Optimizing cuff width for noninvasive measurement of blood pressure

被引:52
|
作者
Marks, LA
Groch, A
机构
[1] St Christophers Hosp Children, Philadelphia, PA 19133 USA
[2] Temple Univ, Sch Med, Philadelphia, PA 19122 USA
[3] Univ Med & Dent New Jersey, Newark, NJ 07103 USA
关键词
blood pressure; blood pressure determination; hemodynamics; hypertension;
D O I
10.1097/00126097-200006000-00002
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background It is well established that indirect measurements of blood pressure made with a standard 13 cm-wide cuff are erroneously high for large arms and low for small arms. To correct for this error, the American Heart Association recommends adjusting cuff width to 40% of the arm's circumference, Objective To test the validity of this method of correction. Design This study was a prospective, nonblinded, paired Student's t-test analysis. Methods Blood pressures in 50 subjects were measured directly by using a radial artery line and indirectly by the Korotkov method. For each subject multiple indirect measurements of blood pressure were made with the cuff width:arm circumference ratio varied from 30-55% in 5% increments. Error was defined as indirect blood pressure minus direct blood pressure. Results A ratio of 40% resulted in overestimation of blood pressure for most arms and with particularly high errors for small arms. The ratio producing zero mean error for the pooled study group was 46.4 +/- 0.7% (mean +/- SEM). Using this ratio of 46.4%, the error varied inversely with arm circumference (P < 0.02), resulting in overestimation of systolic blood pressure for small arms and underestimation of systolic blood pressure for large arms. This error is comparable in magnitude, but opposite in sign, to that which occurs with a standard 13 cm-wide cuff for all arms. The optimum ratio was found to be closely approximated by the relationship, cuff width = 9.34 log(10) arm circumference. Using this relationship, error in systolic blood pressure was insensitive to arm circumference (r = 0.04, P > 0.05) and near zero. Conclusion The optimum cuff width for the indirect measurement of blood pressure is not directly proportional to arm circumference, but is proportional to the logarithm of the arm's circumference. Blood Press Monit 5:153-158 (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [21] The influence of cuff size on blood pressure measurement
    Bakx, C
    Oerlemans, G
    vandenHoogen, H
    vanWeel, C
    Thien, T
    JOURNAL OF HUMAN HYPERTENSION, 1997, 11 (07) : 439 - 445
  • [22] Pitfalls of Cuff Size and Blood Pressure Measurement
    Zuin, Marco
    Rigatelli, Gianluca
    JAMA INTERNAL MEDICINE, 2024, 184 (04) : 448 - 448
  • [23] Blood pressure measurement using finger cuff
    Lee, J. Y.
    Choi, E. Y.
    Jeong, H. J.
    Kim, K. H.
    Park, J. C.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3575 - 3577
  • [24] The influence of cuff size on blood pressure measurement
    C Bakx
    G Oerlemans
    H van den Hoogen
    C van Weel
    T Thien
    Journal of Human Hypertension, 1997, 11 : 439 - 445
  • [25] CUFF PRESSURE OSCILLATIONS IN MEASUREMENT OF RELATIVE BLOOD-PRESSURE
    GEDDES, LA
    NEWBERG, DC
    PSYCHOPHYSIOLOGY, 1977, 14 (02) : 198 - 202
  • [26] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [27] Numerical simulation of noninvasive blood pressure measurement
    Hayashi, Satoru
    Hayase, Toshiyuki
    Shirai, Atsushi
    Maruyama, Masaru
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05): : 680 - 687
  • [28] Automatic Noninvasive Measurement of Arterial Blood Pressure
    Nitzan, Meir
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2011, 14 (01) : 32 - 37
  • [29] Dual-cuff System Improves Noninvasive Blood Pressure Determination
    Jilek, Jiri
    Stork, Milan
    2010 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2010, : 145 - 148
  • [30] Physical Noninvasive Attacks on Photoplethysmogram by Computer Controlled Blood Pressure Cuff
    Yoshida, Kazuki
    Sawano, Ryota
    Okamoto, Masahiro
    Murao, Kazuya
    Tsuchida, Shuhei
    Terada, Tsutomu
    Tran, Yvonne
    SENSORS, 2023, 23 (24)