning insulation level (BIL);
D O I
10.1016/j.ijepes.2009.09.020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Any insulation coordination study must accurately (or as accurately as possible) express the type and magnitude of all overvoltages on the power system. If these overvoltages are higher than the rating of the equipment, they will result in damage to that equipment. This paper presents the application of the insulator coordination gap models and the effect of line design to the line performance in terms of backflashover rate. The models which are ranging from as simple as voltage controlled switch to as detail as leader progression model will carefully be evaluated. Sensitivity analyses on the effect of line designs such as variation in footing resistance, height of tower/conductor, tower surge impedance and soil resistivity will also be carried out in determining the backflashover rate and the probability of transformer damage by comparing the maximum voltage recorded at the substation entrance with the basic lightning insulation level (BIL). Results will then be compared in finding which model makes the analysis more or less sensitive to any design parameter. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:443 / 449
页数:7
相关论文
共 16 条
[1]  
ABKADIR MZ, 2006, 1 INT POW EN C PECON
[2]  
*BEI, 1991, MOD POW STAT PRACT E, VK
[3]  
Chowdhuri P., 1996, ELECTROMAGNETIC TRAN
[4]  
COTTON I, 2007, EUR T ELECT POWER
[5]   The numerical Laplace transform: An accurate technique for analyzing electromagnetic transients on power system devices [J].
Gomez, Pablo ;
Uribe, Felipe A. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (2-3) :116-123
[6]  
Hileman AndrewR., 1999, Insulation Coordination for Power Systems
[7]  
*IEC, 1993, 711 IEC
[8]  
*IEEE POW ENG SOC, 1997, 12431997 IEEE POW EN
[9]   Modeling guidelines for fast front transients [J].
Imece, AF ;
Durbak, DW ;
Elahi, H ;
Kolluri, S ;
Lux, A ;
Mader, D ;
McDermott, TE ;
Morched, A ;
Mousa, AM ;
Natarajan, R ;
Rugeles, L ;
Tarasiewicz, E .
IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) :493-506
[10]   Simplified model for estimation of lightning induced transient transfer through distribution transformer [J].
Manyahi, MJ ;
Thottappillil, R .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (04) :241-253