Intraaortic balloon pumping for predominantly right ventricular failure after heart transplantation

被引:55
作者
Arafa, OE [1 ]
Geiran, OR
Andersen, K
Fosse, E
Simonsen, S
Svennevig, JL
机构
[1] Univ Oslo, Rikshosp, Dept Thorac & Cardiovasc Surg, N-0027 Oslo, Norway
[2] Univ Oslo, Rikshosp, Dept Cardiol, N-0027 Oslo, Norway
关键词
D O I
10.1016/S0003-4975(00)01864-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Right ventricular failure from elevated pulmonary vascular resistance in the recipient is a main cause of early mortality after heart transplantation. When pharmacologic treatment is insufficient, mechanical circulatory assistance has been used to support the failing right ventricle. Considering right and left ventricular interdependence, we investigated whether intraaortic balloon counterpulsation (IABP) might also alleviate predominantly right ventricular dysfunction after heart transplantation. Methods. Among 278 cardiac recipients, 12 adult patients underwent mechanical circulatory support for cardiac allograft dysfunction. Five patients were treated with percutaneous IABP for early postoperative low cardiac output syndrome characterized by predominantly right ventricular failure. Clinical data and hemodynamic Variables were recorded before and during IABP treatment. Results. Cardiac index (CI) and mean arterial pressure (MAP) increased (CI 1.7 +/- 0.1 to 2.5 +/- 0.2, MAP 53 +/- 12 to 71 +/- 7, p < 0.05) within 1 hour after IABP, whereas central venous pressure (CVP) and pulmonary artery wedge pressure (PAWP) decreased (CVP 21.6 +/- 1.7 to 13.8 +/- 3.1, p <.05; PAWP 14.8 +/- 4.9 to 12.4 +/- 3.7, nonsignificant). Within the next 12 hours, CI and mixed venous oxygen saturation increased (p < 0.05) and pulmonary artery pressure decreased (p < 0.05). All 5 patients were weaned successfully and 4 are long-term survivors with adequate cardiac performance at 1 year follow-up. Conclusions. Intraaortic balloon pumping is a minimally invasive circulatory assist device with proved efficiency in low cardiac output syndromes. This report shows that low output syndrome caused by predominantly right ventricular allograft failure may be an additional indication for IABP. (Ann Thorac Surg 2000;70:1587-93) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1587 / 1593
页数:7
相关论文
共 26 条
  • [21] TASK FORCE-3 - RECIPIENT GUIDELINES PRIORITIZATION
    MUDGE, GH
    GOLDSTEIN, S
    ADDONIZIO, LJ
    CAPLAN, A
    MANCINI, D
    LEVINE, TB
    RITSCH, ME
    STEVENSON, LW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) : 21 - 31
  • [22] HEART-TRANSPLANTATION IN PATIENTS WITH SEVERE PULMONARY-HYPERTENSION AND INCREASED PULMONARY VASCULAR-RESISTANCE
    SIMONSEN, S
    MOLSTAD, P
    GEIRAN, O
    FROYSAKER, T
    [J]. SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 24 (03): : 161 - 164
  • [23] VANTRIGT P, 1995, ANN SURG, V221, P666
  • [24] THE PATHO-PHYSIOLOGY OF FAILURE IN ACUTE RIGHT VENTRICULAR HYPERTENSION - HEMODYNAMIC AND BIOCHEMICAL CORRELATIONS
    VLAHAKES, GJ
    TURLEY, K
    HOFFMAN, JIE
    [J]. CIRCULATION, 1981, 63 (01) : 87 - 95
  • [25] WAHLERS T, 1988, CLIN TRANSPLANT, V2, P252
  • [26] COMPARATIVE SIGNIFICANCE IN SYSTOLIC VENTRICULAR INTERACTION
    YAMAGUCHI, S
    HARASAWA, H
    LI, KS
    ZHU, DL
    SANTAMORE, WP
    [J]. CARDIOVASCULAR RESEARCH, 1991, 25 (09) : 774 - 783