High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry

被引:58
作者
Staerk, U [1 ]
Külpmann, WR [1 ]
机构
[1] Med Univ, D-30625 Hannover, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 745卷 / 02期
关键词
solid-phase microextraction; drugs;
D O I
10.1016/S0378-4347(00)00312-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove Lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 mu g/l), barbiturates (500 mu g/l), benzodiazepines (100 mu g/l), benzoylecgonine (150 mu g/l), methadone (100 mu g/l) and opiates (200 mu g/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:399 / 411
页数:13
相关论文
共 32 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Quantitative and qualitative analysis of MDMA, MDEA, MA and amphetamine in urine by head-space/solid phase micro-extraction (SPME) and GC/MS [J].
Centini, F ;
Masti, A ;
Comparini, IB .
FORENSIC SCIENCE INTERNATIONAL, 1996, 83 (03) :161-166
[3]   GAS-CHROMATOGRAPHIC ANALYSIS OF METHADONE IN URINE SAMPLES AFTER SOLID-PHASE MICROEXTRACTION [J].
CHIAROTTI, M ;
MARSILI, R .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (06) :577-580
[4]  
Chiarotti M, 1997, J MICROCOLUMN SEP, V9, P249, DOI 10.1002/(SICI)1520-667X(1997)9:4<249::AID-MCS1>3.3.CO
[5]  
2-S
[6]   Comparison of new solid-phase extraction methods for chromatographic identification of drugs in clinical toxicological analysis [J].
Degel, F .
CLINICAL BIOCHEMISTRY, 1996, 29 (06) :529-540
[7]   Recommendations for the reliable detection of illicit drugs in urine in the European Union, with special attention to the workplace [J].
delaTorre, R ;
Segura, J ;
deZeeuw, R ;
Williams, J ;
Worm, K ;
Aguado, R ;
Badia, R ;
Brenneisen, R ;
deZeeuw, RA ;
Olesen, H ;
Rohde, M ;
Queralto, JM .
ANNALS OF CLINICAL BIOCHEMISTRY, 1997, 34 :339-344
[8]   Determination of barbiturates by solid-phase microextraction (SPME) and ion trap gas chromatography mass spectrometry [J].
Hall, BJ ;
Brodbelt, JS .
JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (02) :275-282
[9]   Simple extraction of phencyclidine from human body fluids by headspace solid-phase microextraction (SPME) [J].
Ishii, A ;
Seno, H ;
Kumazawa, T ;
Watanabe, K ;
Hattori, H ;
Suzuki, O .
CHROMATOGRAPHIA, 1996, 43 (5-6) :331-333
[10]   Determination of amphetamine and methamphetamine in human hair by headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection [J].
Koide, I ;
Noguchi, O ;
Okada, K ;
Yokoyama, A ;
Oda, H ;
Yamamoto, S ;
Kataoka, H .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :99-104