Profiling human blood serum metabolites by nuclear magnetic resonance spectroscopy: a comprehensive tool for the evaluation of hemodialysis efficiency

被引:8
作者
Kromke, Marika
Palomino-Schaetzlein, Martina
Mayer, Horst
Pfeffer, Stefan
Pineda-Lucena, Antonio
Luy, Burkhard
Hausberg, Martin
Muhle-Goll, Claudia [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Biol Interfaces 4, POB 3640, D-76021 Karlsruhe, Germany
关键词
PATTERN-RECOGNITION METHODS; PROTON NMR-SPECTROSCOPY; STAGE RENAL-DISEASE; BIOMARKER DISCOVERY; PLASMA; METABOLOMICS; DIALYSIS; URINE; UREA; QUANTIFICATION;
D O I
10.1016/j.trsl.2016.02.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Hemodialysis remains the standard therapy to treat patients affected with end-stage renal disease by removing metabolites accumulated in blood plasma. The efficiency of hemodialysis is mainly monitored by urea clearance, which is routinely checked in clinical laboratory practice. However, there is mounting evidence that the clearance behavior of selected single metabolites is not sufficient to predict long-term outcome of treatment. To address this problem, we evaluated the potential of nuclear magnetic resonance spectroscopy for monitoring hemodialysis efficiency by comprehensive profiling of blood serum metabolites. We carried out a pilot study with a cohort of end-stage chronic kidney disease patients (n = 29), analyzing their serum prior and immediately after hemodialysis. To account for supposed variability in the accumulation of metabolites and efficiency of hemodialysis, patients' blood sera were repeatedly collected over a period of several months. Our results revealed that the metabolic profile in terms of concentrations varied considerably between patients but was comparably constant on the patient's level over the period of 4 months. Interestingly, also the individual clearance of the metabolites was characteristic for each patient. Thus, it is conceivable that the observed patient dependent clearance patterns reflect to some extent the patients' long-term perspectives. We conclude that nuclear magnetic resonance spectroscopy is an optimal tool to complement traditional clinical methods based on a single variable, providing comprehensive and much more global information, which is crucial for patient evaluation and the development of improved treatments of kidney failure.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 42 条
  • [1] 1H NMR Spectroscopic Quantification of Plasma Metabolites in Dialysate during Hemodialysis
    Ando, Itiro
    Takeuchi, Kazuhisa
    Oguma, Shiro
    Sato, Hiroshi
    Sekino, Hiroshi
    Imai, Yutaka
    Fujiwara, Masako
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2013, 12 (02) : 129 - 135
  • [2] Accumulation of trimethylamine and trimethylamine-N-oxide in end-stage renal disease patients undergoing haemodialysis
    Bain, MA
    Faull, R
    Fornasini, G
    Milne, RW
    Evans, AM
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (05) : 1300 - 1304
  • [3] Large-scale human metabolomics studies: A strategy for data (pre-) processing and validation
    Bijlsma, S
    Bobeldijk, L
    Verheij, ER
    Ramaker, R
    Kochhar, S
    Macdonald, IA
    van Ommen, B
    Smilde, AK
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (02) : 567 - 574
  • [4] OPLS discriminant analysis:: combining the strengths of PLS-DA and SIMCA classification
    Bylesjo, Max
    Rantalainen, Mattias
    Cloarec, Olivier
    Nicholson, Jeremy K.
    Holmes, Elaine
    Trygg, Johan
    [J]. JOURNAL OF CHEMOMETRICS, 2006, 20 (8-10) : 341 - 351
  • [5] Dialysis modality-dependent changes in serum metabolites: accumulation of inosine and hypoxanthine in patients on haemodialysis
    Choi, Ji-Young
    Yoon, Yoo Jeong
    Choi, Hee-Jeong
    Park, Sun-Hee
    Kim, Chan-Duck
    Kim, In-San
    Kwon, Tae-Hwan
    Do, Jun-Young
    Kim, Sung-Ho
    Ryu, Do Hyun
    Hwang, Geum-Sook
    Kim, Yong-Lim
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (04) : 1304 - 1313
  • [6] Precision High-Throughput Proton NMR Spectroscopy of Human Urine, Serum, and Plasma for Large-Scale Metabolic Phenotyping
    Dona, Anthony C.
    Jimenez, Beatriz
    Schaefer, Hartmut
    Humpfer, Eberhard
    Spraul, Manfred
    Lewis, Matthew R.
    Pearce, Jake T. M.
    Holmes, Elaine
    Lindon, John C.
    Nicholson, Jeremy K.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (19) : 9887 - 9894
  • [7] Plasma and Urinary Amino Acid Metabolomic Profiling in Patients with Different Levels of Kidney Function
    Duranton, Flore
    Lundin, Ulrika
    Gayrard, Nathalie
    Mischak, Harald
    Aparicio, Michel
    Mourad, Georges
    Daures, Jean-Pierre
    Weinberger, Klaus M.
    Argiles, Angel
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2014, 9 (01): : 37 - 45
  • [8] Kinetic behavior of urea is different from that of other water-soluble compounds: The case of the guanidino compounds
    Eloot, S
    Torremans, A
    De Smet, R
    Marescau, B
    De Wachter, D
    De Deyn, PP
    Lameire, N
    Verdonck, P
    Vanholder, R
    [J]. KIDNEY INTERNATIONAL, 2005, 67 (04) : 1566 - 1575
  • [9] Does the Adequacy Parameter Kt/Vurea Reflect Uremic Toxin Concentrations in Hemodialysis Patients?
    Eloot, Sunny
    Van Biesen, Wim
    Glorieux, Griet
    Neirynck, Nathalie
    Dhondt, Annemieke
    Vanholder, Raymond
    [J]. PLOS ONE, 2013, 8 (11):
  • [10] Identification of Cryptic Products of the Gliotoxin Gene Cluster Using NMR-Based Comparative Metabolomics and a Model for Gliotoxin Biosynthesis
    Forseth, Ry R.
    Fox, Ellen M.
    Chung, DaWoon
    Howlett, Barbara J.
    Keller, Nancy P.
    Schroeder, Frank C.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (25) : 9678 - 9681