A simple paper-based colorimetric analytical device for rapid detection of Enterococcus faecalis under the stress of chlorophenols

被引:15
|
作者
Sun, Qidi [1 ]
Tam, Nora F. Y. [1 ,2 ]
Han, Jie [2 ]
Peng, Will Yung-Kang [1 ]
Zhu, Zonglong [1 ]
Chen, Jian Lin [1 ,2 ]
机构
[1] City Univ Hong Kong, Dept Chem, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
[2] Open Univ Hong Kong, Sch Sci & Technol, Dept Sci, Ho Man Tin, Good Shepherd St, Hong Kong, Peoples R China
关键词
Resazurin; Toxicity; PAD; Bacteria detection; Enterococcus faecalis; Pentachlorophenol; ANAEROBIC-DIGESTION; TOXICITY; ASSAY; IDENTIFICATION; TOXICANTS; BACTERIA; EC50;
D O I
10.1016/j.talanta.2020.121966
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bacteria detection and toxicity measurement are essential in many aspects. Becoming increasingly popular in recent years, paper-based analytical devices (PADs) have proven to be cost-effective, portable and eco-friendly with quantitative diagnostic results. In this work, by a straightforward soaking-drying method, a resazurin-deposited PAD has been developed for rapid bacteria detection and biotoxicity measurement. The colorimetric response on the PAD was generated from metabolic reduction of resazurin by Enterococcus faecalis, a facultative anaerobic bacterial strain. After recording and quantifying the colorimetric response with Hue value by a smartphone, the bioassay on PAD enables the detection of resazurin reduction kinetics difference among bacteria at various densities in 10 min. Thereby, the bioassay on PAD was applied to study the toxicity of two chlorophenols, i.e. pentachlorophenol (PCP) and 4-chlorophenol (4-CP), to E. faecalis. Compared to growth-based inhibition test, which takes 5 h, this assay shows higher efficiency, i.e. in 30 min, the biotoxicity difference between PCP and 4-CP can be identified.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Paper-Based Enzymatic Colorimetric Assay for Rapid Malathion Detection
    Jian-Hui Li
    Xue-Lei Deng
    Yu-Lian Zhao
    Xiao-Yan Zhang
    Yun-Peng Bai
    Applied Biochemistry and Biotechnology, 2021, 193 : 2534 - 2546
  • [32] Paper-Based Enzymatic Colorimetric Assay for Rapid Malathion Detection
    Li, Jian-Hui
    Deng, Xue-Lei
    Zhao, Yu-Lian
    Zhang, Xiao-Yan
    Bai, Yun-Peng
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2021, 193 (08) : 2534 - 2546
  • [33] Simple and inexpensive electrochemical paper-based analytical device for sensitive detection of Pseudomonas aeruginosa
    Ferreira e Silva, Rafael
    Longo Cesar Paixao, Thiago Regis
    Torossian Torres, Marcelo Der
    de Araujo, William Reis
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 308
  • [34] Colorimetric detection of solution concentration based on a paper-based microfluidic device
    Dong, Liangwei
    Hu, Yueli
    Chen, Xiuyu
    Liu, Xiajun
    MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [35] Paper-based analytical device with colorimetric detection for urease activity determination in soils and evaluation of potential inhibitors
    Tavares, Maria Celia
    Oliveira, Karoliny Almeida
    de Fatima, Angelo
    Coltro, Wendell K. T.
    Caldas Santos, Josue Carinhanha
    TALANTA, 2021, 230
  • [36] Microfluidic paper-based analytical device integrated with Fe@ZnS:MIP for colorimetric detection of antibiotics
    Riaz A.
    Zareef I.
    Munawar A.
    Rakha A.
    Khan M.F.
    Akhtar S.
    Anwar A.
    Nazir S.
    Din S.
    Abbasi A.S.
    Applied Nanoscience (Switzerland), 2023, 13 (09): : 6331 - 6339
  • [37] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21
  • [38] Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine
    Zhang, Han
    Smith, Ethan
    Zhang, Wei
    Zhou, Anhong
    BIOMEDICAL MICRODEVICES, 2019, 21 (03)
  • [39] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Taghizadeh-Behbahani, Maryam
    Hemmateenejad, Bahram
    Shamsipur, Mojtaba
    CHEMICAL PAPERS, 2018, 72 (05) : 1239 - 1247
  • [40] Paper-based analytical device for sensitive colorimetric determination of sulfonamides in pharmaceutical samples
    Jabbar, Hijran Sanaan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 304