This paper deals with the experimental studies and performance analysis of partially covered hybrid photovoltaic thermal (PVT) flat plate collector (FPC) solar still. The thermal model of the system has been developed. The data have been collected for the composite climate condition of New Delhi. The experimental results have been compared with theoretical results. It has been observed that there is a fair agreement between the experimental and theoretical values with the correlation coefficients varying between 0.97 and 0.99. The coefficient of determination varies between 0.94 and 0.98. The annual productivity has been found to vary between 120.29% and 883.55%. The thermal, exergy and overall thermal efficiency have been evaluated. It has also been observed that the proposed system is self sustainable and it can meet potable water requirement as well as electricity requirement. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:207 / 223
页数:17
相关论文
共 58 条
[21]   Analysis of PV/T flat plate water collectors connected in series [J].
Dubey, Swapnil ;
Tiwari, G. N. .
SOLAR ENERGY, 2009, 83 (09) :1485-1498
[22]   Analytical expression for electrical efficiency of PV/T hybrid air collector [J].
Dubey, Swapnil ;
Sandhu, G. S. ;
Tiwari, G. N. .
APPLIED ENERGY, 2009, 86 (05) :697-705
[23]  
Dwivedi V., 2008, Appl. Sci. Res., V3, P225, DOI [10.3923/tasr.2008.225.241, DOI 10.3923/TASR.2008.225.241]
[24]   Experimental validation of thermal model of a double slope active solar still under natural circulation mode [J].
Dwivedi, V. K. ;
Tiwari, G. N. .
DESALINATION, 2010, 250 (01) :49-55
[25]   Enhancing the solar still performance using solar photovoltaic, flat plate collector and hot air [J].
Eltawil, Mohamed A. ;
Omara, Z. M. .
DESALINATION, 2014, 349 :1-9
[26]   MULTISTAGE, INDIRECTLY HEATED SOLAR-STILL [J].
FERNANDEZ, JL ;
CHARGOY, N .
SOLAR ENERGY, 1990, 44 (04) :215-223
[27]   Performance evaluation of solar photovoltaic/thermal systems [J].
Huang, BJ ;
Lin, TH ;
Hung, WC ;
Sun, FS .
SOLAR ENERGY, 2001, 70 (05) :443-448
[28]   Design and performance of a transportable hemispherical solar still [J].
Ismail, Basel I. .
RENEWABLE ENERGY, 2009, 34 (01) :145-150
[29]   Energetic and exergetic evaluation of flat plate solar collectors [J].
Jafarkazemi, Farzad ;
Ahmadifard, Emad .
RENEWABLE ENERGY, 2013, 56 :55-63
[30]   Experimental investigation of a multi-effect active solar still: The effect of the number of stages [J].
Karimi Estahbanati, M. R. ;
Feilizadeh, Mehrzad ;
Jafarpur, Khosrow ;
Feilizadeh, Mansoor ;
Rahimpour, Mohammad Reza .
APPLIED ENERGY, 2015, 137 :46-55