Velocity profile of red blood cells in human retinal vessels using confocal scanning laser Doppler velocimetry

被引:0
|
作者
Logean, E [1 ]
Schmetterer, L
Riva, CE
机构
[1] Inst Rech Ophtalmol, Sion, Switzerland
[2] Univ Vienna, Inst Med Phys, Vienna, Austria
[3] Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
[4] Univ Lausanne, Fac Med, Lausanne, Switzerland
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new method to measure red blood cell velocity profiles in retinal vessels is presented. It is based on the well-established laser Doppler velocimetry with lasers of long coherence length. A confocal arrangement is used for the delivery of a narrow probing beam (diameter at the fundus of about 1/10 the vessel diameter) and the detection of the light scattered by the red blood cells (RBCs). The velocity profile of the RBCs at arterial and venous sites of the major retinal vessels is derived from scans of the probing laser across these vessels. In vitro experiments demonstrate the performance of the instrument. Measurements of arterial velocity profiles obtained at both the systolic and diastolic phases of the cardiac cycle, as well as nonsymmetric profiles determined at different distances downstream from a venous Junction, are reported for the human organism for the first time. The wall shear rates calculated from these profiles are in good agreement with data derived from experiments in animals.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [41] Noninvasive imaging and velocimetry of human retinal blood flow using color Doppler optical coherence tomography
    Yazdanfar, S
    Rollins, AM
    Izatt, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S548 - S548
  • [42] VALIDATION AND REPRODUCIBILITY OF BIDIRECTIONAL LASER DOPPLER VELOCIMETRY FOR THE MEASUREMENT OF RETINAL BLOOD-FLOW
    DAVIES, EG
    SULLIVAN, PM
    FITZPATRICK, M
    KOHNER, EM
    CURRENT EYE RESEARCH, 1992, 11 (07) : 633 - 640
  • [43] A LASER DOPPLER VELOCIMETRY STUDY OF THE EFFECT OF HYPOGLYCEMIA ON RETINAL BLOOD-FLOW IN THE MINIPIG
    CALDWELL, G
    DAVIES, EG
    SULLIVAN, PM
    MORRIS, AHC
    KOHNER, EM
    DIABETOLOGIA, 1990, 33 (05) : 262 - 265
  • [44] New ray tracing model for the estimation of power spectral properties in laser Doppler velocimetry of retinal vessels
    Petrig, BL
    Follonier, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [45] MEASUREMENT OF BLOOD VELOCITY IN CORONARY-ARTERY BY THE LASER DOPPLER VELOCIMETRY WITH AN OPTICAL FIBER
    TOMONAGA, G
    HOKI, N
    KAJIYA, F
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1980, 44 (08): : 631 - 632
  • [46] Blood flow velocity imaging of malignant melanoma by micro multipoint laser Doppler velocimetry
    Ishida, H.
    Andoh, T.
    Akiguchi, S.
    Shirakawa, H.
    Kobayashi, D.
    Kuraishi, Y.
    Hachiga, T.
    APPLIED PHYSICS LETTERS, 2010, 97 (10)
  • [47] Me effect of pure oxygen on retinal blood flow in the cat using a new laser Doppler velocimetry system
    Kagokawa, H
    Sakamoto, T
    Takakusaki, K
    Ogasawara, H
    Yoshida, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3622 - 3622
  • [48] Measurement of oxygen saturation in small retinal vessels with adaptive optics confocal scanning laser ophthalmoscope
    Li, Hao
    Lu, Jing
    Shi, Guohua
    Zhang, Yudong
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
  • [49] MEASUREMENT OF VELOCITY PROFILES OF RED BLOOD-CELLS IN MICROCIRCULATION BY LASER DOPPLER ANEMOMETRY (LDA)
    EINAV, S
    BERMAN, HJ
    FUHRO, RL
    DIGIOVANNI, PR
    FINE, S
    FRIDMAN, JD
    BIORHEOLOGY, 1975, 12 (3-4) : 207 - 210
  • [50] Characterization of malaria infected red blood cells by scanning confocal laser and acoustic vector contrast microscopy
    Mohamed, E. T. Ahmed
    Schubert, S.
    Gilberger, T. W.
    Kamanyi, A.
    Wannemacher, R.
    Grill, W.
    HEALTH MONITORING AND SMART NONDESTRUCTIVE EVALUATION OF STRUCTURAL AND BIOLOGICAL SYSTEMS V, 2006, 6177