Experimental studies on screw connections between cold-formed steel framing and sandwich sheathing

被引:5
作者
Jammi, Ashok [1 ]
Jayachandran, S. Arul [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Madras 600036, Tamil Nadu, India
关键词
Cold formed steel; Screw connections; Sandwich sheathing; Ductility; Pinched hysteresis; BEHAVIOR; DESIGN;
D O I
10.1016/j.istruc.2021.02.066
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold formed steel (CFS) framed wall panels with sheathing is one of the main lateral load resisting systems in light gauge structures. The nonlinear behavior of the CFS wall panel under in-plane shear loading is dictated by the nonlinear behavior of the screw connections between CFS framing and sheathing. Necessity for new and high performance CFS shear wall configurations is clearly felt by the engineering community in order to cater for the increased seismic demands in mid-rise CFS buildings. To this end the experimental studies on screw connections are essential to understand the behavior of full scale wall panels by phenomenological models. This paper presents the experimental studies on the screw connection between CFS framing and new sheathing configuration with screw subjected to shear parallel to the free edge of the sheathing. This setup mimics shear experienced by the screw as a component in full scale wall panel tests. The proposed new sheathing configuration consists of a brittle sheathing material (one of cement particle board, fiber cement board and gypsum wallboard) sandwiched between two thin steel sheets. The experiments are performed for both monotonic and cyclic loading protocols and the stiffness, ultimate strength and ductility showed a significant increase due to the sandwich steel sheets. Ultimately, the configuration with sheathing material which provides higher strength as well as ductility has been proposed for future study by full scale experiments.
引用
收藏
页码:2048 / 2059
页数:12
相关论文
共 35 条
  • [1] [Anonymous], 2019, AD100210 ASTM
  • [2] Bostik-No More Nails, 2016, SOLVENT BASED CONSTR
  • [3] Light-gauge steel-frame - wood structural panel shear wall design method
    Branston, A. E.
    Boudreault, F. A.
    Chen, C. Y.
    Rogers, C. A.
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (07) : 872 - 889
  • [4] Bryan ER, 1975, INT SPEC C COLD FORM, P3
  • [5] Computationally efficient fastener-based models of cold-formed steel shear walls with wood sheathing
    Buonopane, S. G.
    Bian, G.
    Tun, T. H.
    Schafer, B. W.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 110 : 137 - 148
  • [6] CEN (European Committee for Standardization), 2008, EN199511 CEN
  • [7] Experimental tests on typical screw connections for cold-formed steel housing
    Fiorino, L.
    Della Corte, G.
    Landolfo, R.
    [J]. ENGINEERING STRUCTURES, 2007, 29 (08) : 1761 - 1773
  • [8] Evaluation of seismic dynamic behaviour of drywall partitions, facades and ceilings through shake table testing
    Fiorino, Luigi
    Bucciero, Bianca
    Landolfo, Raffaele
    [J]. ENGINEERING STRUCTURES, 2019, 180 : 103 - 123
  • [9] Experimental study on screwed connections for sheathed CFS structures with gypsum or cement based panels
    Fiorino, Luigi
    Pali, Tatiana
    Bucciero, Bianca
    Macillo, Vincenzo
    Terracciano, Maria Teresa
    Landolfo, Raffaele
    [J]. THIN-WALLED STRUCTURES, 2017, 116 : 234 - 249
  • [10] Cyclic analysis of wood shear walls
    Folz, B
    Filiatrault, A
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2001, 127 (04): : 433 - 441