VUV detection in large-area avalanche photodiodes as a function of temperature

被引:4
作者
Lopes, JAM
Fernandes, LMP
dos Santos, JMF [1 ]
Morgado, RE
Conde, CAN
机构
[1] Univ Coimbra, Dept Fis, P-3004516 Coimbra, Portugal
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
LAAPD; VUV; photon-detection;
D O I
10.1016/S0168-9002(03)00763-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The response of a Peltier-cooled large-area avalanche photodiode to VUV-Iight is investigated as a function of the operation temperature. The reduction of the temperature down to 5degreesC will improve both photodiode light-level detection limit and statistical fluctuations; further temperature reduction will not result in improved performance. Optimum operation characteristics are already achieved for gains around 100 and do not depend significantly on the operation temperature. The relative variation of the gain with temperature increases with the biasing voltage presenting values that are almost a factor of two higher than for visible light detection. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 12 条
[1]  
*ADV PHOT, WIND LARG AR APDS 5
[2]   SOLID-STATE DETECTOR FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL ;
YATES, DA ;
LEVINE, PA ;
SAUER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1231-1239
[3]   Readout of scintillator light with avalanche photodiodes for positron emission tomography [J].
Chen, RR ;
Fremout, A ;
Tavernier, S ;
Bruyndonckx, P ;
Clément, D ;
Loude, JF ;
Morel, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 433 (03) :637-645
[4]   Properties of the most recent avalanche photodiodes for the CMS electromagnetic calorimeter [J].
Deiters, K ;
Musienko, Y ;
Nicol, S ;
Patel, B ;
Renker, D ;
Reucroft, S ;
Rusack, R ;
Sakhelashvili, T ;
Swain, J ;
Vikas, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3) :193-197
[5]   Development of portable gas proportional scintillation counters for x-ray spectrometry [J].
dos Santos, JMF ;
Lopes, JAM ;
Veloso, JFCA ;
Simoes, PCPS ;
Dias, THVT ;
Santos, FP ;
Rachinhas, PJBM ;
Ferreira, LFR ;
Conde, CAN .
X-RAY SPECTROMETRY, 2001, 30 (06) :373-381
[6]   Behaviour of large-area avalanche photodiodes under intense magnetic fields for VUV- visible- and X-ray photon detection [J].
Fernandes, LMP ;
Antognini, A ;
Boucher, M ;
Conde, CAN ;
Huot, O ;
Knowles, P ;
Kottmann, F ;
Ludhova, L ;
Mulhauser, F ;
Pohl, R ;
Schaller, LA ;
dos Santos, JMF ;
Taqqu, D ;
Veloso, JFCA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 498 (1-3) :362-368
[7]   Non-linear behaviour of large-area avalanche photodiodes [J].
Fernandes, LMP ;
Lopes, JAM ;
Monteiro, CMB ;
dos Santos, JMF ;
Morgado, RE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 478 (1-2) :395-399
[8]   Characterization of avalanche photodiodes for calorimetry applications [J].
Karar, A ;
Musienko, Y ;
Vanel, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3) :413-431
[9]   A xenon gas proportional scintillation counter with a UV-sensitive large-area avalanche photodiode [J].
Lopes, JAM ;
dos Santos, JMF ;
Morgado, RE ;
Conde, CAN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :312-319
[10]   An argon gas proportional scintillation counter with UV avalanche photodiode scintillation readout [J].
Monteiro, CMB ;
Lopes, JAM ;
Simoes, PCPS ;
dos Santos, JMF ;
Conde, CAN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1081-1086