Pulse wave velocity measurement along the ulnar artery in the wrist region using a high-frequency ultrasonic probe with H-topology

被引:0
作者
Benchemoul, Maxime [1 ,2 ]
Mateo, Tony [1 ]
Savery, David [1 ]
Gehin, Claudine [1 ,2 ]
Massot, Bertrand [1 ,2 ]
Ferin, Guillaume [1 ]
Vince, Philippe [1 ]
Flesch, Martin [1 ]
机构
[1] Vermon SA, Act Probe Dept, F-37000 Tours, France
[2] Univ Lyon, INSA Lyon, ECL, CNRS,UCBL,CPE Lyon,INL,UMR5270, F-69621 Villeurbanne, France
来源
INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021) | 2021年
关键词
Pulse wave velocity; pulse transit time; monolithic probe; H-topology; high-frequency; multiplane imaging; superficial arteries; ATHEROSCLEROSIS;
D O I
10.1109/IUS52206.2021.9593834
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cardiovascular diseases (CVD) are considered as the main cause of death representing more than 30% of worldwide casualties according to the World Health Organization [1]. The pulse wave velocity (PWV) is a relevant indicator of CVD [2] at an early stage since it directly reflects the age and stiffness of the arterial network. A PWV measurement method using a high-frequency (15 MHz) ultrasound probe with a H-topology made for vascular imaging is presented in this paper. The probe includes a longitudinal 128-element linear array at the center of the probe and two orthogonal 64-element linear arrays on each side of the probe. This solution makes the probe very well suited to the anatomy of smaller arteries, enabling both longitudinal and cros-ssectional simultaneous imaging of the artery of interest. High frame-rate (HFR) plane wave imaging (10 000 frames per second) is employed for a precise PWV measurement which is performed in-vivo on a healthy volunteer. The long-term objective of this work is to develop an innovative device using a dedicated ultrasonic probe and integrating a miniaturized electronic system. The system would be able to automatically drive the probe, collect data and calculate the PWV in ambulatory situations, on-demand or during periodical routine check-ups. The device would be used at the wrist above the ulnar artery to measure the local PWV.
引用
收藏
页数:4
相关论文
共 18 条
  • [1] [Anonymous], 2014, THESIS
  • [2] Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment
    Avolio, Alberto P.
    Butlin, Mark
    Walsh, Andrew
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (01) : R1 - R47
  • [3] Benchemoul M, 2021, IEEE IUS
  • [4] Assessment of pulse wave velocity
    Boutouyrie P.
    Briet M.
    Collin C.
    Vermeersch S.
    Pannier B.
    [J]. Artery Research, 2009, 3 (1) : 3 - 8
  • [5] Flow-mediated slowing of brachial-radial pulse wave velocity: Methodological aspects and clinical determinants
    Cauwenberghs, Nicholas
    Heyrman, Yenthel
    Thijs, Lutgarde
    Yang, Wen-Yi
    Wei, Fang-Fei
    Zhang, Zhen-Yu
    Staessen, Jan A.
    Kuznetsova, Tatiana
    [J]. ARTERY RESEARCH, 2018, 21 : 29 - 37
  • [6] Measurement of regional pulse wave velocity using very high frame rate ultrasound
    Hasegawa, Hideyuki
    Hongo, Kazue
    Kanai, Hiroshi
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2013, 40 (02) : 91 - 98
  • [7] STUDYING ARTERIAL STIFFNESS USING HIGH-FREQUENCY ULTRASOUND IN MICE WITH ALZHEIMER DISEASE
    Huang, Chin-Chia
    Cheng, Hsiang-Fan
    Zhu, Ben-Peng
    Chen, Pei-Yu
    Beh, Suet Theng
    Kuo, Yu-Min
    Huang, Chih-Chung
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (09) : 2054 - 2064
  • [8] Measurement of pulse wave velocity using pulse wave Doppler ultrasound: Comparison with arterial tonometry
    Jiang, Benyu
    Liu, Baoming
    McNeill, Karen L.
    Chowienczyk, Philip J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03) : 509 - 512
  • [9] Better Management of Cardiovascular Diseases by Pulse Wave Velocity: Combining Clinical Practice with Clinical Research using Evidence-Based Medicine
    Khoshdel, Ali R.
    Carney, Shane L.
    Nair, Balakrishnan R.
    Gillies, Alastair
    [J]. CLINICAL MEDICINE & RESEARCH, 2007, 5 (01) : 45 - 52
  • [10] Interrelationship between non-invasive measurements of atherosclerosis: flow-mediated dilation of brachial artery, carotid intima-media thickness and pulse wave velocity
    Kobayashi, K
    Akishita, M
    Yu, W
    Hashimoto, M
    Ohni, M
    Toba, K
    [J]. ATHEROSCLEROSIS, 2004, 173 (01) : 13 - 18