Winner of the 2003 James A. Rand Young investigator's award

被引:40
作者
Barrack, RL [1 ]
Nakamura, SJ [1 ]
Hopkins, SG [1 ]
Rosenzweig, S [1 ]
机构
[1] Tulane Univ, Hlth Sci Ctr, Dept Orthopaed Surg, New Orleans, LA 70118 USA
关键词
total knee arthroplasty; cementless; mobile-bearing;
D O I
10.1016/j.arth.2004.06.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A consecutive series of 82 cementless mobile-bearing total knee arthroplasties performed was studied to determine the reliability of cementless tibial component fixation. The indications for surgery in all cases were osteoarthritis with only mild or moderate deformity. Evaluation consisted of a Knee Society clinical score (KSCS) and radiographic evaluation preoperatively and at annual follow-up. Minimum 2-year follow-up was obtained in 73 4,82 knees (89%). Results were compared to those of a subsequent consecutive series of 76 knees (66 with 2-year follow-up) performed with a mobile-bearing TKA with cemented components with the same indications, implant, technique, and length of follow-up. Six of 73 cementless mobile-bearing TKAs (8%) underwent tibial component revision for symptomatic Subsidence and failure of ingrowth compared to 0/66 revisions in the cemented group (P<.05). Patients with cementless mobile-bearing TKA also had a significantly lower KSCS (161 versus 184, P<.05), significantly higher incidence of pain rated more than mild (23% versus 7%, P<.01) and a trend toward less arc of motion (1060 versus 115degrees, <.2). The results do not support the hypothesis that mobile-bearing TKA imparts the advantage of reliable tibial bone ingrowth. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:101 / 106
页数:6
相关论文
共 20 条
[1]  
Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
[2]  
Callaghan J J, 2001, Instr Course Lect, V50, P431
[3]   Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[4]  
Callaghan JJ, 2001, CLIN ORTHOP RELAT R, P221
[5]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
[6]  
COOK SD, 1989, J ARTHROPLASTY S, V4, P33
[7]   In vivo deterioration of tibial baseplate locking mechanisms in contemporary modular total knee components [J].
Engh, GA ;
Lounici, S ;
Rao, AR ;
Collier, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) :1660-1665
[8]  
Fehring TK, 2001, CLIN ORTHOP RELAT R, P315
[9]   Range of motion of posterior-cruciate-substituting total knee replacements: The effect of bearing mobility [J].
Haas, B ;
Dennis, DA ;
Komistek, RD ;
Brumley, JT ;
Hammill, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A :51-55
[10]   Low contact stress mobile bearing total knee arthroplasty - Results at 5 to 13 Years [J].
Hartford, JM ;
Hunt, T ;
Kaufer, H .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :977-983