High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry

被引:58
作者
Staerk, U [1 ]
Külpmann, WR [1 ]
机构
[1] Med Univ, D-30625 Hannover, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 745卷 / 02期
关键词
solid-phase microextraction; drugs;
D O I
10.1016/S0378-4347(00)00312-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove Lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 mu g/l), barbiturates (500 mu g/l), benzodiazepines (100 mu g/l), benzoylecgonine (150 mu g/l), methadone (100 mu g/l) and opiates (200 mu g/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:399 / 411
页数:13
相关论文
共 32 条
  • [31] Solid-phase microextraction with capillary gas-liquid chromatography and nitrogen-phosphorus selective detection for the assay of antidepressant drugs in human plasma
    Ulrich, S
    Martens, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (02): : 217 - 234
  • [32] Detection of amphetamines in urine using head space solid phase microextraction and chemical ionization selected ion monitoring
    Yashiki, M
    Kojima, T
    Miyazaki, T
    Nagasawa, N
    Iwasaki, Y
    Hara, K
    [J]. FORENSIC SCIENCE INTERNATIONAL, 1995, 76 (03) : 169 - 177