Intra-oral laser welding: an in vitro evaluation of thermal increase

被引:11
作者
Fornaini, C. [1 ,2 ,3 ]
Bertrand, C. [2 ]
Rocca, J. P. [2 ]
Mahler, P. [2 ]
Bonanini, M. [3 ]
Vescovi, P. [3 ]
Merigo, E. [3 ]
Nammour, S. [1 ]
机构
[1] Univ Liege, Dept Dent Sci, Fac Med, Liege, Belgium
[2] Univ Nice Sophie Antipolis, Nice, France
[3] Univ Parma, I-43100 Parma, Italy
关键词
Neodymium:yttrium-aluminium-garnet (Nd:YAG) laser; Temperature increase; Thermocouple; Laser welding; Intra-oral welding; Jaws; FIXED PARTIAL DENTURES; ND-YAG LASER; TITANIUM; ALLOY;
D O I
10.1007/s10103-009-0666-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The neodymium:yttrium-aluminium-garnet (Nd:YAG) laser is currently used in dental laboratories to weld metals on dental prostheses. Recently, the use of Nd:YAG has been suggested so that dentists themselves can repair broken fixed, removable and orthodontic prostheses by welding metals directly in the mouth. This work aimed to evaluate, through a four k-type thermocouple system on calf jaws, the thermal increase in the biological structures close to the metal parts during laser welding. We put two hemispherical metal plates onto mandibular molars and then laser welded them at three points with a four k-thermocouple system to determine the thermal rise in the pulp chamber, sulcus, root and bone. This procedure was carried out on 12 samples, and the results were processed. The highest values of thermal increase were found in the pulp chamber, 1.5A degrees C; sulcus, 0.7A degrees C; root, 0.3A degrees C; and bone, 0.3A degrees C. This study showed that thermal increases in pulp chamber, sulcus, root and bone were biologically compatible and that intra-oral laser welding, at the parameters used in this work, seems to be harmless to the biological structures close to the welding and thermally affected zones.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 35 条
[1]  
[Anonymous], WELD INT
[2]   LASER-WELDED VS SOLDERED NONPRECIOUS ALLOY DENTAL BRIDGES - A COMPARATIVE-STUDY [J].
APOTHEKER, H ;
NISHIMURA, I ;
SEERATTAN, C .
LASERS IN SURGERY AND MEDICINE, 1984, 4 (02) :207-213
[3]  
ASIN M, 2008, IMPLANTOLOGIE REV CH, V6, P7
[4]   MECHANICAL-PROPERTIES OF LASER-WELDED CAST AND WROUGHT TITANIUM [J].
BERG, E ;
WAGNER, WC ;
DAVIK, G ;
DOOTZ, ER .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (03) :250-257
[5]  
BERTELE G, 2006, EUR J IMPLANT PROSTH, V2, P65
[6]   Optimization of operator and physical parameters for laser welding of dental materials [J].
Bertrand, C ;
le Petitcorps, Y ;
Albingre, L ;
Dupuis, V .
BRITISH DENTAL JOURNAL, 2004, 196 (07) :413-418
[7]   The laser welding technique applied to the non precious dental alloys procedure and results [J].
Bertrand, C ;
Le Petitcorps, Y ;
Albingre, L ;
Dupuis, V .
BRITISH DENTAL JOURNAL, 2001, 190 (05) :255-257
[8]  
Borgstedt T, 1991, Dent Labor (Munch), V39, P1205
[9]  
Cary H.B., 2002, Modern Welding Technology
[10]   A PRELIMINARY-STUDY ON THE EFFECTS OF THE NDYAG LASER ON ROOT SURFACES AND SUBGINGIVAL MICROFLORA INVIVO [J].
COBB, CM ;
MCCAWLEY, TK ;
KILLOY, WJ .
JOURNAL OF PERIODONTOLOGY, 1992, 63 (08) :701-707