Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction

被引:3
|
作者
Plachcinska, Anna [1 ]
Wlodarczyk, Michal [2 ]
Kovacevic-Kusmierek, Katarzyna [1 ]
Bienkiewicz, Malgorzata [1 ]
Drozdz, Jaroslaw [3 ]
Chizynski, Krzysztof [4 ]
Kasprzak, Jaroslaw D. [5 ]
Peruga, Jan Z. [5 ]
Kusmierek, Jacek [2 ]
机构
[1] Med Univ Lodz, Interfac Chair Med Imaging & Radiol, Dept Qual Control & Radiol Protect, Lodz, Poland
[2] Med Univ Lodz, Interfac Chair Med Imaging & Radiol, Dept Nucl Med, Lodz, Poland
[3] Med Univ Lodz, Chair Cardiol & Cardiac Surg, Dept Cardiol, Lodz, Poland
[4] Med Univ Lodz, Chair Cardiol & Cardiac Surg, Dept Intens Cardiac Therapy, Lodz, Poland
[5] Med Univ Lodz, Chair Cardiol, Dept Cardiol, Lodz, Poland
关键词
myocardial perfusion imaging; attenuation correction; diagnostic efficacy; 99mTc-MIBI SPECT; CORONARY-ARTERY-DISEASE; MULTICENTER CLINICAL-TRIAL; SPECT; ACCURACY; SCATTER; IMPACT;
D O I
10.5603/KP.a2015.0100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial perfusion single-photon emission computed tomography (SPECT) is one of the basic tools used for the purpose of diagnosis of coronary artery disease (CAD), prognosis of its unfavourable consequences, and evaluation of therapy effectiveness. However, its efficacy is compromised by a relatively low specificity of detection of perfusion defects, which is attributed to attenuation of gamma rays inside the patient's body, causing artefacts erroneously taken for perfusion defects. It is expected that attenuation correction (AC) could eliminate such artefacts. Aim: To evaluate whether visual, semi-quantitative analysis of attenuation-corrected myocardial perfusion imaging provides an advantage over a non-corrected study. Methods: A retrospective study applying AC was performed in 107 patients who had coronary angiography within three months. Patients underwent a stress/rest Tc-99m methoxyisobutylisonitrile (MIBI, POLATOM) double day SPECT/CT myocardial perfusion imaging. Images were analysed by two experienced nuclear medicine specialists (a consensus) applying a visual semiquantitative method. Coronary angiography findings were used as a reference for the analysis of diagnostic performance of myocardial perfusion study protocols. Results: AC increased the specificity of detection of CAD in the whole group of patients from 63% to 86% (p = 0.0005), with a slight reduction in sensitivity (from 83% to 79%). The improved specificity was also noted in subgroups of male and female patients. Accuracy in the whole group of patients increased from 71% to 83% (p = 0.01). AC improved the specificity and accuracy of the method in the detection of perfusion defects in the right coronary artery (RCA) area from 73% to 88% (p = 0.005) and from 74% to 83% (p = 0.04), respectively, and the accuracy of the method in the left anterior descending (LAD) artery area from 79% to 87% (p = 0.043). It also reduced the number of ambiguous results of the study. Conclusions: AC improved the diagnostic performance of myocardial perfusion study in the detection of CAD and identification of critically stenosed LAD and RCA vessels, with enhanced comfort of study interpretation.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [21] Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction
    Zadro, Charline
    Roussel, Noe
    Cassol, Emmanuelle
    Pascal, Pierre
    Petermann, Antoine
    Meyrignac, Olivier
    Jaffro, Marion
    Fournier, Pauline
    Cournot, Maxime
    Galinier, Michel
    Carrie, Didier
    Rousseau, Herve
    Berry, Isabelle
    Lairez, Olivier
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) : 1574 - 1583
  • [22] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [23] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Takayuki Shibutani
    Koichi Okuda
    Hajime Ichikawa
    Toyohiro Kato
    Kenta Miwa
    Hiroyuki Tsushima
    Masahisa Onoguchi
    Akio Nagaki
    Japanese Journal of Radiology, 2020, 38 : 274 - 282
  • [24] Mathematical Modeling of Myocardial Perfusion Diagnosed by the Method of Single-Photon Emission Computed Tomography
    Kolinko, I. P.
    Denisova, N. V.
    Ansheles, A. A.
    TECHNICAL PHYSICS, 2020, 65 (09) : 1436 - 1441
  • [25] Mathematical Modeling of Myocardial Perfusion Diagnosed by the Method of Single-Photon Emission Computed Tomography
    I. P. Kolinko
    N. V. Denisova
    A. A. Ansheles
    Technical Physics, 2020, 65 : 1436 - 1441
  • [26] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Shibutani, Takayuki
    Okuda, Koichi
    Ichikawa, Hajime
    Kato, Toyohiro
    Miwa, Kenta
    Tsushima, Hiroyuki
    Onoguchi, Masahisa
    Nagaki, Akio
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (03) : 274 - 282
  • [27] Procedure guidelines for radionuclide myocardial perfusion imaging with single-photon emission computed tomography
    Arumugam, Parthiban
    Harbinson, Mark
    Reyes, Eliana
    Sabharwal, Nikhant
    Tonge, Christine
    Underwood, Richard
    Kelion, Andrew
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (08) : 813 - 826
  • [28] Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Imaging with Multifocal Collimator
    Takahashi, K.
    Takeuchi, T.
    Hosokai, Y.
    Odagiri, H.
    Usui, A.
    Saito, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S659 - S659
  • [29] Development of attenuation correction methods using deep learning in brain-perfusion single-photon emission computed tomography
    Murata, Taisuke
    Yokota, Hajime
    Yamato, Ryuhei
    Horikoshi, Takuro
    Tsuneda, Masato
    Kurosawa, Ryuna
    Hashimoto, Takuma
    Ota, Joji
    Sawada, Koichi
    Iimori, Takashi
    Masuda, Yoshitada
    Mori, Yasukuni
    Suyari, Hiroki
    Uno, Takashi
    MEDICAL PHYSICS, 2021, 48 (08) : 4177 - 4190
  • [30] Cardiac single-photon emission tomography: is attenuation correction enough?
    Hutton, BF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (07): : 713 - 715