Dental Flat Panel Conebeam CT in the Evaluation of Patients with Inflammatory Sinonasal Disease: Diagnostic Efficacy and Radiation Dose Savings

被引:8
|
作者
Leiva-Salinas, C. [1 ,5 ]
Flors, L. [1 ,5 ]
Gras, P. [2 ]
Mas-Estelles, F. [1 ,3 ]
Lemercier, P. [1 ]
Patrie, J. T. [6 ]
Wintermark, M. [5 ]
Marti-Bonmati, L. [1 ,4 ]
机构
[1] Hosp Univ & Politecn La Fe, Dept Radiol & Med Imaging, Valencia, Spain
[2] Hosp Univ & Politecn La Fe, Dept Phys, Valencia, Spain
[3] Hosp Univ & Politecn La Fe, ERESA, Valencia, Spain
[4] Hosp Univ & Politecn La Fe, GIBI Res Grp, Valencia, Spain
[5] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA USA
[6] Univ Virginia, Dept Publ Hlth Sci, Charlottesville, VA USA
关键词
BEAM-COMPUTED-TOMOGRAPHY; PARANASAL SINUSES; MULTIDETECTOR CT; IMAGE QUALITY; REDUCTION; TECHNOLOGY; PRINCIPLES; DOSIMETRY; EXPOSURE; DEVICES;
D O I
10.3174/ajnr.A4019
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. MATERIAL AND METHODS: We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. RESULTS: All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P < .001) and the SNR of the bone was 75% lower (P < .001). The effective dose of our conebeam CT protocol was 23 mu sv. Compared with CT, the absorbed radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P < .001). CONCLUSIONS: Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders.
引用
收藏
页码:2052 / 2057
页数:6
相关论文
共 5 条
  • [1] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Roman Guggenberger
    Erika J. Ulbrich
    Tobias J. Dietrich
    Rosemarie Scholz
    Pascal Kaelin
    Christoph Köhler
    Thilo Elsässer
    Thomas Le Corroller
    Thomas Pfammatter
    Hatem Alkadhi
    Gustav Andreisek
    European Radiology, 2017, 27 : 454 - 463
  • [2] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Guggenberger, Roman
    Ulbrich, Erika J.
    Dietrich, Tobias J.
    Scholz, Rosemarie
    Kaelin, Pascal
    Koehler, Christoph
    Elsaesser, Thilo
    Le Corroller, Thomas
    Pfammatter, Thomas
    Alkadhi, Hatem
    Andreisek, Gustav
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 454 - 463
  • [3] Evaluation of image quality, radiation dose and diagnostic performance of dual-energy CT datasets in patients with hepatocellular carcinoma
    Anzidei, M.
    Di Martino, M.
    Sacconi, B.
    Saba, L.
    Boni, F.
    Zaccagna, F.
    Geiger, D.
    Kirchin, M. A.
    Napoli, A.
    Bezzi, M.
    Catalano, C.
    CLINICAL RADIOLOGY, 2015, 70 (09) : 966 - 973
  • [4] Multi-detector CT enterography in active inflammatory bowel disease: Image quality and diagnostic efficacy of a low-radiation high contrast protocol
    Camera, Luigi
    Pezzullo, Filomena
    Acampora, Angela
    Liuzzi, Raffaele
    Rispo, Antonio
    Nardone, Olga Maria
    Luglio, Gaetano
    Bucci, Luigi
    Castiglione, Fabiana
    Brunetti, Arturo
    CLINICAL IMAGING, 2019, 58 : 27 - 33
  • [5] Effect of Altering Automatic Exposure Control Settings and Quality Reference mAs on Radiation Dose, Image Quality, and Diagnostic Efficacy in MDCT Enterography of Active Inflammatory Crohn's Disease
    Allen, Brian C.
    Baker, Mark E.
    Einstein, David M.
    Remer, Erick M.
    Herts, Brian R.
    Achkar, Jean-Paul
    Davros, William J.
    Novak, Eric
    Obuchowski, Nancy A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 89 - 100